All MIBs › OMNITRON-MIB
Organization: Omnitron Systems Technology, Inc.
Last Updated: 2015-10-21
Category: Media Converters
Description: Provides SNMP management objects for Omnitron Systems Technology fiber-to-copper media converter devices.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNITRON-MIB?
This is Omnitron Systems Technology's private MIB for its iConverter line of fiber-to-copper media converter chassis and modules, managed via the NetOutlook application. It exposes hardware inventory and chassis data, chassis/slot numbering, chassis type, product type, product name, part number, serial number, and manufacture date, essentially asset and identity information for each installed media-converter module. This directly supports monitoring hardware status: administrators can confirm which converter modules are physically present in each chassis slot, verify serial/part numbers for warranty or replacement purposes, and detect when a module is missing or has been swapped. It's a self-contained vendor MIB with no apparent dependency on external standard MIBs beyond usual SNMPv2-SMI framework conventions. It is typically deployed in metro/enterprise fiber networks where Omnitron iConverter chassis provide media conversion and need centralized hardware-inventory monitoring. Network engineers evaluating or troubleshooting this functionality can download the OMNITRON-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNITRON-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Omnitron iConverter media converter chassis
- fiber-to-copper media converter module
Monitoring Examples
An administrator polls chassisTable / chassisEntry, indexed by chassisnum and slotnum, to read chassistype, prodtype, chassisname, partnum, and serialnum for each installed module, confirming the expected hardware is present in every slot. A slot returning no entry or an unexpected prodtype/serialnum would indicate a missing, failed, or replaced media-converter module needing physical verification.
What Can Be Monitored
- chassis/slot inventory
- product type per slot
- serial number
- part number
- manufacture date
This MIB depends on
Related MIBs
Imported Objects
From OMNITRON-TC-MIB
| OstModeType | |
| OstPortList | |
| OstPortNumber | |
| OstVlanId | |
| icAgent | OBJECT-IDENTITY |
| omnitron | OBJECT-IDENTITY |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Counter32 | |
| Counter64 | |
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| OBJECT-TYPE | |
| Unsigned32 |
From SNMPv2-TC
| DisplayString | |
| TimeInterval | |
| TruthValue |
How to Use in IPNetwork Monitor
Example using txOctets OID:
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| chassisTable | 1.3.6.1.4.1.7342.1.1 | not-accessible | This a table of chassis and their modules. | |
| chassisEntry | 1.3.6.1.4.1.7342.1.1.1 | not-accessible | Chassis modules. | |
| I32 chassisnum | 1.3.6.1.4.1.7342.1.1.1.1 | Integer32 | read-only | The chassis where the module resides. Ranges in value from 1 - 19. |
| I32 slotnum | 1.3.6.1.4.1.7342.1.1.1.2 | Integer32 | read-only | The slot number of the module. For the 19 slot chassis it ranges in value from 1-22. For the 2 slot chassis it ranges in value from 1-2. |
| I32 chassistype | 1.3.6.1.4.1.7342.1.1.1.3 | Integer32 | read-only | Type of chassis: 1 = 19 module chassis 2 = 2 module chassis 3 = 5 module chassis 4 = 1 module chassis 5 = stand alone chassis 6 = 1-module redundant power chassis |
| I32 prodtype | 1.3.6.1.4.1.7342.1.1.1.4 | Integer32 | read-only | The product type of the module: 61 = iConverter NMM 64 = iConverter Power Supply (19 Module) 65 = iConverter 10FL/T Ethernet 66 = iConverter 100 Fx/Tx Ethernet 67 = iConverter Fiber/Fiber 68 = iConverter 10/100 Ethernet 70 = iConverter 2FXM slave 72 = iConverter GX/X 74 = iConverter Tx/2Tx Ethernet 75 = iConverter Gx Gigabit Ethernet 76 = iConverter Tx/2Fx Ethernet 77 = iConverter T1/E1 79 = iConverter 4Tx Ethernet 80 = iConverter 10/100M 81 = iConverter GX/T Ethernet 82 = iConverter Power Supply (5 Module) 83 = iConverter GX/F Ethernet 84 = iConverter 2FX Ethernet 85 = iConverter 10T/2 Ethernet 86 = iConverter 10/100VT Ethernet 87 = iConverter 4Tx VT 88 = iConverter RS 422/485 89 = iConverter T3/E3 90 = iConverter 10/100M slave 92 = iConverter RS 232 93 = iConverter GX/TM 94 = iConverter GX/TM slave 95 = iConverter 2GXM 96 = iConverter 2FXM 97 = iConverter GM3 2xSFP 98 = iConverter 2GXM slave 99 = iConverter GM3 2xUTP 100= iConverter 10/100M2 101= iConverter 2FXM2 102= iConverter GM3 SFP/2xUTP 103= iConverter 1-Module Redundant Powered Chassis 104= iConverter Gx AN 105= iConverter GX/TM2 106= iConverter 2GX/TM2 107= iConverter 4xT1/E1 Mux 108= iConverter GM3 2xSFP/UTP 109= iConverter GM3 3xSFP 110= iConverter X.21 112= iConverter GM3 3xUTP 113= iConverter GM3 FF/UTP or SFP/UTP 114= iConverter CWDM 115= iConverter XG 117= iConverter TM3 119= iConverter 4GT 120= iConverter GM4 2xSFP/TP 136= iConverter XGT+ 137= iConverter GM4 5-Port 142= iConverter GX/T2 143= iConverter GM4-HPoE or GM4-PoE+ 253= iConverter GM3 2XSFP 254= iConverter GM3 1xSFP/2xUTP 255= iConverter Unknown |
| STR chassisname | 1.3.6.1.4.1.7342.1.1.1.5 | DisplayString | read-write | The name of the chassis. For the M2 modules the max size is 32 octets. For the GM3, GM4, XM5 the max size is 64 octets when a module is accessed directly through the serial port, or via its own IP address for Telnet, SSH, or SNMP. For the GM3, GM4, XM5 when the object is indirectly accessed via the backplane, through IP-less, or through 802.3ah peer-to-peer the value is truncated to 32 bytes. |
| STR partnum | 1.3.6.1.4.1.7342.1.1.1.6 | DisplayString | read-only | The part number of the module. |
| STR serialnum | 1.3.6.1.4.1.7342.1.1.1.7 | DisplayString | read-only | The serial number of the module. |
| STR manufdate | 1.3.6.1.4.1.7342.1.1.1.8 | DisplayString | read-only | The date the module was manufactured in form YYYYMMDD. |
| I32 softrev | 1.3.6.1.4.1.7342.1.1.1.9 | Integer32 | read-only | The software revision of the module software. |
| I32 prodrev | 1.3.6.1.4.1.7342.1.1.1.10 | Integer32 | read-only | The product revision of the module. |
| I32 ledstat | 1.3.6.1.4.1.7342.1.1.1.11 | Integer32 | read-only | The status of any first 32 LEDs on the module, excluding the power LED. If an LED is missing its number is skipped. For an eight LED position device the following is the decoding: ledstat.7 is the top LED position ledstat.6 is the second LED position ledstat.5 is the third LED position ledstat.4 is the fourth LED position ledstat.3 is the fifth LED position ledstat.2 is the sixth LED position ledstat.1 is the seventh LED position ledstat.0 is the eighth and bottom LED position For devices that have 32 or less LEDs this object contains all the LEDs. For those devices that have more than 32 LEDs, LEDs 33 and above are only covered by the modExpLedStatus object. |
| I32 switchstat | 1.3.6.1.4.1.7342.1.1.1.12 | Integer32 | read-only | The status of any DIP switches on the module. DIP switch 1 is switchstat.0, DIP switch 2 is switchstat.1, DIP switch 3 is switchstat.2, etc. DIP switch bank 1 is switches 0-7 DIP switch bank 2 is switches 8-15 Front panel switches start at switchstat.7 for the top switch, switchstat.6 for the next switch, etc. |
| I32 extended1 | 1.3.6.1.4.1.7342.1.1.1.13 | Integer32 | read-write | General extended status for the module. Normally this is the actual setting of the DIP switch selection. |
| I32 extended2 | 1.3.6.1.4.1.7342.1.1.1.14 | Integer32 | read-write | General extended status for the module |
| I32 extended3 | 1.3.6.1.4.1.7342.1.1.1.15 | Integer32 | read-write | General extended status for the module |
| I32 extended4 | 1.3.6.1.4.1.7342.1.1.1.16 | Integer32 | read-write | General extended status for the module |
| I32 extended5 | 1.3.6.1.4.1.7342.1.1.1.17 | Integer32 | read-write | General extended status for the module |
| I32 extended6 | 1.3.6.1.4.1.7342.1.1.1.18 | Integer32 | read-write | General extended status for the module |
| I32 resetmod | 1.3.6.1.4.1.7342.1.1.1.19 | Integer32 | read-write | Writing to this variable resets the module. This variable is a write only. Writing a zero (0) will reboot to the current working application image Writing a one (1) will reboot to the backup application image if available |
| I32 wrswitch | 1.3.6.1.4.1.7342.1.1.1.20 | Integer32 | read-write | Writing to this variable updates the module switch settings. See switchstat above for the explanation. |
| STR modulename | 1.3.6.1.4.1.7342.1.1.1.21 | DisplayString | read-write | The name of the module |
| I32 chassis | 1.3.6.1.4.1.7342.1.6 | Integer32 | read-only | Holds the chassis number of the selected IP |
| I32 selfSlot | 1.3.6.1.4.1.7342.1.8 | Integer32 | read-only | Holds the slot number of the selected IP |
| prodAgent | 1.3.6.1.4.1.7342.2 | |||
| enhancedchassisTable | 1.3.6.1.4.1.7342.2.1 | |||
| I32 moduleCount | 1.3.6.1.4.1.7342.2.1.1 | Integer32 | read-only | The number of modules in the chassis table |
| moduleTable | 1.3.6.1.4.1.7342.2.1.2 | not-accessible | This a table of modules in the enhances chassis table. It contains as many entries as specified by moduleCount | |
| moduleEntry | 1.3.6.1.4.1.7342.2.1.2.1 | not-accessible | Chassis modules. | |
| I32 modchassnum | 1.3.6.1.4.1.7342.2.1.2.1.1 | Integer32 | read-only | The chassis where the module resides. |
| I32 modslotnum | 1.3.6.1.4.1.7342.2.1.2.1.2 | Integer32 | read-only | The slot number within a chassis. |
| I32 modchasstype | 1.3.6.1.4.1.7342.2.1.2.1.3 | Integer32 | read-only | The type of chassis in which the module resides. |
| I32 modprodtype | 1.3.6.1.4.1.7342.2.1.2.1.4 | Integer32 | read-only | The chassis where the module resides. |
| I32 modsoftrev | 1.3.6.1.4.1.7342.2.1.2.1.5 | Integer32 | read-only | The modules software revision. |
| I32 modprodrev | 1.3.6.1.4.1.7342.2.1.2.1.6 | Integer32 | read-only | The modules product revision. |
| I32 modreset | 1.3.6.1.4.1.7342.2.1.2.1.7 | Integer32 | read-write | Writing to this variable resets the module. This variable is a write only. Writing a zero (0) will reboot to the current working application image Writing a one (1) will reboot to the backup application image if available |
| I32 modnumports | 1.3.6.1.4.1.7342.2.1.2.1.8 | Integer32 | read-only | The number of ports in this module. |
| STR modchassname | 1.3.6.1.4.1.7342.2.1.2.1.9 | DisplayString | read-only | The name of the chassis in which the individual module resides in. For the M2 modules the max size is 32 octets. For the GM3, GM4, XM5 the max size is 64 octets when a module is accessed directly through the serial port, or via its own IP address for Telnet, SSH, or SNMP. For the GM3, GM4, XM5 when the object is indirectly accessed via the backplane, through IP-less, or through 802.3ah peer-to-peer the value is truncated to 32 bytes. |
| STR modpartnum | 1.3.6.1.4.1.7342.2.1.2.1.10 | DisplayString | read-only | The model of the individual module. |
| STR modserialnum | 1.3.6.1.4.1.7342.2.1.2.1.11 | DisplayString | read-only | The serial number of the individual module. |
| STR modmanufdate | 1.3.6.1.4.1.7342.2.1.2.1.12 | DisplayString | read-only | The manufacturing date of the individual module. |
| STR modname | 1.3.6.1.4.1.7342.2.1.2.1.13 | DisplayString | read-only | The name of the individual module. |
| I32 modportvlan | 1.3.6.1.4.1.7342.2.1.2.1.14 | Integer32 | read-write | The portvlan map of an individual module. The low order bits encode the possible values. The following are the connection paths that exists between the ports on the module: Used on types 69, 72, 81, 83, 84, 86 bit0 - Port 1 to Port 2 bit1 - Port 1 to Backplane Port A bit2 - Port 1 to Backplane Port B bit3 - Port 2 to Backplane Port A bit4 - Port 2 to Backplane Port B bit5 - Backplane Port A to Backplane Port B Used on types 70, 80, 90, 93, 94, 95, 96, 98, 100, 101, 105, 106 bit0 - Port 1 to Port 2 bit1 - Port 1 to Backplane Port A bit2 - Port 1 to Backplane Port B bit3 - Port 2 to Backplane Port A bit4 - Port 2 to Backplane Port B bit5 - Backplane Port A to Backplane Port B bit6 - Port 1 to Mgt bit7 - Port 2 to Mgt bit8 - Backplane A to Mgt bit9 - Backplane B to Mgt Used on types 102, 108, 109, 112 bit0 - Port 1-2-3 interconnect bit1 - Port 1-2-3 to Backplane Port A bit2 - Port 1-2-3 to Backplane Port B bit3 - Backplane Port A to Backplane Port B bit4 - Port 1 to Mgt bit5 - Port 2 to Mgt bit6 - Port 3 to Mgt bit7 - Backplane A to Mgt bit8 - Backplane B to Mgt Used on types 97, 99, 113 bit0 - Port 1 to Port 2 bit1 - Port 1 to Backplane Port A bit2 - Port 1 to Backplane Port B bit3 - Port 2 to Backplane Port A bit4 - Port 2 to Backplane Port B bit5 - Backplane Port A to Backplane Port B bit6 - Port 1 to Mgt bit7 - Port 2 to Mgt bit8 - Backplane A to Mgt bit9 - Backplane B to Mgt Used on types 79, 87 bit0 - Port 1-2-3-4 interconnect bit1 - Port 1-2-3-4 to backplane A bit2 - Port 1-2-3-4 to backplane B bite 3 Backplane A to Backplane B Used on type 103 bit0 - Port A to Backplane A bit1 - Port A to Backplane B bit2 - Port B to Backplane A bit3 - Port B to Backplane B bit4 - Port A to Port B |
| I32 modextfeaturebits | 1.3.6.1.4.1.7342.2.1.2.1.15 | Integer32 | read-only | The module's extended features bits. The bit definitions are: bit0 - module is capable of being field upgradeable bit1 - module supports MIB Statistics bit2 - module supports Memory I/O extended registers bit3 - module supports Tag Vlan feature bit4 - module configured as Secure Slave bit5 - module configured as Secure Proxy bit6 - module configured as Secure Master bit7 - module supports 802.3ah OAM Client bit8 - module supports SFP parameters for port1 bit9 - module supports SFP parameters for port2 bit10 - module supports SFP parameters for port3 bit11 - module supports SFP parameters for port4 bit12 - module supports AH event notification bit13 - 1-module redundant power chassis supports contact closure status bit14 - 1-module redundant power chassis supports power over ethernet bit15 - 1-module redundant power chassis RJ45 connector is installed bit16 - 1-module redundant power chassis fan is installed bit17 - when this bit is on the module is a remote slave bit18 - module supports unidirectional on port1 bit19 - module supports unidirectional on port2 bit20 - module supports unidirectional on port3 bit21 - extended power supply bit22 - module supports SNMPv3 bit23 - module is NMM2 capable bit24 - fan is installed bit25 - generic module class supports 802.1ag/Y.1731 bit26 - module GM3 class supports 802.1ag/Y.1731 bit27 - module GM4 class bit28 - port 1 is an XFP port bit29 - port 2 is an XFP port |
| I32 modswbuildnum | 1.3.6.1.4.1.7342.2.1.2.1.16 | Integer32 | read-only | The module's software build number. |
| I32 modenable802dot1qProcessing | 1.3.6.1.4.1.7342.2.1.2.1.17 | Integer32 | read-write | Enables or disables 802_1q processing. 0 = disable 1 = enable |
| I32 modtagsubstitution | 1.3.6.1.4.1.7342.2.1.2.1.18 | Integer32 | read-write | Enables or disables substitution of 802_1q tags. Currently not implemented by any supported module |
| I32 modcommitVLANchanges | 1.3.6.1.4.1.7342.2.1.2.1.19 | Integer32 | read-write | VLAN information is applied to the module and data saved to persistent storage. This variable is a write only. |
| I32 modvlanTableClear | 1.3.6.1.4.1.7342.2.1.2.1.20 | Integer32 | read-write | VLAN table for the module Vlan table to be cleared. This variable is a write only. |
| I32 modcommitNMMCfgChanges | 1.3.6.1.4.1.7342.2.1.2.1.21 | Integer32 | read-write | Management module configuration information is applied to the module and data saved to persistent storage. This variable is a write only. |
| I32 modLM80volts | 1.3.6.1.4.1.7342.2.1.2.1.22 | Integer32 | read-only | 8 bits each of PS1 Voltage(msB), PS2 Voltage, Total Voltage and an unused byte(lsB). 1-module redundant power chassis. |
| I32 modLM80currents | 1.3.6.1.4.1.7342.2.1.2.1.23 | Integer32 | read-only | 8 bits each of PS1 Current(msB) (mA/10), PS2 Current, Total Current and an unused byte(lsB). 1-module redundant power chassis. |
| I32 modLM80misc | 1.3.6.1.4.1.7342.2.1.2.1.24 | Integer32 | read-only | 8 bits each of Temperature(msB) .5C/bit and 2 unused byte(lsB). 1-module redundant power chassis. |
| I32 modRestoreFactoryDefaults | 1.3.6.1.4.1.7342.2.1.2.1.25 | Integer32 | read-write | Management module configuration information is restored to factory defaults. This variable is a write only. Different types of restore defaults are supported: restoreFactoryDefaults(0,1) Restores factory defaults restoreLocalDefaults(2) Restores defaults from local file restorePreviousConfig(3) Restores the previously saved configuration. This is useful to regress to a known working setup. restoreFactoryDefaultsKeepIp(4) Restores factory defaults but keeps IP based settings restoreLocalDefaultsKeepIp(5) Restores defaults from local file but keeps IP based settings. restorePreviousConfigKeepIp(6) Restores the previously saved configuration but keeps IP based settings. |
| I32 coreStatusOnly | 1.3.6.1.4.1.7342.2.1.2.1.26 | Integer32 | read-write | Enable(1) or disable(0) Core Status Only. |
| I32 ingressPolicingType | 1.3.6.1.4.1.7342.2.1.2.1.27 | Integer32 | read-write | Sets the module global policy used to count bytes for bandwidth calculation purposes. This is available on the GM3 & GM4. This is not available on the XM5. 1 = L1 includes all bytes in frame, interframe gap and preamble 2 = L2 includes all bytes in frame, including Layer 2 header and CRC 3 = L3 includes Layer 3 information only, excludes Layer 2 header and CRC |
| I32 vlanservicetag | 1.3.6.1.4.1.7342.2.1.2.1.28 | Integer32 | read-write | Value for service tag. |
| I32 defaultForwardingMap | 1.3.6.1.4.1.7342.2.1.2.1.29 | Integer32 | read-write | Bit vector for default forwarding map where: bit0 - Port 1 bit1 - Port 2 bit2 - Port 3 bit3 - Port 4 bit4 - Port BPA bit5 - Port BPB |
| STR modFpgaRev | 1.3.6.1.4.1.7342.2.1.2.1.30 | DisplayString | read-only | The current revision of the FPGA. |
| STR modExpPartNumber | 1.3.6.1.4.1.7342.2.1.2.1.31 | DisplayString | read-only | The expanded part number of the individual module. The modpartnum object indicates the compressed version of the part number name. If this field is not supported in a module it is left as a null length string. |
| STR modExpSoftwareRev | 1.3.6.1.4.1.7342.2.1.2.1.32 | DisplayString | read-only | The expanded software revision of the individual module. This object allows for an enhanced version of the software revision that include a major and minor component. Major and Minor are always numeric values while the rev value can be a number or an alpha. For instance: 1.0, 1.1, 3.2A, 1.1.2. The two digit modsoftrev object includes the major and minor revision. A modsoftrev of '32' would be shown in this object as '3.2'. This object allows the minor number to be expanded beyond a single digit as shown above by '3.2A' above, even though modsoftrev would be '32'. The modswbuildnum is independent of this scheme, but the complete revision is sometimes referred together as a concatenated value. For instance is '3.2A' is the sofware rev and '1234' is the build number, the concatenated value is '3.2A.1234'. |
| OCT modExpLedStatus | 1.3.6.1.4.1.7342.2.1.2.1.33 | OCTET STRING | read-only | This object is the expanded LED status of the individual module. This object reflects the state, color, and blinking rate of each individual LED. Each LED is represented by a single octet. The first octet in the string is the first LED, the second octet in the string is the second LED, until the last LED. The length of the object indicates the number of LEDs of the modules. Non-installed (missing) LEDs return a value of all zeros. Each octet is encoded in the following way: Bits 0:1 indicate the LED color and state 0x0 = LED is off 0x1 = LED is amber 0x2 = LED is green 0x3 = LED is both amber and green (red) Bits 2:4 indicate the LED blinking frequency 0x0 = LED is solid 0x1 = LED is blinking at 10 Hz 0x2 = LED is blinking at 5 Hz 0x3 = LED is blinking at 2 Hz 0x4 = LED is blinking at 1 Hz 0x5 = LED is blinking at 1/2 Hz Bits 5:7 are currently undefined and return 0x0 for this product revision. |
| STR modHwRev | 1.3.6.1.4.1.7342.2.1.2.1.34 | DisplayString | read-only | The current hardware revision of the module. |
| STR modPcbRev | 1.3.6.1.4.1.7342.2.1.2.1.35 | DisplayString | read-only | The current PCB revision of the module. |
| moduleMgtCfgTable | 1.3.6.1.4.1.7342.2.1.3 | not-accessible | This is a table of the management module configuration variables. | |
| moduleMgtCfgEntry | 1.3.6.1.4.1.7342.2.1.3.1 | not-accessible | Chassis modules. | |
| I32 sysAdminStatus | 1.3.6.1.4.1.7342.2.1.3.1.1 | Integer32 | read-only | This variable provides the status for a management module's ability to make changes to the system. In backplane slave, a management module cannot make system modification. Modifications must be performed from a management module acting as a backplane master. 0 = read only (can only view configuration settings) 1 = read-write (can view and modify configuration settings). |
| STR sysDateTime | 1.3.6.1.4.1.7342.2.1.3.1.2 | DisplayString | read-write | This variable provides the date and time in display format: nn/dd/yyyy hh:mm:ss where nn = 2 digit month, dd = 2 digit day, yyyy = 4 digit year hh - 2 digit hour 0-23, mm = 2 digit minutes 0-59, ss = 2 digit secs 0-59 |
| STR macAddr | 1.3.6.1.4.1.7342.2.1.3.1.3 | DisplayString | read-only | MAC address of the management module |
| IP ipAddr | 1.3.6.1.4.1.7342.2.1.3.1.4 | IpAddress | read-write | IP of the management module |
| IP subnetmask | 1.3.6.1.4.1.7342.2.1.3.1.5 | IpAddress | read-write | subnetmask for the management module |
| IP gateway | 1.3.6.1.4.1.7342.2.1.3.1.6 | IpAddress | read-write | IP address for the gateway the management module will use. |
| STR readCommunity | 1.3.6.1.4.1.7342.2.1.3.1.7 | DisplayString | read-write | SNMP read community name. |
| STR writeCommunity | 1.3.6.1.4.1.7342.2.1.3.1.8 | DisplayString | read-write | SNMP set community name. |
| I32 mychassnum | 1.3.6.1.4.1.7342.2.1.3.1.9 | Integer32 | read-write | NMMs chassis number. |
| STR mmname | 1.3.6.1.4.1.7342.2.1.3.1.10 | DisplayString | read-write | Management Modules chassis name. For the M2 modules the max size is 32 octets. For the GM3, GM4, XM5 the max size is 64 octets when a module is accessed directly through the serial port, or via its own IP address for Telnet, SSH, or SNMP. For the GM3, GM4, XM5 when the object is indirectly accessed via the backplane, through IP-less, or through 802.3ah peer-to-peer the value is truncated to 32 bytes. |
| IP traphost1 | 1.3.6.1.4.1.7342.2.1.3.1.11 | IpAddress | read-write | NMMs traphost1 IP address. |
| IP traphost2 | 1.3.6.1.4.1.7342.2.1.3.1.12 | IpAddress | read-write | NMMs traphost2 IP address. |
| IP traphost3 | 1.3.6.1.4.1.7342.2.1.3.1.13 | IpAddress | read-write | NMMs traphost3 IP address. |
| IP traphost4 | 1.3.6.1.4.1.7342.2.1.3.1.14 | IpAddress | read-write | NMMs traphost4 IP address. |
| IP traphost5 | 1.3.6.1.4.1.7342.2.1.3.1.15 | IpAddress | read-write | NMMs traphost5 IP address. |
| IP traphost6 | 1.3.6.1.4.1.7342.2.1.3.1.16 | IpAddress | read-write | NMMs traphost6 IP address. |
| IP traphost7 | 1.3.6.1.4.1.7342.2.1.3.1.17 | IpAddress | read-write | NMMs traphost7 IP address. |
| IP traphost8 | 1.3.6.1.4.1.7342.2.1.3.1.18 | IpAddress | read-write | NMMs traphost8 IP address. |
| STR sysloc | 1.3.6.1.4.1.7342.2.1.3.1.19 | DisplayString | read-write | Management Modules system location. For the M2 modules the max size is 32 octets. For the GM3, GM4, XM5 the max size is 64 octets when a module is accessed directly through the serial port, or via its own IP address for Telnet, SSH, or SNMP. For the GM3, GM4, XM5 when the object is indirectly accessed via the backplane, through IP-less, or through 802.3ah peer-to-peer the value is truncated to 32 bytes. |
| STR syscon | 1.3.6.1.4.1.7342.2.1.3.1.20 | DisplayString | read-write | Management Modules system Contact information. For the M2 modules the max size is 32 octets. For the GM3, GM4, XM5 the max size is 64 octets when a module is accessed directly through the serial port, or via its own IP address for Telnet, SSH, or SNMP. For the GM3, GM4, XM5 when the object is indirectly accessed via the backplane, through IP-less, or through 802.3ah peer-to-peer the value is truncated to 32 bytes. |
| STR serialpass | 1.3.6.1.4.1.7342.2.1.3.1.21 | DisplayString | read-write | NMMs serial interface password. |
| STR telnetpass | 1.3.6.1.4.1.7342.2.1.3.1.22 | DisplayString | read-write | NMMs telnet interface password. |
| STR ftppasswrd | 1.3.6.1.4.1.7342.2.1.3.1.23 | DisplayString | read-write | NMMs ftp password. |
| I32 keepAliveInterval | 1.3.6.1.4.1.7342.2.1.3.1.24 | Integer32 | read-write | This the interval used by the NMM to send out keep alive traps. |
| OST vlanIdOst | 1.3.6.1.4.1.7342.2.1.3.1.25 | OstVlanId | read-write | Management module VLAN tagged packet ID. |
| I32 nmmCfgSerialBaudrate | 1.3.6.1.4.1.7342.2.1.3.1.26 | Integer32 | read-write | This variable defines the baud rate for the serial interface to the NMM. Where: 1 = 300 bps 2 = 1200 bps 3 = 2400 bps 4 = 4800 bps 5 = 9600 bps 6 = 19200 bps 7 = 38400 bps 8 = 57600 bps 9 = 115200 bps |
| I32 enabledFunctions | 1.3.6.1.4.1.7342.2.1.3.1.27 | Integer32 | read-write | This variable defines which special functions are enabled at the NMM. Where: 0x01 = Keep Alive trap enabled 0x02 = Telnet enabled 0x04 = FTP enabled 0x08 = switch reload enabled 0x10 = VLAN enabled 0x20 = sw1 block enabled 0x40 = DHCP client enabled 0x80 = Trap 99 processing enabled |
| I32 enableSNMPFunction | 1.3.6.1.4.1.7342.2.1.3.1.28 | Integer32 | read-write | This variable defines whether the SNMP Agent is enabled at the NMM. Where: 00 = SNMP disabled 01 = SNMP enabled |
| I32 nmmCfgState | 1.3.6.1.4.1.7342.2.1.3.1.29 | Integer32 | read-only | This variable defines the state of the configuration changes made to the NMM. Where: 0x00 = No changes 0x02 = Changes Pending (not saved in Flash) 0x04 = Saved in Flash, Pending NMM reboot |
| I32 nmmSecureMode | 1.3.6.1.4.1.7342.2.1.3.1.30 | Integer32 | read-write | This variable defines the mode the Management module will operate in when configured for SECURE COMMUNICATIONS. Where: 0x00 = No Secure Communications 0x01 = Secure Proxy 0x02 = Secure Slave 0x03 = Secure Master |
| I32 nmmSecureConnState | 1.3.6.1.4.1.7342.2.1.3.1.31 | Integer32 | read-only | This variable returns the secure connection state between the proxy and secure slave. Where: 0x00 = Not connected 0x01 = Connection Pending 0x02 = Connection established 0x03 = Connection terminating |
| I32 nmmIpProtocolState | 1.3.6.1.4.1.7342.2.1.3.1.32 | Integer32 | read-only | This variable defines whether the IP protocol is active or disabled. 0 = Active 1 = Disabled |
| I32 nmmIpDisabled | 1.3.6.1.4.1.7342.2.1.3.1.33 | Integer32 | read-write | This variable defines the configuration value for IP protocol's desired state. 0 = ipActive 1 = ipDisabled |
| I32 vlanPri | 1.3.6.1.4.1.7342.2.1.3.1.34 | Integer32 | read-write | Management module VLAN tagged packet priority. |
| I32 enableSNMPWrites | 1.3.6.1.4.1.7342.2.1.3.1.35 | Integer32 | read-write | Permit SNMP SET operations. |
| I32 cpuVoltageIn | 1.3.6.1.4.1.7342.2.1.3.1.36 | Integer32 | read-only | voltage input to cpu. |
| I32 cpuVoltageOut | 1.3.6.1.4.1.7342.2.1.3.1.37 | Integer32 | read-only | Voltage out from the cpu. |
| I32 cpuTemperature | 1.3.6.1.4.1.7342.2.1.3.1.38 | Integer32 | read-only | The ambient temperature of the CPU. |
| I32 nmmSecureSlaveSlot | 1.3.6.1.4.1.7342.2.1.3.1.39 | Integer32 | read-only | The slot number of the secure slave in the remote chassis when configured for SECURE COMMUNICATIONS. |
| IP dhcpIpAddr | 1.3.6.1.4.1.7342.2.1.3.1.40 | IpAddress | read-only | IP of the management module as assigned by a DHCP server |
| IP dhcpSubnetmask | 1.3.6.1.4.1.7342.2.1.3.1.41 | IpAddress | read-only | subnetmask of the management module as assigned by a DHCP server |
| IP dhcpGateway | 1.3.6.1.4.1.7342.2.1.3.1.42 | IpAddress | read-only | Gateway IP address of the management module as assigned by a DHCP Server |
| I32 nmmOAMmgmtMode | 1.3.6.1.4.1.7342.2.1.3.1.43 | Integer32 | read-write | This variable configures the protocol the Management module will use to communicate with remote chassis when operating in secure mode. Where: 0x01 = (OAM_OFF) No Secure Communications protocol 0x02 = (Auto SECURE_OAM) Use OST proprietary protocol, force remote to switch if not in the OAM_OFF mode 0x03 = (Auto AH_OAM) Use AH protocol, force remote to switch if not in the OAM_OFF mode 0x04 = (SECURE_OAM) Use OST proprietary protocol, remote is not forced to switch and must match modes to connect 0x05 = (AH_OAM) Use AH protocol, remote is not forced to switch and must match modes to connect |
| I32 customertag | 1.3.6.1.4.1.7342.2.1.3.1.44 | Integer32 | read-write | Value for customer tag. |
| I32 servicetag | 1.3.6.1.4.1.7342.2.1.3.1.45 | Integer32 | read-write | Value for service tag. |
| I32 cnodeControl | 1.3.6.1.4.1.7342.2.1.3.1.46 | Integer32 | read-write | Controls whether the module is operating as a Cnode. |
| I32 cnodeCIR | 1.3.6.1.4.1.7342.2.1.3.1.47 | Integer32 | read-write | Cnode CIR Where: 1 = 64 Kbps 2 = 128 Kbps 3 = 192 Kbps |
| I32 enableSNMPv3Function | 1.3.6.1.4.1.7342.2.1.3.1.48 | Integer32 | read-write | This variable defines whether the SNMPv3 Agent is enabled at the NMM. Where: 00 = SNMP disabled 01 = SNMP enabled |
| I32 slaveWrite | 1.3.6.1.4.1.7342.2.1.3.1.49 | Integer32 | read-write | This variable defines whether the module should be allowed to make configurations to itself when in the chassis slave mode. Where: 00 = slaveWrite disabled 01 = slaveWrite enabled |
| I32 snmpTrapType | 1.3.6.1.4.1.7342.2.1.3.1.50 | Integer32 | read-write | This variable defines which version of SNMP traps are supported, where: 1 = SNMPv1 traps 2 = SNMPv2c traps 3 = SNMPv3 traps |
| U32 capsMask | 1.3.6.1.4.1.7342.2.1.3.1.51 | Unsigned32 | read-only | Capablility bits for this management module. |
| I32 slaveTraps | 1.3.6.1.4.1.7342.2.1.3.1.52 | Integer32 | read-write | This variable defines whether the module should be allowed to transmit traps out ethernet ports eventhough it is not a chassis master. Where: 00 = slaveTraps disabled 01 = slaveTraps enabled |
| I32 slaveTrapsForward | 1.3.6.1.4.1.7342.2.1.3.1.53 | Integer32 | read-write | This variable defines whether the module should be allowed to forward traps to the chassis master when module is a chassis slave. Default is forward. Where: 00 = slaveTrapsForward disabled 01 = slaveTrapsForward enabled |
| IP ipAddr2 | 1.3.6.1.4.1.7342.2.1.3.1.54 | IpAddress | read-write | IP 2 of the management module |
| IP subnetmask2 | 1.3.6.1.4.1.7342.2.1.3.1.55 | IpAddress | read-write | subnetmask 2 for the management module |
| IP gateway2 | 1.3.6.1.4.1.7342.2.1.3.1.56 | IpAddress | read-write | IP address for the gateway 2 the management module will use. |
| STR ipaddrEVCassociation | 1.3.6.1.4.1.7342.2.1.3.1.57 | DisplayString | read-write | *** This object is deprecated *** EVC associated with ipaddr 1. |
| STR ipaddr2EVCassociation | 1.3.6.1.4.1.7342.2.1.3.1.58 | DisplayString | read-write | *** This object is deprecated *** EVC associated with ipaddr 2. |
| T/F bootpEnable | 1.3.6.1.4.1.7342.2.1.3.1.59 | TruthValue | read-write | Enable or disable BOOTP. |
| T/F tftpEnable | 1.3.6.1.4.1.7342.2.1.3.1.60 | TruthValue | read-write | Enable or disable TFTP. |
| IP tftpServerIpAddress | 1.3.6.1.4.1.7342.2.1.3.1.61 | IpAddress | read-write | TFTP server IP address. |
| IP dhcptftpServerIpAddress | 1.3.6.1.4.1.7342.2.1.3.1.62 | IpAddress | read-only | TFTP Server IP address as assigned by a DHCP Server |
| STR tftpFileName | 1.3.6.1.4.1.7342.2.1.3.1.63 | DisplayString | read-write | Selects the TFTP file name. |
| OST modeType | 1.3.6.1.4.1.7342.2.1.3.1.64 | OstModeType | read-write | Sets the module Mode Type to normal, AP, or SP. |
| I32 dhcpPortNumber | 1.3.6.1.4.1.7342.2.1.3.1.65 | Integer32 | read-write | Sets the DHCP port number. 2 port module: 1=None, 2=Port 1, 3=Port 2, 4=BP A, 5=BP B 3 port module: 1=None, 2=Port 1, 3=Port 2, 4=Port 3, 5=BP A, 6=BP B 5 ports and higher modules: 1=None, 2..n+1 = Port 1..n |
| OST dhcpTagVid | 1.3.6.1.4.1.7342.2.1.3.1.66 | OstVlanId | read-write | Sets the DHCP Tag VLAN ID. |
| U32 trapSrcIpSelect | 1.3.6.1.4.1.7342.2.1.3.1.67 | Unsigned32 | read-write | Selects the trap source address, IP1(1) or IP2(2). |
| T/F muxGroupDefaults | 1.3.6.1.4.1.7342.2.1.3.1.68 | TruthValue | read-write | This object when written sets the Mux Grouping defaults for a management module. When read the value always returns 'false'. Writing this sets the Mux Group EVC and bandwidth profile configurations. |
| INT portFwdCpu | 1.3.6.1.4.1.7342.2.1.3.1.69 | INTEGER | read-write | This object enables forwarding of managment traffic from the selected ports only for M2 modules only. Management traffic from ports not defined is dropped. all(0) Management traffic forwarded from all ports port1(1) Management traffic forwarded from Port 1 only port2(2) Management traffic forwarded from Port 2 only backplaneA(3) Management traffic forwarded from BP A only backplaneB(4) Management traffic forwarded from BP B only |
| OST portFwdCpuList | 1.3.6.1.4.1.7342.2.1.3.1.70 | OstPortList | read-write | This object enables forwarding of managment traffic from the selected ports only for M3, M4, and M5 modules only. Management traffic from ports not defined is dropped. |
| modulePortsTable | 1.3.6.1.4.1.7342.2.1.4 | not-accessible | This a table of Ports per module. There are as many entries as specified by modnumports in the moduleEntry | |
| modulePortsEntry | 1.3.6.1.4.1.7342.2.1.4.1 | not-accessible | Ports per module table. | |
| OST portnum | 1.3.6.1.4.1.7342.2.1.4.1.1 | OstPortNumber | not-accessible | Used to get or set state of port. |
| INT portState | 1.3.6.1.4.1.7342.2.1.4.1.2 | INTEGER | read-write | Used to get or set state of port. |
| I32 portEgressRate | 1.3.6.1.4.1.7342.2.1.4.1.3 | Integer32 | read-write | Used to get or set the port throughput limit selection. The following are the limits are enforced by module type: Used on types 80, 96, 70, 90, 86, 84, 87 (lower limit=0, upper limit=7) where: 0 = 100 Mbps 1 = 128 kbps 2 = 256 kbps 3 = 512 kbps 4 = 1 Mbps 5 = 2 Mbps 6 = 4 Mbps 7 = 8 Mbps Used on types 100, 101 (lower limit=1, upper limit=20) where: 1 = 64 kbps 2 = 128 kbps 3 = 256 kbps 4 = 512 kbps 5 = 768 kbps 6 = 1 Mbps 7 = 2 Mbps 8 = 3 Mbps 9 = 4 Mbps 10 = 5 Mbps 11 = 6 Mbps 12 = 7 Mbps 13 = 8 Mbps 14 = 9 Mbps 15 = 10 Mbps 16 = 20 Mbps 17 = 30 Mbps 18 = 40 Mbps 19 = 50 Mbps 20 = 100 Mbps Used on types 105, 106 (lower limit=1, upper limit=33) 1 = 64 kbps 2 = 128 kbps 3 = 256 kbps 4 = 512 kbps 5 = 768 kbps 6 = 1 Mbps 7 = 2 Mbps 8 = 3 Mbps 9 = 4 Mbps 10 = 5 Mbps 11 = 6 Mbps 12 = 7 Mbps 13 = 8 Mbps 14 = 9 Mbps 15 = 10 Mbps 16 = 20 Mbps 17 = 30 Mbps 18 = 40 Mbps 19 = 50 Mbps 20 = 60 Mbps 21 = 70 Mbps 22 = 80 Mbps 23 = 90 Mbps 24 = 100 Mbps 25 = 200 Mbps 26 = 300 Mbps 27 = 400 Mbps 28 = 500 Mbps 29 = 600 Mbps 30 = 700 Mbps 31 = 800 Mbps 32 = 900 Mbps 33 = 1000 Mbps Types 97, 99, 102, 108, 109, 112, 113 use numeric values in kpbs with a lower limit of 64 and an upper limit of 1,000,000. Types not listed have no limit. |
| I32 portpriority | 1.3.6.1.4.1.7342.2.1.4.1.4 | Integer32 | read-write | Used to get or set port user-priority. |
| I32 portcanonicalformatIndicator | 1.3.6.1.4.1.7342.2.1.4.1.5 | Integer32 | read-write | Used to get or set port cfi. Currently not used and defaulted to 0 |
| I32 portvlanidentifier | 1.3.6.1.4.1.7342.2.1.4.1.6 | Integer32 | read-write | Used to get or set port VID. |
| I32 portmlistcriteria | 1.3.6.1.4.1.7342.2.1.4.1.7 | Integer32 | read-write | Used to get or set port membership criteria. |
| I32 portingresssecurity | 1.3.6.1.4.1.7342.2.1.4.1.8 | Integer32 | read-write | Used to get or set port ingress security. |
| I32 portegresspolicy | 1.3.6.1.4.1.7342.2.1.4.1.9 | Integer32 | read-write | Used to get or set port egress policy. |
| I32 portIngressRate | 1.3.6.1.4.1.7342.2.1.4.1.10 | Integer32 | read-write | Used to get or set the port throughput limit selection. The following are the limits are enforced by module type: Used on types 80, 96, 70, 90, 86, 84, 87 (lower limit=0, upper limit=7) where: 0 = 100 Mbps 1 = 128 kbps 2 = 256 kbps 3 = 512 kbps 4 = 1 Mbps 5 = 2 Mbps 6 = 4 Mbps 7 = 8 Mbps Used on types 100, 101 (lower limit=64, upper limit=100,000) Values are number of kbps per second, i.e. rate = value x 1000, units in bps Used on types 97, 99, 102, 105, 106, 108, 109, 112, 113 (lower limit=64, upper limit=1,000,000) Values are number of kbps per second, i.e. rate = value x 1000, units in bps Types not listed have no limit. |
| I32 portSpeed | 1.3.6.1.4.1.7342.2.1.4.1.11 | Integer32 | read-only | Used to get the port speed. 0 = undefined 1 = speed10Mbps 2 = speed100Mbps 3 = speed1Gbps 4 = speed10Gbps |
| I32 portUnidirectionalAhOamEnable | 1.3.6.1.4.1.7342.2.1.4.1.12 | Integer32 | read-write | Used to get/set the unidirectional support. 0 = uniDisabled 1 = uniEnabled |
| I32 portIngressRateDropOrPause | 1.3.6.1.4.1.7342.2.1.4.1.13 | Integer32 | read-write | Used to get/set behavior on overflow. 0 = undefined 1 = inDrop 2 = inPause |
| I32 portIngressRateCBS | 1.3.6.1.4.1.7342.2.1.4.1.14 | Integer32 | read-write | Used to get or set the port throughput limit selection. |
| I32 portL2CPmgntProcessing | 1.3.6.1.4.1.7342.2.1.4.1.15 | Integer32 | read-write | Used to get or set the port L2Cp processing method. 0 = undefined 1 = inDrop 2 = inForward 3 = inTunnel |
| I32 portEgressQosPolicy | 1.3.6.1.4.1.7342.2.1.4.1.16 | Integer32 | read-write | Used to get or set the port egress QoS Policy. 0 = undefined 1 = fairWeight 2 = starving |
| I32 portAccessType | 1.3.6.1.4.1.7342.2.1.4.1.17 | Integer32 | read-write | Used to get or set the port access type. 0 = undefined 1 = tunnel 2 = access 3 = trunk |
| I32 portStatsClear | 1.3.6.1.4.1.7342.2.1.4.1.18 | Integer32 | read-write | Used to clear the statistics table for this port |
| I32 portLinkState | 1.3.6.1.4.1.7342.2.1.4.1.19 | Integer32 | read-only | Reports the link state of the port. 0 = No link 1 = Linked |
| INT portDuplex | 1.3.6.1.4.1.7342.2.1.4.1.20 | INTEGER | read-only | The object indcates the linked port duplex mode. undefined(0) Port is not linked or state of duplex is unknown halfDuplex(1) Port is linked at half duplex fullDuplex(2) Port is linked at full duplex |
| STR portMacAddress | 1.3.6.1.4.1.7342.2.1.4.1.21 | DisplayString | read-only | MAC address of the port. If a MAC address doesn't exist on a port the value returned is all zeros. |
| portStatsTable | 1.3.6.1.4.1.7342.2.1.5 | not-accessible | This a table of Statistics per port. | |
| portStatsEntry | 1.3.6.1.4.1.7342.2.1.5.1 | not-accessible | extended module statitical information. | |
| C32 txOctetsEx | 1.3.6.1.4.1.7342.2.1.5.1.1 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 txDropPkts | 1.3.6.1.4.1.7342.2.1.5.1.2 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 txBroadcastPkts | 1.3.6.1.4.1.7342.2.1.5.1.3 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 txMulticastPkts | 1.3.6.1.4.1.7342.2.1.5.1.4 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 txUnicastPkts | 1.3.6.1.4.1.7342.2.1.5.1.5 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 txGoodPkts | 1.3.6.1.4.1.7342.2.1.5.1.6 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 txErrorPkts | 1.3.6.1.4.1.7342.2.1.5.1.7 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 txPausePkts | 1.3.6.1.4.1.7342.2.1.5.1.8 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 txCollisions | 1.3.6.1.4.1.7342.2.1.5.1.9 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 txSingleCollision | 1.3.6.1.4.1.7342.2.1.5.1.10 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 txMultipleCollision | 1.3.6.1.4.1.7342.2.1.5.1.11 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 txDeferedTransmit | 1.3.6.1.4.1.7342.2.1.5.1.12 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 txLateCollision | 1.3.6.1.4.1.7342.2.1.5.1.13 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 txExcessiveCollision | 1.3.6.1.4.1.7342.2.1.5.1.14 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 txDroppedEvents | 1.3.6.1.4.1.7342.2.1.5.1.15 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 rxOctets | 1.3.6.1.4.1.7342.2.1.5.1.16 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 rxDropPkts | 1.3.6.1.4.1.7342.2.1.5.1.17 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 rxBroadcastPkts | 1.3.6.1.4.1.7342.2.1.5.1.18 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 rxMulticastPkts | 1.3.6.1.4.1.7342.2.1.5.1.19 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 rxUnicastPkts | 1.3.6.1.4.1.7342.2.1.5.1.20 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 rxGoodPkts | 1.3.6.1.4.1.7342.2.1.5.1.21 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 rxTotalPkts | 1.3.6.1.4.1.7342.2.1.5.1.22 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 rxErrorPkts | 1.3.6.1.4.1.7342.2.1.5.1.23 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 rxPausePkts | 1.3.6.1.4.1.7342.2.1.5.1.24 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 rxUndersizePkts | 1.3.6.1.4.1.7342.2.1.5.1.25 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 rxOversizePkts | 1.3.6.1.4.1.7342.2.1.5.1.26 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 rxFragments | 1.3.6.1.4.1.7342.2.1.5.1.27 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 rxJabbers | 1.3.6.1.4.1.7342.2.1.5.1.28 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 rxAlignmentErrors | 1.3.6.1.4.1.7342.2.1.5.1.29 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 rxFCSErrors | 1.3.6.1.4.1.7342.2.1.5.1.30 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 rxSymbolErrors | 1.3.6.1.4.1.7342.2.1.5.1.31 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 rxCRCAlignErrors | 1.3.6.1.4.1.7342.2.1.5.1.32 | Counter32 | read-only | Statistics counter - Object name explains its usage. |
| C32 rxPackets64 | 1.3.6.1.4.1.7342.2.1.5.1.33 | Counter32 | read-only | Statistics counter - packets of octet count in object name. |
| C32 rxPackets65to127 | 1.3.6.1.4.1.7342.2.1.5.1.34 | Counter32 | read-only | Statistics counter - packets of octet count in object name. |
| C32 rxPackets128to255 | 1.3.6.1.4.1.7342.2.1.5.1.35 | Counter32 | read-only | Statistics counter - packets of octet count in object name. |
| C32 rxPackets256to511 | 1.3.6.1.4.1.7342.2.1.5.1.36 | Counter32 | read-only | Statistics counter - packets of octet count in object name. |
| C32 rxPackets512to1023 | 1.3.6.1.4.1.7342.2.1.5.1.37 | Counter32 | read-only | Statistics counter - packets of octet count in object name. |
| C32 rxPackets1024to1518 | 1.3.6.1.4.1.7342.2.1.5.1.38 | Counter32 | read-only | Statistics counter - packets of octet count in object name. |
| C64 txOctets64 | 1.3.6.1.4.1.7342.2.1.5.1.39 | Counter64 | read-only | 64 bit octet transmission counter. |
| C64 rxOctets64 | 1.3.6.1.4.1.7342.2.1.5.1.40 | Counter64 | read-only | 64 bit octet receive counter. |
| moduleVLANTable | 1.3.6.1.4.1.7342.2.1.6 | not-accessible | This a table of VLAN entries per module. There is a maximum of 64 valid entries in the table | |
| moduleVLANEntry | 1.3.6.1.4.1.7342.2.1.6.1 | not-accessible | VLAN module table. | |
| I32 index | 1.3.6.1.4.1.7342.2.1.6.1.1 | Integer32 | not-accessible | Used to get or set elements in the vlan table entry. |
| I32 validityflag | 1.3.6.1.4.1.7342.2.1.6.1.2 | Integer32 | read-write | Used to set or delete a VLAN table entry. 0 = entry does not exists or is to be deleted, 1 = entry to be created or re-activated (in the case the entry was modified, the module needs to be notified of the change. This would constitute a re-activation. |
| I32 vlanidentifier | 1.3.6.1.4.1.7342.2.1.6.1.3 | Integer32 | read-write | Used to set or get the vlan identifier. valid settable range is 0-4095 |
| I32 port1Membership | 1.3.6.1.4.1.7342.2.1.6.1.4 | Integer32 | read-write | Used to set or get the port's membership in the specified vlan. 0 = not a member 1 = include in membership |
| I32 port2Membership | 1.3.6.1.4.1.7342.2.1.6.1.5 | Integer32 | read-write | Used to set or get the port's membership in the specified vlan. 0 = not a member 1 = include in membership |
| I32 port3Membership | 1.3.6.1.4.1.7342.2.1.6.1.6 | Integer32 | read-write | Used to set or get the port's membership in the specified vlan. 0 = not a member 1 = include in membership |
| I32 port4Membership | 1.3.6.1.4.1.7342.2.1.6.1.7 | Integer32 | read-write | Used to set or get the port's membership in the specified vlan. 0 = not a member 1 = include in membership |
| I32 port5Membership | 1.3.6.1.4.1.7342.2.1.6.1.8 | Integer32 | read-write | Used to set or get the port's membership in the specified vlan. 0 = not a member 1 = include in membership |
| I32 port6Membership | 1.3.6.1.4.1.7342.2.1.6.1.9 | Integer32 | read-write | Used to set or get the port's membership in the specified vlan. 0 = not a member 1 = include in membership |
| portAHTable | 1.3.6.1.4.1.7342.2.1.7 | not-accessible | This is a table of AH parameter entries per port. | |
| portAHEntry | 1.3.6.1.4.1.7342.2.1.7.1 | not-accessible | AH port table. | |
| I32 ahEnabled | 1.3.6.1.4.1.7342.2.1.7.1.1 | Integer32 | read-write | Used to get or set the state of the AH protocol over specified port. 0 = disable - this port is not actively using the AH protocol 1 = enabled - this port is actively using the AH protocol |
| I32 ahLpbkMode | 1.3.6.1.4.1.7342.2.1.7.1.2 | Integer32 | read-write | Used to get or set the state of the OAM remote loopback. 0 = off - remote loopback is not active 1 = on - remote loopback has been activated |
| I32 ahLocalMode | 1.3.6.1.4.1.7342.2.1.7.1.3 | Integer32 | read-write | Used to get or set the mode AH OAM Client. 0 = PASSIVE - Does not initiate discovery or remote loopbacks 1 = ACTIVE - Initiates discovery process and may initiate remote loopbacks 2 = PASSIVE, PROTECTED - Same as PASSIVE but disallows configuration requests from link partner using AH extensions 3 = ACTIVE, PROTECTED - Same as ACTIVE but disallows configuration requests from link partner using AH extensions |
| I32 ahRemoteMode | 1.3.6.1.4.1.7342.2.1.7.1.4 | Integer32 | read-only | Used to get or set the mode AH OAM Client. 0 = PASSIVE - Does not initiate discovery or remote loopbacks 1 = ACTIVE - Initiates discovery process and may initiate remote loopbacks 2 = PASSIVE, PROTECTED - Same as PASSIVE but disallows configuration requests from link partner using AH extensions 3 = ACTIVE, PROTECTED - Same as ACTIVE but disallows configuration requests from link partner using AH extensions |
| I32 ahLocalMuxState | 1.3.6.1.4.1.7342.2.1.7.1.5 | Integer32 | read-only | Used to get local multiplexer state. 0 = FWD - Multiplexer passes MAC client frames to subordinate sublayer 1 = DISCARD - Multiplexer discards MAC client frames |
| I32 ahRemoteMuxState | 1.3.6.1.4.1.7342.2.1.7.1.6 | Integer32 | read-only | Used to get remote multiplexer state. 0 = FWD - Multiplexer passes MAC client frames to subordinate sublayer 1 = DISCARD - Multiplexer discards MAC client frames |
| I32 ahLocalParserState | 1.3.6.1.4.1.7342.2.1.7.1.7 | Integer32 | read-only | Used to get local parser state. 0 = FWD - Parser passes received non-OAMPDUs to subordinate sublayer 1 = LOOPBACK - Parser passes received non-OAMPDUs to Multiplexer during remote loopback test 2 = DISCARD - Parser discards received non-OAMPDUs |
| I32 ahRemoteParserState | 1.3.6.1.4.1.7342.2.1.7.1.8 | Integer32 | read-only | Used to get remote parser state. 0 = FWD - Parser passes received non-OAMPDUs to subordinate sublayer 1 = LOOPBACK - Parser passes received non-OAMPDUs to Multiplexer during remote loopback test 2 = DISCARD - Parser discards received non-OAMPDUs |
| I32 ahLocalSupportVar | 1.3.6.1.4.1.7342.2.1.7.1.9 | Integer32 | read-only | Used to get local configured features supported in bit encoded value. where: bit0 = OAM Mode bit1 = Unidirectional support bit2 = Loopback Support bit3 = interprets link events bit4 = Variable Retrieval bit5 = Critical Event |
| I32 ahLocalLinkFlags | 1.3.6.1.4.1.7342.2.1.7.1.10 | Integer32 | read-only | Used to get Link Event status in bit encoded value. where: bit0 = Link Fault bit1 = Dying Gasp bit2 = Critical Event bit3 = Local Evaluating bit4 = Local Stable bit5 = Remote Evaluating bit6 = Remote Stable |
| I32 ahLocalLpbkTimeout | 1.3.6.1.4.1.7342.2.1.7.1.11 | Integer32 | read-write | Used to get/set Remote Loopback timeout. Value is in seconds with range 0 - 300. |
| I32 ahRemoteSupportVar | 1.3.6.1.4.1.7342.2.1.7.1.12 | Integer32 | read-only | Used to get remote configured features supported in bit encoded value. where: bit0 = OAM Mode bit1 = Unidirectional support bit2 = Loopback Support bit3 = interprets link events bit4 = Variable Retrieval bit5 = Critical Event |
| I32 ahRemoteLinkFlags | 1.3.6.1.4.1.7342.2.1.7.1.13 | Integer32 | read-only | Used to get Link Event status in bit encoded value. bit0 = Link Fault bit1 = Dying Gasp bit2 = Critical Event bit3 = Local Evaluating bit4 = Local Stable bit5 = Remote Evaluating bit6 = Remote Stable |
| I32 ahRemoteLpbkTimeout | 1.3.6.1.4.1.7342.2.1.7.1.14 | Integer32 | read-only | Used to get/set Remote Loopback timeout. Value is in seconds with range 0 - 300. |
| OCT ahLocalOUI | 1.3.6.1.4.1.7342.2.1.7.1.15 | OCTET STRING | read-only | Used to get the Organizational Unique ID of the local port. |
| OCT ahRemoteOUI | 1.3.6.1.4.1.7342.2.1.7.1.16 | OCTET STRING | read-only | Used to get the Organizational Unique ID of the remote port. |
| U32 ahErroredSymbolPeriodWindow | 1.3.6.1.4.1.7342.2.1.7.1.17 | Unsigned32 | read-write | Used to get or set errored symbol period window for the local port. |
| U32 ahErroredSymbolPeriodThreshold | 1.3.6.1.4.1.7342.2.1.7.1.18 | Unsigned32 | read-write | Used to get or set errored symbol period threshold for the local port. |
| U32 ahErroredFrameWindow | 1.3.6.1.4.1.7342.2.1.7.1.19 | Unsigned32 | read-write | Used to get or set the errored symbol window for the local port. |
| U32 ahErroredFrameThreshold | 1.3.6.1.4.1.7342.2.1.7.1.20 | Unsigned32 | read-write | Used to get or set the errored symbol threshold for the local port. |
| U32 ahErroredFramePeriodWindow | 1.3.6.1.4.1.7342.2.1.7.1.21 | Unsigned32 | read-write | Used to get or set the errored frame period window for the local port. |
| U32 ahErroredFramePeriodThreshold | 1.3.6.1.4.1.7342.2.1.7.1.22 | Unsigned32 | read-write | Used to get or set the errored frame period threshold for the local port. |
| U32 ahErroredFrameSecondsWindow | 1.3.6.1.4.1.7342.2.1.7.1.23 | Unsigned32 | read-write | Used to get or set the errored frame seconds window for the local port. |
| U32 ahErroredFrameSecondsThreshold | 1.3.6.1.4.1.7342.2.1.7.1.24 | Unsigned32 | read-write | Used to get or set the errored frame seconds threshold for the local port. |
| I32 ahRemoteLinkPort | 1.3.6.1.4.1.7342.2.1.7.1.25 | Integer32 | read-only | Used to get the port number of the remote partner. Value is in the Range 1-5. A zero port number indicates no connection or not supported |
| U32 ahSymbolErrorRunningTotal | 1.3.6.1.4.1.7342.2.1.7.1.26 | Unsigned32 | read-only | This object indicates the 802.3ah Symbol Error Running Total value from the last OAM sublayer reset or clear operation. A value of zero indicates that no symbol errors have been detected since the last reset or clear. For each symbol error detected the value of the object increments. |
| U32 ahSymbolErrorEventTotal | 1.3.6.1.4.1.7342.2.1.7.1.27 | Unsigned32 | read-only | This object indicates the number of 802.3ah Errored Symbol Period Event TLVs that have been generated since the OAM sublayer was reset or the counters have been cleared. A value of zero indicates that no Errored Symbol Period Event TLVs have been generated. For each Errored Symbol Period Event TLV generated the value of the object increments. |
| U32 ahFrameErrorRunningTotal | 1.3.6.1.4.1.7342.2.1.7.1.28 | Unsigned32 | read-only | This object indicates the sum of the 802.3ah errored frames that have been detected since the OAM sublayer was reset or clear operation. A value of zero indicates that no errored frames have been detected since the last reset or clear. For each errored frame the value of the object increments. |
| U32 ahFrameErrorEventTotal | 1.3.6.1.4.1.7342.2.1.7.1.29 | Unsigned32 | read-only | This object indicates the number of 802.3ah Errored Frame Event TLVs that have been generated since the OAM sublayer was reset or the counters have been cleared. A value of zero indicates that no Errored Frame Event TLVs have been generated. For each Errored Frame Event Event TLV generated the value of the object increments. |
| U32 ahFramePeriodRunningTotal | 1.3.6.1.4.1.7342.2.1.7.1.30 | Unsigned32 | read-only | This object indicates the sum of 802.3ah the frame errors that have been detected that have been since the OAM sublayer was reset or clear operation. A value of zero indicates that no errored frames have been detected since the last reset or clear. For each errored frame the value of the object increments. |
| U32 ahFramePeriodEventTotal | 1.3.6.1.4.1.7342.2.1.7.1.31 | Unsigned32 | read-only | This object indicates the number of 802.3ah Errored Frame Period Event TLVs that have been generated since the OAM sublayer was reset or the counters have been cleared. A value of zero indicates that no Errored Frame Period Event TLVs have been generated. For each Errored Symbol Period Event TLV generated the value of the object increments. |
| U32 ahFrameSecondsSummaryRunningTotal | 1.3.6.1.4.1.7342.2.1.7.1.32 | Unsigned32 | read-only | This object indicates the sum of the 802.3ah errored frame seconds that have been detected that have been since the OAM sublayer was reset or clear operation. A value of zero indicates that no errored frame seconds have been detected since the last reset or clear. For each errored frame the value of the object increments. |
| U32 ahFrameSecondsSummaryEventTotal | 1.3.6.1.4.1.7342.2.1.7.1.33 | Unsigned32 | read-only | This object indicates the number of 802.3ah Errored Frame Seconds Summary Event TLVs that have been generated since the OAM sublayer was reset or the counters have been cleared. A value of zero indicates that no Errored Frame Seconds Summary Event TLVs have been generated. For each Errored Symbol Period Event TLV generated the value of the object increments. |
| T/F ahClearStatistics | 1.3.6.1.4.1.7342.2.1.7.1.34 | TruthValue | read-write | This object when written clears the 802.3ah statistic counters associated with a specific port. When read the value always returns 'false'. Writing this value does not change any items in the configuration table. |
| U32 ahTransmissionRate | 1.3.6.1.4.1.7342.2.1.7.1.35 | Unsigned32 | read-write | This object sets maximum 802.3ah PDU transmission rate. The default value is 10 (10 frames per second) |
| U32 ahCriticalEventMode | 1.3.6.1.4.1.7342.2.1.7.1.36 | Unsigned32 | read-write | Used to get or set the state of the local critical event mode. 0 = local critical events not enabled 1 = local critical events are enabled |
| OCT ahCriticalEventTrapList | 1.3.6.1.4.1.7342.2.1.7.1.37 | OCTET STRING | read-write | Used to the SNMP traps which will cause the generation of a local critical event. It is a list of zero or more trap numbers separated by a comma or range, '..'. Example values: 5 5,110,112 100..110 5,110,90..95,100..105 The default value is an emtpy string, no SNMP traps generate a local critical event. |
| portSFPTable | 1.3.6.1.4.1.7342.2.1.8 | not-accessible | This is a table of AH parameter entries per port. | |
| portSFPEntry | 1.3.6.1.4.1.7342.2.1.8.1 | not-accessible | SFP port table. | |
| I32 portSFPstatus | 1.3.6.1.4.1.7342.2.1.8.1.1 | Integer32 | read-only | Used to get present or absence of SFP device. 0 = undefined 1 = notPresent 2 = present |
| OCT portSFPpageA0 | 1.3.6.1.4.1.7342.2.1.8.1.2 | OCTET STRING | read-only | Used to get SFP device EEPROM address A0 |
| OCT portSFPpageA2 | 1.3.6.1.4.1.7342.2.1.8.1.3 | OCTET STRING | read-only | Used to get SFP device EEPROM address A2 |
| OCT portSfpBitRate | 1.3.6.1.4.1.7342.2.1.8.1.4 | OCTET STRING | read-only | SFP Bitrate in Mbps |
| OCT portSfpVendorName | 1.3.6.1.4.1.7342.2.1.8.1.5 | OCTET STRING | read-only | SFP Vendor Name |
| OCT portSfpVendorPartNumber | 1.3.6.1.4.1.7342.2.1.8.1.6 | OCTET STRING | read-only | SFP Vendor Name |
| OCT portSfpVendorSerialNumber | 1.3.6.1.4.1.7342.2.1.8.1.7 | OCTET STRING | read-only | SFP Serial Number |
| OCT portSfpDateCode | 1.3.6.1.4.1.7342.2.1.8.1.8 | OCTET STRING | read-only | SFP Date Code |
| OCT portSfpTemperature | 1.3.6.1.4.1.7342.2.1.8.1.9 | OCTET STRING | read-only | SFP tempearture in degrees Centigrade |
| OCT portSfpVcc | 1.3.6.1.4.1.7342.2.1.8.1.10 | OCTET STRING | read-only | SFP VCC in volts |
| OCT portSfpBiasCurrent | 1.3.6.1.4.1.7342.2.1.8.1.11 | OCTET STRING | read-only | SFP Bias Current in millamps |
| OCT portSfpTxPower | 1.3.6.1.4.1.7342.2.1.8.1.12 | OCTET STRING | read-only | SFP Transmission power in dBm |
| OCT portSfpRxPower | 1.3.6.1.4.1.7342.2.1.8.1.13 | OCTET STRING | read-only | SFP Transmission power in dBm |
| userTable | 1.3.6.1.4.1.7342.2.1.9 | not-accessible | This is a table of SNMPv3 users. | |
| userEntry | 1.3.6.1.4.1.7342.2.1.9.1 | not-accessible | User table entry. | |
| I32 userIndex | 1.3.6.1.4.1.7342.2.1.9.1.1 | Integer32 | not-accessible | User table index |
| STR snmpv3UserName | 1.3.6.1.4.1.7342.2.1.9.1.2 | DisplayString | read-write | SNMPv3 user name. |
| I32 snmpv3SecurityLevel | 1.3.6.1.4.1.7342.2.1.9.1.3 | Integer32 | read-write | SNMPv3 security level 0 = undefined 1 = no authentication/no privacy 2 = authentication/no privacy 3 = authentication/privacy |
| OCT snmpv3AuthPassword | 1.3.6.1.4.1.7342.2.1.9.1.4 | OCTET STRING | read-write | SNMPv3 user authentication password. |
| OCT snmpv3PrivPassword | 1.3.6.1.4.1.7342.2.1.9.1.5 | OCTET STRING | read-write | SNMPv3 user privacy password. |
| I32 snmpv3UserType | 1.3.6.1.4.1.7342.2.1.9.1.6 | Integer32 | read-write | SNMPv3 User Type 0 = undefined 1 = admin 2 = read-write 3 = read-only 4 = deny |
| ostProtocolStatusTable | 1.3.6.1.4.1.7342.2.1.10 | not-accessible | This table supports the Serial, Telnet, FTP user session status. | |
| ostProtocolStatusEntry | 1.3.6.1.4.1.7342.2.1.10.1 | not-accessible | This is a user protocol table entry. | |
| U32 ostProtocolStatusIndex | 1.3.6.1.4.1.7342.2.1.10.1.1 | Unsigned32 | not-accessible | An index that is used to identify a specific user protocol session. The index should remain constant until the session is closed. |
| INT ostProtocolStatusType | 1.3.6.1.4.1.7342.2.1.10.1.2 | INTEGER | read-only | This object indicates the specific user protocol session identity state. serial (1) User protocol session type is the serial port telnet (2) User protocol session type is TELNET ftp (3) User protocol session type is FTP |
| INT ostProtocolStatusState | 1.3.6.1.4.1.7342.2.1.10.1.3 | INTEGER | read-only | This object indicates the status of the specific user protocol session state. inactive(1) User is currently inactive (reserved value, not used) active(2) User is currently authenticated and active lockedout(3) User is currently locked out for authentication and cannot become active until the locked out timeout expires and the user status goes back to idle. |
| INT ostProtocoManagementPort | 1.3.6.1.4.1.7342.2.1.10.1.4 | INTEGER | read-only | This object indicates the status of the specific user protocol session state. It is not applicable to the 'serial' interface or to a session type that is locked out. In these cases the object is returned with a value of 'notDefined'. notDefined(1) Management port is unknown or undefined mgt1(2) Management Port 1 association mgt2(3) Management Port 2 association |
| IP ostProtocolStatusIpAddress | 1.3.6.1.4.1.7342.2.1.10.1.5 | IpAddress | read-only | This object indicates the IP address of the specific user protocol session. It is not applicable to the 'serial' interface or to a session type that is locked out. In these cases this object is returned as '0.0.0.0'. |
| NUM ostProtocolStatusSessionOpenLockTime | 1.3.6.1.4.1.7342.2.1.10.1.6 | TimeInterval | read-only | The object indicates the time a specific user protocol session has been open or is locked out, in 0.01 seconds, based upon the value of ostProtocolStatusState. |
| ostEnvironmentalStatusTable | 1.3.6.1.4.1.7342.2.1.11 | not-accessible | This table supports the module environmental status objects. | |
| ostEnvironmentalStatusEntry | 1.3.6.1.4.1.7342.2.1.11.1 | not-accessible | This is an environmental table entry. | |
| INT ostEnvironmentalPs1Status | 1.3.6.1.4.1.7342.2.1.11.1.1 | INTEGER | read-only | This object indicates the status of Power Supply PS1 or PSA. notApplicable(0) Power Supply PS1/PSA is not supported notInstalled(1) Power Supply PS1/PSA is not installed installedNotPowered(2) Power Supply PS1/PSA is installed, but not powered installedPowered(3) Power Supply PS1/PSA is installed and powered |
| I32 ostEnvironmentalPs1VoltageIn | 1.3.6.1.4.1.7342.2.1.11.1.2 | Integer32 | read-only | This object indicates PS1/PSA voltage input in millivolts. A value of zero indicates that no voltage is applied or the power supply is incapable of supplying a voltage input reading. |
| U32 ostEnvironmentalPs1VoltageOut | 1.3.6.1.4.1.7342.2.1.11.1.3 | Unsigned32 | read-only | This object indicates PS1/PSA voltage output in millivolts. A value of zero indicates that no voltage is output or the power supply is incapable of supplying a voltage output reading. |
| U32 ostEnvironmentalPs1CurrentOut | 1.3.6.1.4.1.7342.2.1.11.1.4 | Unsigned32 | read-only | This object indicates PS1/PSA current output in millianmps. A value of zero indicates that no current is output or the power supply is incapable of supplying a current output reading. |
| INT ostEnvironmentalPs2Status | 1.3.6.1.4.1.7342.2.1.11.1.5 | INTEGER | read-only | This object indicates the status of Power Supply PS2 or PSB. notApplicable(0) Power Supply PS2/PSB is not supported notInstalled(1) Power Supply PS2/PSB is not installed installedNotPowered(2) Power Supply PS2/PSB is installed, but not powered installedPowered(3) Power Supply PS2/PSB is installed and powered |
| I32 ostEnvironmentalPs2VoltageIn | 1.3.6.1.4.1.7342.2.1.11.1.6 | Integer32 | read-only | This object indicates PS2/PSB voltage input in millivolts. A value of zero indicates that no voltage is applied or the power supply is incapable of supplying a voltage input reading. |
| U32 ostEnvironmentalPs2VoltageOut | 1.3.6.1.4.1.7342.2.1.11.1.7 | Unsigned32 | read-only | This object indicates PS2/PSB voltage output in millivolts. A value of zero indicates that no voltage is output or the power supply is incapable of supplying a voltage output reading. |
| U32 ostEnvironmentalPs2CurrentOut | 1.3.6.1.4.1.7342.2.1.11.1.8 | Unsigned32 | read-only | This object indicates PS2/PSB current output in millianmps. A value of zero indicates that no current is output or the power supply is incapable of supplying a current output reading. |
| I32 ostEnvironmentalTemperature | 1.3.6.1.4.1.7342.2.1.11.1.9 | Integer32 | read-only | This object indicates the module internal ambient temperature in degrees centigrade. A value of zero indicates that the current temperature is 0 degrees or the module incapable of supplying a temperature reading. |
| INT ostEnvironmentalFan1Status | 1.3.6.1.4.1.7342.2.1.11.1.10 | INTEGER | read-only | This object indicates the status of Fan 1. notApplicable(0) Fan 1 is not supported notInstalled(1) Fan 1 is not installed installedNotPowered(2) Fan 1 is installed, but not powered installedPowered(3) Fan 1 is installed and powered |
| U32 ostEnvironmentalFan1Speed | 1.3.6.1.4.1.7342.2.1.11.1.11 | Unsigned32 | read-only | This object indicates the speed of Fan 1 in RPM (revolutions per minute) A value of zero indicates that the current fan speed is 0 RPM or the fan is not supported or installed. |
| INT ostEnvironmentalFan2Status | 1.3.6.1.4.1.7342.2.1.11.1.12 | INTEGER | read-only | This object indicates the status of Fan 2. notApplicable(0) Fan 2 is not supported notInstalled(1) Fan 2 is not installed installedNotPowered(2) Fan 2 is installed, but not powered installedPowered(3) Fan 2 is installed and powered |
| U32 ostEnvironmentalFan2Speed | 1.3.6.1.4.1.7342.2.1.11.1.13 | Unsigned32 | read-only | This object indicates the speed of Fan 2 in RPM (revolutions per minute) A value of zero indicates that the current fan speed is 0 RPM or the fan is not supported or installed. |
| INT ostEnvironmentalFan3Status | 1.3.6.1.4.1.7342.2.1.11.1.14 | INTEGER | read-only | This object indicates the status of Fan 3. notApplicable(0) Fan 3 is not supported notInstalled(1) Fan 3 is not installed installedNotPowered(2) Fan 3 is installed, but not powered installedPowered(3) Fan 3 is installed and powered |
| U32 ostEnvironmentalFan3Speed | 1.3.6.1.4.1.7342.2.1.11.1.15 | Unsigned32 | read-only | This object indicates the speed of Fan 3 in RPM (revolutions per minute) A value of zero indicates that the current fan speed is 0 RPM or the fan is not supported or installed. |
| omnitronMIB | 1.3.6.1.4.1.7342.3 | Omnitron MIB for use with v5.2 iConverter Management Modules and NetOutlook Copyright 2015 Omnitron Systems Technology, Inc. All rights reserved | ||
| omnitronConformance | 1.3.6.1.4.1.7342.4 | |||
| omnitronCompliances | 1.3.6.1.4.1.7342.4.1 | |||
| omnitronCompliance | 1.3.6.1.4.1.7342.4.1.1 | The compliance statement for OMNITRON iConverter modules. | ||
| omnitronGroups | 1.3.6.1.4.1.7342.4.2 | |||
| omnitronGroup | 1.3.6.1.4.1.7342.4.2.1 | A collection of Omnitron objects. | ||
| omnitronSFPGroup | 1.3.6.1.4.1.7342.4.2.2 | A collection of Omnitron port SFP objects. | ||
| omnitronProducts | 1.3.6.1.4.1.7342.5 | |||
| managementModule | 1.3.6.1.4.1.7342.5.1 |
RFC description
Management objects for Omnitron iConverter platform including hardware revision, module status, and system configuration on optical converters.
Start monitoring Omnitron iConverter media converter chassis (hardware inventory/asset identity) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.