All MIBs › OMNI-gx2Dm200-MIB › dm200minorHighLaserCurrent
dm200minorHighLaserCurrent
Module: OMNI-gx2Dm200-MIB
OID (symbolic): OMNI-gx2Dm200-MIB::dm200minorHighLaserCurrent
OID (numeric): 1.3.6.1.4.1.1166.6.1.2.19.2.1.50
Node type: OBJECT-TYPE
Type: Float
Access: read-only
Description: The value of this object provides the Minor High alarm value of the Laser Bias Current Analog parameter. This object is not used by this module and always returns invalid float value of 0xFFFFFFFF . This object is kept here for persistence.
What is dm200minorHighLaserCurrent?
This minor-high alarm threshold for the laser bias current parameter is marked obsolete in this MIB and, per the source DESCRIPTION, always reads back an invalid float (0xFFFFFFFF); it exists only so older management stations that expect the column don't error out.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.19.2.1.50 snmpwalk -v2c -c public <target> OMNI-gx2Dm200-MIB::dm200minorHighLaserCurrent
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1166.6.1.2.19.2.1.50.1 snmpget -v2c -c public <target> OMNI-gx2Dm200-MIB::dm200minorHighLaserCurrent.1
Start monitoring General Instrument OmniStar GX2 HFC headend platform (OMNISTAR DM 1550 return-path laser transmitter) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the OMNI-gx2Dm200-MIB::dm200minorHighLaserCurrent OID value, configure state conditions and alerts, and monitor any General Instrument OmniStar GX2 HFC headend platform (OMNISTAR DM 1550 return-path laser transmitter) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1166 | gi | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6 | motproxies | BCS-IDENT-MIB |
| 1.3.6.1.4.1.1166.6.1 | hfc | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2 | hfcDevices | GX2HFC-MIB |
| 1.3.6.1.4.1.1166.6.1.2.19 | gx2Dm200 | GX2HFC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1166.6.1.2.19.2 | gx2Dm200AnalogTable | OMNI-gx2Dm200-MIB |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1 | gx2Dm200AnalogEntry | OMNI-gx2Dm200-MIB |
| 1.3.6.1.4.1.1166.6.1.2.19.2.1.50 | dm200minorHighLaserCurrent | OMNI-gx2Dm200-MIB |