All MIBs › OMNI-gx2Dm200-MIB
Category: CATV and HFC
Description: Manages the Cisco/Scientific Atlanta GX2 Dm200 downstream RF modulator module status in HFC cable networks.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is OMNI-gx2Dm200-MIB?
OMNI-gx2Dm200-MIB is a vendor-specific SNMP module written for General Instrument Corporation's OmniStar GX2 hybrid fiber-coax (HFC) headend platform, specifically the OMNISTAR DM 1550 laser module return-path transmitter (device family gx2Dm200). It extends the shared hfcCommonTable with device-specific data organized into four tables -- gx2Dm200AnalogTable, gx2Dm200DigitalTable, gx2Dm200StatusTable, and gx2Dm200FactoryTable -- exposing analog readings such as dm200currentValueLaserPower, dm200currentValueLaserTemp, dm200currentValueTecCurrent, and dm200currentValueOffsetNomMonitor, each paired with high/low alarm thresholds and a dm200alarmState indicator. It also models digital status points (dm200valueRfInput, dm200valueOptOutput, dm200valueSbsControl) and factory/diagnostic counters (dm200bank1CRC, dm200hourMeter, dm200flashPrgCntA). It depends on GX2HFC-MIB for the parent gx2Dm200 object identifier and on NLSBBN-TRAPS-MIB for shared trap variable bindings, and is deployed alongside the broader OmniStar HFC network element MIB suite used by cable headend management systems; administrators can download the OMNI-gx2Dm200-MIB file to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in OMNI-gx2Dm200-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- General Instrument OmniStar GX2 HFC headend platform
- OMNISTAR DM 1550 return-path laser transmitter module
Monitoring Examples
An operator polls dm200currentValueLaserTemp and dm200alarmStateLaserTemp on the return-path transmitter to check the laser diode's operating temperature, and a shift into majorHighAlarm or majorLowAlarm state (rather than noAlarm) would indicate the laser module is overheating or under-driven and at risk of signal degradation or failure.
What Can Be Monitored
- Laser power, temperature, and TEC current analog levels with alarm thresholds
- RF input and optical output digital status
- Standby/SBS control state
- Factory CRC and flash/boot diagnostic counters
- Offset/nominal monitor and attenuation setting alarms
This MIB depends on
Related MIBs
Imported Objects
From GX2HFC-MIB
| gx2Dm200 | OBJECT-IDENTITY |
From NLSBBN-TRAPS-MIB
| trapChangedObjectId | OBJECT-TYPE |
| trapChangedValueDisplayString | OBJECT-TYPE |
| trapChangedValueInteger | OBJECT-TYPE |
| trapIdentifier | OBJECT-TYPE |
| trapNETrapLastTrapTimeStamp | OBJECT-TYPE |
| trapNetworkElemAdminState | OBJECT-TYPE |
| trapNetworkElemAlarmStatus | OBJECT-TYPE |
| trapNetworkElemAvailStatus | OBJECT-TYPE |
| trapNetworkElemModelNumber | OBJECT-TYPE |
| trapNetworkElemOperState | OBJECT-TYPE |
| trapNetworkElemSerialNum | OBJECT-TYPE |
| trapPerceivedSeverity | OBJECT-TYPE |
| trapText | OBJECT-TYPE |
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter |
From RFC1213-MIB
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| NTF trapDM200ConfigChangeInteger | 1.3.6.1.4.1.1166.6.1.2.19.0.1 | This trap is issued if configuration of a single variable with integer type was changed (via ANY interface). TrapChangedValueInteger variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapDM200ConfigChangeDisplayString | 1.3.6.1.4.1.1166.6.1.2.19.0.2 | This trap is issued if configuration of a single variable with DispalayString type was changed (via ANY interface). TrapChangedValueDisplayString variable may contain current reading of that variable. trapPerceivedSeverity - 'indeterminate' | ||
| NTF trapDM200fanCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.19.0.3 | This trap is issued when the Fan Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapDM200ModuleTempAlarm | 1.3.6.1.4.1.1166.6.1.2.19.0.4 | This trap is issued when the Module Temperature parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapDM200omiOffsetAlarm | 1.3.6.1.4.1.1166.6.1.2.19.0.5 | This trap is issued when the OMI Offset goes out of range. | ||
| NTF trapDM200tecCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.19.0.6 | This trap is issued when the TEC Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapDM200LaserCurrentAlarm | 1.3.6.1.4.1.1166.6.1.2.19.0.7 | This trap is issued when the Laser Current parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapDM200LaserTempAlarm | 1.3.6.1.4.1.1166.6.1.2.19.0.8 | This trap is issued when the Laser Temp parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapDM200LaserPowerAlarm | 1.3.6.1.4.1.1166.6.1.2.19.0.9 | This trap is issued when the Laser Power parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapDM200FlashAlarm | 1.3.6.1.4.1.1166.6.1.2.19.0.10 | This trap is issued when the Laser Modules detects an error during Flash memory operations. | ||
| NTF trapDM200BankBootAlarm | 1.3.6.1.4.1.1166.6.1.2.19.0.11 | This trap is issued when the Laser Modules detects an error while booting from bank 0 or bank 1. | ||
| NTF trapDM200AlarmDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.19.0.12 | This trap is issued when the Alarm Data CRC is incorrect. | ||
| NTF trapDM200FactoryDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.19.0.13 | This trap is issued when the Factory Data CRC is incorrect. | ||
| NTF trapDM200CalDataCRCAlarm | 1.3.6.1.4.1.1166.6.1.2.19.0.14 | This trap is issued when the Cal Data CRC is incorrect. | ||
| NTF trapDM200ResetFacDefault | 1.3.6.1.4.1.1166.6.1.2.19.0.15 | This trap is issued when the DM200 resets to factory defaults | ||
| NTF trapDM200UserRFOffAlarm | 1.3.6.1.4.1.1166.6.1.2.19.0.16 | This trap is issued when the the User RF is turned off. | ||
| NTF trapDM200UserOpticalOffAlarm | 1.3.6.1.4.1.1166.6.1.2.19.0.17 | This trap is issued when the User Optical Power is turned off. | ||
| NTF trapDM200UserSBSOffAlarm | 1.3.6.1.4.1.1166.6.1.2.19.0.18 | This trap is issued when the User SBS is turned off. | ||
| NTF trapDM200RFInputAlarm | 1.3.6.1.4.1.1166.6.1.2.19.0.19 | This trap is issued when the Laser Modules RF input parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| NTF trapDM200RFOverloadAlarm | 1.3.6.1.4.1.1166.6.1.2.19.0.20 | This trap is issued when the Laser Modules RF overload parameter goes out of range. trapAdditionalInfoInteger variable contains current reading of the this parameter. | ||
| gx2Dm200Descriptor | 1.3.6.1.4.1.1166.6.1.2.19.1 | |||
| gx2Dm200AnalogTable | 1.3.6.1.4.1.1166.6.1.2.19.2 | not-accessible | This table contains gx2Dm200 specific parameters with nominal and current values. | |
| gx2Dm200AnalogEntry | 1.3.6.1.4.1.1166.6.1.2.19.2.1 | not-accessible | This list contains the analog parameters and descriptions. | |
| INT gx2Dm200AnalogTableIndex | 1.3.6.1.4.1.1166.6.1.2.19.2.1.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR dm200labelOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.19.2.1.2 | DisplayString | read-only | The value of this object provides the label of the Offset Monitor Analog parameter. |
| STR dm200uomOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.19.2.1.3 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Offset Monitor Analog parameter. The unit of measure for this parameter is dB |
| FLO dm200majorHighOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.19.2.1.4 | Float | read-only | The value of this object provides the Major High alarm value of the Offset Monitor Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO dm200majorLowOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.19.2.1.5 | Float | read-only | The value of this object provides the Major Low alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO dm200minorHighOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.19.2.1.6 | Float | read-only | The value of this object provides the Minor High alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO dm200minorLowOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.19.2.1.7 | Float | read-only | The value of this object provides the Minor Low alarm value of the Offset Monitor Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO dm200currentValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.19.2.1.8 | Float | read-only | The value of this object provides the Current value of the Offset Monitor Power Analog parameter. |
| INT dm200stateFlagOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.19.2.1.9 | INTEGER | read-only | The value of this object provides the state of the Offset Monitor Power Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dm200minValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.19.2.1.10 | Float | read-only | The value of this object provides the minimum value the Offset Monitor Power Analog parameter can achive. |
| FLO dm200maxValueOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.19.2.1.11 | Float | read-only | The value of this object provides the maximum value the Offset Monitor Power Analog parameter can achive. |
| INT dm200alarmStateOffsetNomMonitor | 1.3.6.1.4.1.1166.6.1.2.19.2.1.12 | INTEGER | read-only | The value of this object provides the curent alarm state of the Offset Monitor Power Analog parameter. |
| STR dm200labelAttenSetting | 1.3.6.1.4.1.1166.6.1.2.19.2.1.13 | DisplayString | read-only | The value of this object provides the label of the Attenuator Setting Current Analog parameter. |
| STR dm200uomAttenSetting | 1.3.6.1.4.1.1166.6.1.2.19.2.1.14 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Attenuator Setting Analog parameter. The unit of measure for this parameter is dB |
| FLO dm200majorHighAttenSetting | 1.3.6.1.4.1.1166.6.1.2.19.2.1.15 | Float | read-only | The value of this object provides the Major High alarm value of the Attenuator Setting Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO dm200majorLowAttenSetting | 1.3.6.1.4.1.1166.6.1.2.19.2.1.16 | Float | read-only | The value of this object provides the Major Low alarm value of the Attenuator Setting Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO dm200minorHighAttenSetting | 1.3.6.1.4.1.1166.6.1.2.19.2.1.17 | Float | read-only | The value of this object provides the Minor High alarm value of the Attenuator Setting Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO dm200minorLowAttenSetting | 1.3.6.1.4.1.1166.6.1.2.19.2.1.18 | Float | read-only | The value of this object provides the Minor Low alarm value of the Attenuator Setting Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO dm200currentValueAttenSetting | 1.3.6.1.4.1.1166.6.1.2.19.2.1.19 | Float | read-write | The value of this object provides the Current value of the Attenuator Setting Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm200stateFlagAttenSetting | 1.3.6.1.4.1.1166.6.1.2.19.2.1.20 | INTEGER | read-only | The value of this object provides the state of the Attenuator Setting Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dm200minValueAttenSetting | 1.3.6.1.4.1.1166.6.1.2.19.2.1.21 | Float | read-only | The value of this object provides the minimum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| FLO dm200maxValueAttenSetting | 1.3.6.1.4.1.1166.6.1.2.19.2.1.22 | Float | read-only | The value of this object provides the maximum value the Attenuator Setting Analog parameter can achive. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm200alarmStateAttenSetting | 1.3.6.1.4.1.1166.6.1.2.19.2.1.23 | INTEGER | read-only | The value of this object provides the curent alarm state of the Attenuator Setting Analog parameter. |
| STR dm200labelLaserPower | 1.3.6.1.4.1.1166.6.1.2.19.2.1.24 | DisplayString | read-only | The value of this object provides the label of the Laser Optical Power Analog parameter. |
| STR dm200uomLaserPower | 1.3.6.1.4.1.1166.6.1.2.19.2.1.25 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Optical Power Analog parameter. The unit of measure for this parameter is dBm |
| FLO dm200majorHighLaserPower | 1.3.6.1.4.1.1166.6.1.2.19.2.1.26 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Optical Power Analog parameter. |
| FLO dm200majorLowLaserPower | 1.3.6.1.4.1.1166.6.1.2.19.2.1.27 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Optical Power Analog parameter. |
| FLO dm200minorHighLaserPower | 1.3.6.1.4.1.1166.6.1.2.19.2.1.28 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Optical Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO dm200minorLowLaserPower | 1.3.6.1.4.1.1166.6.1.2.19.2.1.29 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Optical Power Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO dm200currentValueLaserPower | 1.3.6.1.4.1.1166.6.1.2.19.2.1.30 | Float | read-only | The value of this object provides the Current value of the Laser Optical Power Analog parameter. This value is a floating point number that is represented as an IEEE 32 bit number. |
| INT dm200stateFlagLaserPower | 1.3.6.1.4.1.1166.6.1.2.19.2.1.31 | INTEGER | read-only | The value of this object provides the state of the Laser Optical Power Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dm200minValueLaserPower | 1.3.6.1.4.1.1166.6.1.2.19.2.1.32 | Float | read-only | The value of this object provides the minimum value the Laser Optical Power Analog parameter can achive. |
| FLO dm200maxValueLaserPower | 1.3.6.1.4.1.1166.6.1.2.19.2.1.33 | Float | read-only | The value of this object provides the maximum value the Laser Optical Power Analog parameter can achive. |
| INT dm200alarmStateLaserPower | 1.3.6.1.4.1.1166.6.1.2.19.2.1.34 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Optical Power Analog parameter. |
| STR dm200labelLaserTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.35 | DisplayString | read-only | The value of this object provides the label of the Laser Temperature Analog parameter. |
| STR dm200uomLaserTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.36 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Temperature Analog parameter. The unit of measure for this parameter is degrees C |
| FLO dm200majorHighLaserTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.37 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Temperature Analog parameter. |
| FLO dm200majorLowLaserTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.38 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Temperature Analog parameter. |
| FLO dm200minorHighLaserTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.39 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Temperature Analog parameter. |
| FLO dm200minorLowLaserTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.40 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Temperature Analog parameter. |
| FLO dm200currentValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.41 | Float | read-only | The value of this object provides the Current value of the Laser Temperature Analog parameter. |
| INT dm200stateFlagLaserTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.42 | INTEGER | read-only | The value of this object provides the state of the Laser Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dm200minValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.43 | Float | read-only | The value of this object provides the minimum value the Laser Temperature Analog parameter can achive. |
| FLO dm200maxValueLaserTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.44 | Float | read-only | The value of this object provides the maximum value the Laser Temperature Analog parameter can achive. |
| INT dm200alarmStateLaserTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.45 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Temperature Analog parameter. |
| STR dm200labelLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.46 | DisplayString | read-only | The value of this object provides the label of the Laser Bias Current Analog parameter. |
| STR dm200uomLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.47 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Laser Bias Current Analog parameter. The unit of measure for this parameter is mA |
| FLO dm200majorHighLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.48 | Float | read-only | The value of this object provides the Major High alarm value of the Laser Bias Current Analog parameter. |
| FLO dm200majorLowLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.49 | Float | read-only | The value of this object provides the Major Low alarm value of the Laser Bias Current Analog parameter. |
| FLO dm200minorHighLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.50 | Float | read-only | The value of this object provides the Minor High alarm value of the Laser Bias Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO dm200minorLowLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.51 | Float | read-only | The value of this object provides the Minor Low alarm value of the Laser Bias Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO dm200currentValueLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.52 | Float | read-only | The value of this object provides the Current value of the Laser Bias Current Analog parameter. |
| INT dm200stateFlagLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.53 | INTEGER | read-only | The value of this object provides the state of the Laser Bias Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dm200minValueLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.54 | Float | read-only | The value of this object provides the minimum value the Laser Bias Current Analog parameter can achive. |
| FLO dm200maxValueLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.55 | Float | read-only | The value of this object provides the maximum value the Laser Bias Current Analog parameter can achive. |
| INT dm200alarmStateLaserCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.56 | INTEGER | read-only | The value of this object provides the curent alarm state of the Laser Bias Current Analog parameter. |
| STR dm200labelTecCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.57 | DisplayString | read-only | The value of this object provides the label of the TEC Current Analog parameter. |
| STR dm200uomTecCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.58 | DisplayString | read-only | The value of this object provides the Unit of Measure of the TEC Current Analog parameter. The unit of measure for this parameter is mA |
| FLO dm200majorHighTecCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.59 | Float | read-only | The value of this object provides the Major High alarm value of the TEC Current Analog parameter. |
| FLO dm200majorLowTecCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.60 | Float | read-only | The value of this object provides the Major Low alarm value of the TEC Current Analog parameter. |
| FLO dm200minorHighTecCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.61 | Float | read-only | The value of this object provides the Minor High alarm value of the TEC Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO dm200minorLowTecCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.62 | Float | read-only | The value of this object provides the Minor Low alarm value of the TEC Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO dm200currentValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.63 | Float | read-only | The value of this object provides the Current value of the TEC Current Analog parameter. |
| INT dm200stateFlagTecCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.64 | INTEGER | read-only | The value of this object provides the state of the TEC Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dm200minValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.65 | Float | read-only | The value of this object provides the minimum value the TEC Current Analog parameter can achive. |
| FLO dm200maxValueTecCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.66 | Float | read-only | The value of this object provides the maximum value the TEC Current Analog parameter can achive. |
| INT dm200alarmStateTecCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.67 | INTEGER | read-only | The value of this object provides the curent alarm state of the TEC Current Analog parameter. |
| STR dm200labelModTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.68 | DisplayString | read-only | The value of this object provides the label of the Module Temperature Analog parameter. |
| STR dm200uomModTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.69 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Module Temperature Analog parameter. The unit of measure for this parameter is degrees C |
| FLO dm200majorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.70 | Float | read-only | The value of this object provides the Major High alarm value of the Module Temperature Analog parameter. |
| FLO dm200majorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.71 | Float | read-only | The value of this object provides the Major Low alarm value of the Module Temperature Analog parameter. |
| FLO dm200minorHighModTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.72 | Float | read-only | The value of this object provides the Minor High alarm value of the Module Temperature Analog parameter. |
| FLO dm200minorLowModTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.73 | Float | read-only | The value of this object provides the Minor Low alarm value of the Module Temperature Analog parameter. |
| FLO dm200currentValueModTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.74 | Float | read-only | The value of this object provides the Current value of the Module Temperature Analog parameter. |
| INT dm200stateFlagModTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.75 | INTEGER | read-only | The value of this object provides the state of the Module Temperature Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dm200minValueModTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.76 | Float | read-only | The value of this object provides the minimum value the Module Temperature Analog parameter can achive. |
| FLO dm200maxValueModTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.77 | Float | read-only | The value of this object provides the maximum value the Module Temperature Analog parameter can achive. |
| INT dm200alarmStateModTemp | 1.3.6.1.4.1.1166.6.1.2.19.2.1.78 | INTEGER | read-only | The value of this object provides the curent alarm state of the Module Temperature Analog parameter. |
| STR dm200labelFanCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.79 | DisplayString | read-only | The value of this object provides the label of the Fan Current Analog parameter. |
| STR dm200uomFanCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.80 | DisplayString | read-only | The value of this object provides the Unit of Measure of the Fan Current Analog parameter. The unit of measure for this parameter is mA |
| FLO dm200majorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.81 | Float | read-only | The value of this object provides the Major High alarm value of the Fan Current Analog parameter. |
| FLO dm200majorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.82 | Float | read-only | The value of this object provides the Major Low alarm value of the Fan Current Analog parameter. |
| FLO dm200minorHighFanCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.83 | Float | read-only | The value of this object provides the Minor High alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO dm200minorLowFanCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.84 | Float | read-only | The value of this object provides the Minor Low alarm value of the Fan Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence. |
| FLO dm200currentValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.85 | Float | read-only | The value of this object provides the Current value of the Fan Current Analog parameter. |
| INT dm200stateFlagFanCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.86 | INTEGER | read-only | The value of this object provides the state of the Fan Current Analog parameter. (1-hidden 2-read-only, 3-updateable). |
| FLO dm200minValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.87 | Float | read-only | The value of this object provides the minimum value the Fan Current Analog parameter can achive. |
| FLO dm200maxValueFanCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.88 | Float | read-only | The value of this object provides the maximum value the Fan Current Analog parameter can achive. |
| INT dm200alarmStateFanCurrent | 1.3.6.1.4.1.1166.6.1.2.19.2.1.89 | INTEGER | read-only | The value of this object provides the curent alarm state of the Fan Current Analog parameter. |
| gx2Dm200DigitalTable | 1.3.6.1.4.1.1166.6.1.2.19.3 | not-accessible | This table contains gx2Dm200m specific parameters with nominal and current values. | |
| gx2Dm200DigitalEntry | 1.3.6.1.4.1.1166.6.1.2.19.3.2 | not-accessible | This list contains digital parameters and descriptions. | |
| INT gx2Dm200DigitalTableIndex | 1.3.6.1.4.1.1166.6.1.2.19.3.2.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR dm200labelRfInput | 1.3.6.1.4.1.1166.6.1.2.19.3.2.2 | DisplayString | read-only | The value of this object provides the label of the RF Input Control Digital parameter. |
| STR dm200enumRfInput | 1.3.6.1.4.1.1166.6.1.2.19.3.2.3 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT dm200valueRfInput | 1.3.6.1.4.1.1166.6.1.2.19.3.2.4 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT dm200stateflagRfInput | 1.3.6.1.4.1.1166.6.1.2.19.3.2.5 | INTEGER | read-only | The value of this object provides the state of the RF Input Control Digital parameter. (1-hidden 2-read-only, 3-updateable). |
| STR dm200labelOptOutput | 1.3.6.1.4.1.1166.6.1.2.19.3.2.6 | DisplayString | read-only | The value of this object provides the label of the Optical Output Control Digital parameter. |
| STR dm200enumOptOutput | 1.3.6.1.4.1.1166.6.1.2.19.3.2.7 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT dm200valueOptOutput | 1.3.6.1.4.1.1166.6.1.2.19.3.2.8 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT dm200stateflagOptOutput | 1.3.6.1.4.1.1166.6.1.2.19.3.2.9 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR dm200labelSbsControl | 1.3.6.1.4.1.1166.6.1.2.19.3.2.10 | DisplayString | read-only | The value of this object provides the label of the SBS Control Digital parameter. |
| STR dm200enumSbsControl | 1.3.6.1.4.1.1166.6.1.2.19.3.2.11 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1. |
| INT dm200valueSbsControl | 1.3.6.1.4.1.1166.6.1.2.19.3.2.12 | INTEGER | read-write | The value of this object is the current value of the parameter. |
| INT dm200stateflagSbsControl | 1.3.6.1.4.1.1166.6.1.2.19.3.2.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR dm200labelFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.19.3.2.14 | DisplayString | read-only | The value of this object provides the label of the Factory Default Digital parameter. |
| STR dm200enumFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.19.3.2.15 | DisplayString | read-only | The value of this object represents the Enumeration values possible for the Digital parameter. Each Enumerated values is separated by a common. The first value has a enumerated value of 1.. |
| INT dm200valueFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.19.3.2.16 | INTEGER | read-write | The value of this object is the current value of the parameter. Return value is meaningless |
| INT dm200stateflagFactoryDefault | 1.3.6.1.4.1.1166.6.1.2.19.3.2.17 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| gx2Dm200StatusTable | 1.3.6.1.4.1.1166.6.1.2.19.4 | not-accessible | This table contains gx2Dm200 specific parameters with nominal and current values. | |
| gx2Dm200StatusEntry | 1.3.6.1.4.1.1166.6.1.2.19.4.3 | not-accessible | This list contains Status parameters and descriptions. | |
| INT gx2Dm200StatusTableIndex | 1.3.6.1.4.1.1166.6.1.2.19.4.3.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| STR dm200labelBoot | 1.3.6.1.4.1.1166.6.1.2.19.4.3.2 | DisplayString | read-only | The value of this object provides the label of the Boot Status Status parameter. |
| INT dm200valueBoot | 1.3.6.1.4.1.1166.6.1.2.19.4.3.3 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT dm200stateflagBoot | 1.3.6.1.4.1.1166.6.1.2.19.4.3.4 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR dm200labelFlash | 1.3.6.1.4.1.1166.6.1.2.19.4.3.5 | DisplayString | read-only | The value of this object provides the label of the Flash Status Status parameter. |
| INT dm200valueFlash | 1.3.6.1.4.1.1166.6.1.2.19.4.3.6 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT dm200stateflagFlash | 1.3.6.1.4.1.1166.6.1.2.19.4.3.7 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR dm200labelFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.19.4.3.8 | DisplayString | read-only | The value of this object provides the label of the Factory Data CRC Status parameter. |
| INT dm200valueFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.19.4.3.9 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT dm200stateflagFactoryDataCRC | 1.3.6.1.4.1.1166.6.1.2.19.4.3.10 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR dm200labelLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.19.4.3.11 | DisplayString | read-only | The value of this object provides the label of the Laser Data CRC Status parameter. |
| INT dm200valueLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.19.4.3.12 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT dm200stateflagLaserDataCRC | 1.3.6.1.4.1.1166.6.1.2.19.4.3.13 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR dm200labelAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.19.4.3.14 | DisplayString | read-only | The value of this object provides the label of the Alarm Data Crc parameter. |
| INT dm200valueAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.19.4.3.15 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT dm200stateflagAlarmDataCrc | 1.3.6.1.4.1.1166.6.1.2.19.4.3.16 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| STR dm200labelRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.19.4.3.17 | DisplayString | read-only | The value of this object provides the label of the Alarm Data Crc parameter. |
| INT dm200valueRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.19.4.3.18 | INTEGER | read-only | The value of this object provides the current state of the parameter (1-ok, 2-undetermined 3-warning, 4-minor, 5-major, 6-critical). |
| INT dm200stateflagRFInputStatus | 1.3.6.1.4.1.1166.6.1.2.19.4.3.19 | INTEGER | read-only | The value of this object provides the state of the the parameter. (1-hidden, 2-read-only, 3-updateable). |
| gx2Dm200FactoryTable | 1.3.6.1.4.1.1166.6.1.2.19.5 | not-accessible | This table contains gx2Dm200 specific parameters with nominal and current values. | |
| gx2Dm200FactoryEntry | 1.3.6.1.4.1.1166.6.1.2.19.5.4 | not-accessible | This list contains Factory parameters and descriptions. | |
| INT gx2Dm200FactoryTableIndex | 1.3.6.1.4.1.1166.6.1.2.19.5.4.1 | INTEGER | read-only | The value of this object identifies the network element. This index is equal to the hfcCommonTableIndex for the same element. |
| INT dm200bootControlByte | 1.3.6.1.4.1.1166.6.1.2.19.5.4.2 | INTEGER | read-only | The value of this object indicates which bank the firmware is currently being boot from. |
| INT dm200bootStatusByte | 1.3.6.1.4.1.1166.6.1.2.19.5.4.3 | INTEGER | read-only | This object indicates the status of the last boot. Bit 2 = Bank 0/1 Active (0 = Bank 0, 1 = Bank 1), Bit 1 = Bank 1 Fail and Bit 0 = Bank 0 Fail (0 = Pass, 1 = Fail) |
| INT dm200bank1CRC | 1.3.6.1.4.1.1166.6.1.2.19.5.4.4 | INTEGER | read-only | This object provides the CRC code of bank 0. The display formate for the data is Hex. |
| INT dm200bank2CRC | 1.3.6.1.4.1.1166.6.1.2.19.5.4.5 | INTEGER | read-only | This object provides the CRC code of bank 1.The display formate for the data is Hex. |
| INT dm200prgEEPROMByte | 1.3.6.1.4.1.1166.6.1.2.19.5.4.6 | INTEGER | read-only | This object indicates if the EEPROM has been programmed |
| INT dm200factoryCRC | 1.3.6.1.4.1.1166.6.1.2.19.5.4.7 | INTEGER | read-only | This object provides the CRC code for the Factory data. |
| INT dm200calculateCRC | 1.3.6.1.4.1.1166.6.1.2.19.5.4.8 | INTEGER | read-only | This object indicates which of the Enums will have the CRC calculated. |
| INT dm200hourMeter | 1.3.6.1.4.1.1166.6.1.2.19.5.4.9 | INTEGER | read-only | This object provides the hour meter reading of the module. |
| INT dm200flashPrgCntA | 1.3.6.1.4.1.1166.6.1.2.19.5.4.10 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| INT dm200flashPrgCntB | 1.3.6.1.4.1.1166.6.1.2.19.5.4.11 | INTEGER | read-only | This object provides the number of times Bank 1 flash has been programmed. |
| STR dm200flashBankARev | 1.3.6.1.4.1.1166.6.1.2.19.5.4.12 | DisplayString | read-only | This object provides the revision of flash bank 0. The rev is 2 characters. |
| STR dm200flashBankBRev | 1.3.6.1.4.1.1166.6.1.2.19.5.4.13 | DisplayString | read-only | This object provides the revision of flash bank 1. The rev is 2 characters. |
RFC description
Management MIB for Omnistar GX2 DM200 1550nm laser modules and HFC network elements.
Start monitoring General Instrument OmniStar GX2 HFC headend platform (OMNISTAR DM 1550 return-path laser transmitter) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.