All MIBs › MYLEXRAID-MIB
Category: Storage
Description: Monitors Mylex RAID controller disk array configuration, health, and event status.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is MYLEXRAID-MIB?
MYLEXRAID-MIB is a Mylex proprietary MIB, built on the DMTF standard component framework (dmtfStd/dmtfComponents), for monitoring Mylex RAID storage controllers used in servers. It exposes controller-level identification and capability data — a2ControllerNumber, a2FirmwareRevision, configured vs. actual channel counts, maximum logical drives, and I/O transfer/command limits — as well as operational state (a2OperationalState). This MIB is explicitly aimed at monitoring the hardware/firmware health of the RAID controller itself, most notably a2OperationalState (online/degraded/failed) and a2FirmwareRevision (confirming the firmware version in service), critical for detecting a failed or misconfigured storage controller before it causes disk-array data loss. It is built on the DMTF (Distributed Management Task Force) common information model conventions, indicating a standards-influenced structure beneath the vendor-specific objects. It is deployed on servers equipped with Mylex RAID controller cards for disk array management. Engineers can download the MYLEXRAID-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in MYLEXRAID-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Mylex RAID controller
- server with Mylex disk array card
Monitoring Examples
An administrator polls a2OperationalState under tControllerInformation/eControllerInformation to confirm the RAID controller (identified by a2ControllerNumber) is in a healthy operating state, cross-checking a2ConfiguredChannels against a2ActualChannels to detect a channel that failed to initialize; a mismatch there, or an a2OperationalState indicating degraded/failed, signals a RAID controller hardware problem requiring attention before it affects the attached disk array.
What Can Be Monitored
- RAID controller operational state
- firmware revision
- configured vs. actual channel count
- maximum logical drives supported
- I/O request/command limits
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| enterprises |
From RFC1213-MIB
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| mylex | 1.3.6.1.4.1.1608 | |||
| dmtfStd | 1.3.6.1.4.1.1608.1 | |||
| dmtfComponents | 1.3.6.1.4.1.1608.1.1 | |||
| dmtfGroups | 1.3.6.1.4.1.1608.1.1.1 | |||
| tControllerInformation | 1.3.6.1.4.1.1608.1.1.1.2 | not-accessible | This group provides Controller Information. | |
| eControllerInformation | 1.3.6.1.4.1.1608.1.1.1.2.1 | not-accessible | ||
| NUM a2ControllerNumber | 1.3.6.1.4.1.1608.1.1.1.2.1.1 | DmiInteger | read-only | Controller Number assigned to this controller by the device driver. |
| INT a2OperationalState | 1.3.6.1.4.1.1608.1.1.1.2.1.2 | INTEGER | read-only | Operational state of this controller as seen by the device driver. |
| STR a2FirmwareRevision | 1.3.6.1.4.1.1608.1.1.1.2.1.3 | DmiDisplaystring | read-only | Controller Firmware Revision. |
| NUM a2ConfiguredChannels | 1.3.6.1.4.1.1608.1.1.1.2.1.4 | DmiInteger | read-only | Number of Channels that are part of controller configuration. |
| NUM a2ActualChannels | 1.3.6.1.4.1.1608.1.1.1.2.1.5 | DmiInteger | read-only | Number of Channels that are physically present on-board the controller. |
| NUM a2MaximumLogicalDrives | 1.3.6.1.4.1.1608.1.1.1.2.1.6 | DmiInteger | read-only | Maximum number of logical drives that can be configured on this controller. |
| NUM a2MaximumTargetsPerChannel | 1.3.6.1.4.1.1608.1.1.1.2.1.7 | DmiInteger | read-only | Maximum Number of Physical Target IDs supported per Channel |
| NUM a2MaximumTaggedRequests | 1.3.6.1.4.1.1608.1.1.1.2.1.8 | DmiInteger | read-only | Maximum Number of Tagged requests that may be sent to a Hard disk device by Controller Firmware. |
| NUM a2MaximumDataTransferSizePerIoRequestInK | 1.3.6.1.4.1.1608.1.1.1.2.1.9 | DmiInteger | read-only | Maximum amount of data that can be transferred per a single IO request - in KB. |
| NUM a2MaximumConcurrentCommands | 1.3.6.1.4.1.1608.1.1.1.2.1.10 | DmiInteger | read-only | Maximum number of requests that can be sent to the controller simultaneouly. |
| NUM a2RebuildRate | 1.3.6.1.4.1.1608.1.1.1.2.1.11 | DmiInteger | read-only | Value of Rebuild Rate. |
| NUM a2LogicalSectorSizeInBytes | 1.3.6.1.4.1.1608.1.1.1.2.1.12 | DmiInteger | read-only | Logical Sector Size in Bytes (Default: 512 bytes). |
| NUM a2PhysicalSectorSizeInBytes | 1.3.6.1.4.1.1608.1.1.1.2.1.13 | DmiInteger | read-only | Physical Sector Size in Bytes (Default: 512 bytes). |
| NUM a2CacheLineSizeInBytes | 1.3.6.1.4.1.1608.1.1.1.2.1.14 | DmiInteger | read-only | Cache Line Size in Bytes. |
| NUM a2CacheSizeInMb | 1.3.6.1.4.1.1608.1.1.1.2.1.15 | DmiInteger | read-only | Size of Controller Cache Module - in MB. |
| INT a2CacheMemoryType | 1.3.6.1.4.1.1608.1.1.1.2.1.16 | INTEGER | read-only | Controller Cache Memory Type. |
| NUM a2EpromSizeInKb | 1.3.6.1.4.1.1608.1.1.1.2.1.17 | DmiInteger | read-only | Size of Controller EPROM Module - in KB. |
| INT a2BusType | 1.3.6.1.4.1.1608.1.1.1.2.1.18 | INTEGER | read-only | Controller - System Bus Interface Type. |
| INT a2ControllerClass | 1.3.6.1.4.1.1608.1.1.1.2.1.19 | INTEGER | read-only | Controller Class Type. |
| INT a2ControllerModel | 1.3.6.1.4.1.1608.1.1.1.2.1.20 | INTEGER | read-only | Controller Model Type. |
| NUM a2SystemBusNumber | 1.3.6.1.4.1.1608.1.1.1.2.1.21 | DmiInteger | read-only | System Bus Number, for the bus the controller is interfacing with. This value is supplied by the Operating system and may not be defined for all operating systems. |
| NUM a2SlotNumber | 1.3.6.1.4.1.1608.1.1.1.2.1.22 | DmiInteger | read-only | Slot Number where the controller is physically present. Defined for EISA and MCA controller only. |
| NUM a2InterruptVectorNumber | 1.3.6.1.4.1.1608.1.1.1.2.1.23 | DmiInteger | read-only | Interrupt Vector Number being used by the controller. This value is a mapped IRQ supplied by Operating System and may not be same as the actual Interrupt Vector. |
| INT a2InterruptMode | 1.3.6.1.4.1.1608.1.1.1.2.1.24 | INTEGER | read-only | Interrupt Mode - Edge/Level. |
| NUM a2NumberOfPhysicalDevices | 1.3.6.1.4.1.1608.1.1.1.2.1.25 | DmiInteger | read-only | Number Of Physical Devices detected on this controller. |
| NUM a2NumberOfPhysicalDevicesOffline | 1.3.6.1.4.1.1608.1.1.1.2.1.26 | DmiInteger | read-only | Number of Physical Devices, whose operational state is Offline. |
| NUM a2NumberOfLogicalDevices | 1.3.6.1.4.1.1608.1.1.1.2.1.27 | DmiInteger | read-only | Number of Logical Devices currently configured. |
| NUM a2NumberOfLogicalDevicesCritical | 1.3.6.1.4.1.1608.1.1.1.2.1.28 | DmiInteger | read-only | Number of Logical Devices, whose operational state is Critical. |
| NUM a2NumberOfLogicalDevicesOffline | 1.3.6.1.4.1.1608.1.1.1.2.1.29 | DmiInteger | read-only | Number of Logical Devices, whose operational state is Offline. |
| INT a2FaultManagementType | 1.3.6.1.4.1.1608.1.1.1.2.1.30 | INTEGER | read-only | Controller Fault Management Type. |
| STR a2ArrayInformation | 1.3.6.1.4.1.1608.1.1.1.2.1.31 | DmiDisplaystring | read-only | Information about Array(s) definition. The information is provided in Channel-Target combination form. |
| NUM a2LogicalDriveReadRequests | 1.3.6.1.4.1.1608.1.1.1.2.1.32 | DmiCounter | read-only | Number of Read Requests to Logical Drives. |
| NUM a2DataReadFromLogicalDrivesInMb | 1.3.6.1.4.1.1608.1.1.1.2.1.33 | DmiInteger | read-only | Amount of Data Read from all Logical Drives - in MB. |
| NUM a2LogicalDriveWriteRequests | 1.3.6.1.4.1.1608.1.1.1.2.1.34 | DmiCounter | read-only | Number of Write Requests to Logical Drives. |
| NUM a2DataWrittenToLogicalDrivesInMb | 1.3.6.1.4.1.1608.1.1.1.2.1.35 | DmiInteger | read-only | Amount of data written to all Logical Drives - in MB. |
| NUM a2LogicalDrivesReadCacheHitPercentage | 1.3.6.1.4.1.1608.1.1.1.2.1.36 | DmiInteger | read-only | Logical Drives Read Data Cache Hit Rate. |
| NUM a2PhysicalDriveReadRequests | 1.3.6.1.4.1.1608.1.1.1.2.1.37 | DmiCounter | read-only | Number of Read Requests to all physical drives. |
| NUM a2DataReadFromPhysicalDrivesInMb | 1.3.6.1.4.1.1608.1.1.1.2.1.38 | DmiInteger | read-only | Amount of Data Read from all physical drives - in MB. |
| NUM a2PhysicalDriveWriteRequests | 1.3.6.1.4.1.1608.1.1.1.2.1.39 | DmiCounter | read-only | Number of Write Requests to all physical drives on this controll r. |
| NUM a2DataWrittenToPhysicalDrivesInMb | 1.3.6.1.4.1.1608.1.1.1.2.1.40 | DmiInteger | read-only | Amount of data written all physical drives on this controller- in MB. |
| INT a2StorageworksCabinetStatusOnChannel0 | 1.3.6.1.4.1.1608.1.1.1.2.1.41 | INTEGER | read-only | StorageWorks Cabinet Status on Channel 0 |
| INT a2StorageworksCabinetStatusOnChannel1 | 1.3.6.1.4.1.1608.1.1.1.2.1.42 | INTEGER | read-only | StorageWorks Cabinet Status on Channel 1 |
| INT a2StorageworksCabinetStatusOnChannel2 | 1.3.6.1.4.1.1608.1.1.1.2.1.43 | INTEGER | read-only | StorageWorks Cabinet Status on Channel 2 |
| INT a2BatteryBackupUnitStatus | 1.3.6.1.4.1.1608.1.1.1.2.1.44 | INTEGER | read-only | Battery Backup Unit Status. |
| NUM a2PartnerControllerNumber | 1.3.6.1.4.1.1608.1.1.1.2.1.45 | DmiInteger | read-only | Controller Number of the Partner Controller. |
| STR a2WwName | 1.3.6.1.4.1.1608.1.1.1.2.1.46 | DmiDisplaystring | read-only | Controller World Wide Name. |
| NUM a2HostControllerNumber | 1.3.6.1.4.1.1608.1.1.1.2.1.47 | DmiInteger | read-only | Host Controller Number. |
| NUM a2HostChannelNumber | 1.3.6.1.4.1.1608.1.1.1.2.1.48 | DmiInteger | read-only | Host Channel Number. |
| NUM a2HostTargetId | 1.3.6.1.4.1.1608.1.1.1.2.1.49 | DmiInteger | read-only | Host Target ID. |
| tLogicalDriveInformation | 1.3.6.1.4.1.1608.1.1.1.3 | not-accessible | Provides information about Logical Drive Configuration. | |
| eLogicalDriveInformation | 1.3.6.1.4.1.1608.1.1.1.3.1 | not-accessible | ||
| NUM a3ControllerNumber | 1.3.6.1.4.1.1608.1.1.1.3.1.1 | DmiInteger | read-only | Controller Number - used as a key. |
| NUM a3LogicalDriveNumber | 1.3.6.1.4.1.1608.1.1.1.3.1.2 | DmiInteger | read-only | Logical Drive Number - used as a Key. |
| INT a3OperationalState | 1.3.6.1.4.1.1608.1.1.1.3.1.3 | INTEGER | read-only | Logical Drive Operational State. |
| NUM a3RaidLevel | 1.3.6.1.4.1.1608.1.1.1.3.1.4 | DmiInteger | read-only | RAID Level associated with Logical Drive. |
| INT a3WritePolicy | 1.3.6.1.4.1.1608.1.1.1.3.1.5 | INTEGER | read-only | Write Cache Policy associated with Logical Drive. |
| NUM a3SizeInMb | 1.3.6.1.4.1.1608.1.1.1.3.1.6 | DmiInteger | read-only | Logical Drive Size - in MB. |
| NUM a3PhysicalSizeInMb | 1.3.6.1.4.1.1608.1.1.1.3.1.7 | DmiInteger | read-only | Total physical capacity used by this Logical Drive - in MB. |
| NUM a3StripeSizeInBytes | 1.3.6.1.4.1.1608.1.1.1.3.1.8 | DmiInteger | read-only | Stripe size associated with Logical Drive. Valid for RAID Levels 0, 5 and 6 only. Value is specifed in bytes. |
| STR a3PhysicalDriveMap | 1.3.6.1.4.1.1608.1.1.1.3.1.9 | DmiDisplaystring | read-only | List of all physical drives that make up this Logical Drive. The information is provided in Channel-Target combination form. |
| STR a3ArrayList | 1.3.6.1.4.1.1608.1.1.1.3.1.10 | DmiDisplaystring | read-only | List of Arrays, this logical drive spans across. |
| STR a3RaidLevelString | 1.3.6.1.4.1.1608.1.1.1.3.1.11 | DmiDisplaystring | read-only | Raid Level String. |
| tPhysicalDeviceInformation | 1.3.6.1.4.1.1608.1.1.1.4 | not-accessible | SCSI Physical Device Information. | |
| ePhysicalDeviceInformation | 1.3.6.1.4.1.1608.1.1.1.4.1 | not-accessible | ||
| NUM a4ControllerNumber | 1.3.6.1.4.1.1608.1.1.1.4.1.1 | DmiInteger | read-only | Controller Number - used as a key |
| NUM a4ChannelNumber | 1.3.6.1.4.1.1608.1.1.1.4.1.2 | DmiInteger | read-only | Channel Number - used as a key |
| NUM a4TargetId | 1.3.6.1.4.1.1608.1.1.1.4.1.3 | DmiInteger | read-only | Physical Device Target Id - used as a key |
| NUM a4Lun | 1.3.6.1.4.1.1608.1.1.1.4.1.4 | DmiInteger | read-only | LUN of the Physical Device. |
| INT a4OperationalState | 1.3.6.1.4.1.1608.1.1.1.4.1.5 | INTEGER | read-only | Physical Device State. |
| STR a4VendorId | 1.3.6.1.4.1.1608.1.1.1.4.1.6 | DmiDisplaystring | read-only | Physical Device Vendor Id. |
| STR a4ProductId | 1.3.6.1.4.1.1608.1.1.1.4.1.7 | DmiDisplaystring | read-only | Physical Device Product Id. |
| STR a4ProductRevisionLevel | 1.3.6.1.4.1.1608.1.1.1.4.1.8 | DmiDisplaystring | read-only | Physical Device Product Revision Level. |
| NUM a4SizeInMb | 1.3.6.1.4.1.1608.1.1.1.4.1.9 | DmiInteger | read-only | Physcical Capacity in MB, valid for physical drive only. |
| INT a4DeviceType | 1.3.6.1.4.1.1608.1.1.1.4.1.10 | INTEGER | read-only | Device Type. |
| NUM a4SoftErrors | 1.3.6.1.4.1.1608.1.1.1.4.1.11 | DmiCounter | read-only | Number of Soft Errors, valid for physical drive only. |
| NUM a4HardErrors | 1.3.6.1.4.1.1608.1.1.1.4.1.12 | DmiCounter | read-only | Number of Hard Errors, valid for physical drive only. |
| NUM a4ParityErrors | 1.3.6.1.4.1.1608.1.1.1.4.1.13 | DmiCounter | read-only | Number of Parity Errors, valid for physical drive only. |
| NUM a4MiscErrors | 1.3.6.1.4.1.1608.1.1.1.4.1.14 | DmiCounter | read-only | Number of Misc Errors, valid for physical drive only. |
| STR a4ArrayList | 1.3.6.1.4.1.1608.1.1.1.4.1.15 | DmiDisplaystring | read-only | List Of Arrays of which this physical drive is part, if applicab e. |
| STR a4LogicalDriveList | 1.3.6.1.4.1.1608.1.1.1.4.1.16 | DmiDisplaystring | read-only | List of Logical Drives that depend on this physical drive, if applicable. |
| STR a4BusSpeed | 1.3.6.1.4.1.1608.1.1.1.4.1.17 | DmiDisplaystring | read-only | Bus Transfer Speed |
| STR a4BusWidth | 1.3.6.1.4.1.1608.1.1.1.4.1.18 | DmiDisplaystring | read-only | Bus Width |
| INT a4CommandQueuing | 1.3.6.1.4.1.1608.1.1.1.4.1.19 | INTEGER | read-only | Command Tagged Queuing Enabled |
| NUM a4PfaErrors | 1.3.6.1.4.1.1608.1.1.1.4.1.20 | DmiCounter | read-only | SMART PFA Error Count, valid for physical drive only. |
| tMylexDacManagementSoftware | 1.3.6.1.4.1.1608.1.1.1.5 | |||
| eMylexDacManagementSoftware | 1.3.6.1.4.1.1608.1.1.1.5.1 | |||
| STR a5ManagementSoftwareRevision | 1.3.6.1.4.1.1608.1.1.1.5.1.1 | DmiDisplaystring | read-only | Mylex DAC Management Software Revision Information. |
| STR a5ManagementSoftwareBuildDate | 1.3.6.1.4.1.1608.1.1.1.5.1.2 | DmiDisplaystring | read-only | Mylex DAC Management Software Build Date Information - month/dat /year format. |
| STR a5MylexDacDeviceDriverRevision | 1.3.6.1.4.1.1608.1.1.1.5.1.3 | DmiDisplaystring | read-only | Mylex DAC Device driver Revision Information. |
| STR a5MylexDacDeviceDriverBuildDate | 1.3.6.1.4.1.1608.1.1.1.5.1.4 | DmiDisplaystring | read-only | Mylex DAC Device Driver Build Date Information - month/date/year format. |
| STR a5GamDriverRevision | 1.3.6.1.4.1.1608.1.1.1.5.1.5 | DmiDisplaystring | read-only | Mylex GAM Driver Revision Information. |
| STR a5GamDriverBuildDate | 1.3.6.1.4.1.1608.1.1.1.5.1.6 | DmiDisplaystring | read-only | Mylex GAM Driver Build Date Information - date/month/year format. |
| tLogicalDriveStatistics | 1.3.6.1.4.1.1608.1.1.1.6 | not-accessible | Logical Drive Performance Statistics | |
| eLogicalDriveStatistics | 1.3.6.1.4.1.1608.1.1.1.6.1 | not-accessible | ||
| NUM a6ControllerNumber | 1.3.6.1.4.1.1608.1.1.1.6.1.1 | DmiInteger | read-only | Controller Number - used as a key. |
| NUM a6LogicalDriveNumber | 1.3.6.1.4.1.1608.1.1.1.6.1.2 | DmiInteger | read-only | Logical Drive Number - used as a key. |
| NUM a6ReadRequests | 1.3.6.1.4.1.1608.1.1.1.6.1.3 | DmiCounter | read-only | Number of Read Requests. |
| NUM a6DataReadInMb | 1.3.6.1.4.1.1608.1.1.1.6.1.4 | DmiInteger | read-only | Amount of Data Read from this logical drive - in MB. |
| NUM a6WriteRequests | 1.3.6.1.4.1.1608.1.1.1.6.1.5 | DmiCounter | read-only | Number of Write Requests. |
| NUM a6DataWrittenInMb | 1.3.6.1.4.1.1608.1.1.1.6.1.6 | DmiInteger | read-only | Amount of data written - in MB. |
| NUM a6ReadCacheHitPercentage | 1.3.6.1.4.1.1608.1.1.1.6.1.7 | DmiInteger | read-only | Read Cache Hit Rate. |
| tPhysicalDriveStatistics | 1.3.6.1.4.1.1608.1.1.1.7 | not-accessible | Physical Drive Performance Statistics | |
| ePhysicalDriveStatistics | 1.3.6.1.4.1.1608.1.1.1.7.1 | not-accessible | ||
| NUM a7ControllerNumber | 1.3.6.1.4.1.1608.1.1.1.7.1.1 | DmiInteger | read-only | Controller Number - used as a key. |
| NUM a7ChannelNumber | 1.3.6.1.4.1.1608.1.1.1.7.1.2 | DmiInteger | read-only | Channel Number - used as a key. |
| NUM a7TargetId | 1.3.6.1.4.1.1608.1.1.1.7.1.3 | DmiInteger | read-only | Physical Device Target Id - used as a key. |
| NUM a7Lun | 1.3.6.1.4.1.1608.1.1.1.7.1.4 | DmiInteger | read-only | LUN of the Physical Device. |
| NUM a7ReadRequests | 1.3.6.1.4.1.1608.1.1.1.7.1.5 | DmiCounter | read-only | Number of Read Requests. |
| NUM a7DataReadInMb | 1.3.6.1.4.1.1608.1.1.1.7.1.6 | DmiInteger | read-only | Amount of Data Read - in MB. |
| NUM a7WriteRequests | 1.3.6.1.4.1.1608.1.1.1.7.1.7 | DmiCounter | read-only | Number of Write Requests. |
| NUM a7DataWrittenInMb | 1.3.6.1.4.1.1608.1.1.1.7.1.8 | DmiInteger | read-only | Amount of data written - in MB. |
| tFaultManagementCabinetInformation | 1.3.6.1.4.1.1608.1.1.1.8 | not-accessible | Fault Management Cabinet Information. | |
| eFaultManagementCabinetInformation | 1.3.6.1.4.1.1608.1.1.1.8.1 | not-accessible | ||
| NUM a8ControllerNumber | 1.3.6.1.4.1.1608.1.1.1.8.1.1 | DmiInteger | read-only | Controller Number - used as a key. |
| NUM a8ChannelNumber | 1.3.6.1.4.1.1608.1.1.1.8.1.2 | DmiInteger | read-only | Channel Number of the Channel to which the Cabinet is connected - used as a key. |
| NUM a8CabinetNumber | 1.3.6.1.4.1.1608.1.1.1.8.1.3 | DmiInteger | read-only | Cabinet Number - used as a key. |
| NUM a8TargetId | 1.3.6.1.4.1.1608.1.1.1.8.1.4 | DmiInteger | read-only | Target Id of the Cabinet. |
| NUM a8Lun | 1.3.6.1.4.1.1608.1.1.1.8.1.5 | DmiInteger | read-only | LUN of the Cabinet. |
| INT a8CabinetType | 1.3.6.1.4.1.1608.1.1.1.8.1.6 | INTEGER | read-only | Fault Management Cabinet Type, such as Conner CR6, Conner Smart and SAFTE etc. |
| NUM a8NumberOfFans | 1.3.6.1.4.1.1608.1.1.1.8.1.7 | DmiInteger | read-only | Number of Fans in the cabinet. |
| NUM a8NumberOfPowerSupplyUnits | 1.3.6.1.4.1.1608.1.1.1.8.1.8 | DmiInteger | read-only | Number of Power Supply Units in the cabinet. |
| NUM a8NumberOfHeatSensors | 1.3.6.1.4.1.1608.1.1.1.8.1.9 | DmiInteger | read-only | Number of Heat Sensors in the cabinet. |
| NUM a8NumberOfDriveSlots | 1.3.6.1.4.1.1608.1.1.1.8.1.10 | DmiInteger | read-only | Number of Drive Slots in the cabinet. |
| NUM a8NumberOfDoorLocks | 1.3.6.1.4.1.1608.1.1.1.8.1.11 | DmiInteger | read-only | Number of Door Locks in the cabinet. |
| NUM a8NumberOfSpeakers | 1.3.6.1.4.1.1608.1.1.1.8.1.12 | DmiInteger | read-only | Number of Speakers in the cabinet. |
| NUM a8NumberOfFansCritical | 1.3.6.1.4.1.1608.1.1.1.8.1.13 | DmiInteger | read-only | Number of Fans in Critical State in the cabinet. |
| NUM a8NumberOfPowerSupplyUnitsCritical | 1.3.6.1.4.1.1608.1.1.1.8.1.14 | DmiInteger | read-only | Number of Power Supply Units in Critical state in the cabinet. |
| NUM a8NumberOfHeatSensorsCritical | 1.3.6.1.4.1.1608.1.1.1.8.1.15 | DmiInteger | read-only | Number of Heat Sensors in Critical state in the cabinet. |
| NUM a8NumberOfFansFailed | 1.3.6.1.4.1.1608.1.1.1.8.1.16 | DmiInteger | read-only | Number of Fans in Failed State in the cabinet. |
| NUM a8NumberOfPowerSupplyUnitsFailed | 1.3.6.1.4.1.1608.1.1.1.8.1.17 | DmiInteger | read-only | Number of Power Supply Units in Failed state in the cabinet. |
| NUM a8NumberOfHeatSensorsFailed | 1.3.6.1.4.1.1608.1.1.1.8.1.18 | DmiInteger | read-only | Number of Heat Sensors in Failed state in the cabinet. |
| tMylexRaidEventInformation | 1.3.6.1.4.1.1608.1.1.1.9 | not-accessible | Event Information for Mylex RAID events. | |
| eMylexRaidEventInformation | 1.3.6.1.4.1.1608.1.1.1.9.1 | not-accessible | ||
| NTF physdevOnline | 1.3.6.1.4.1.1608.1.1.1.9.1.0.1 | A physical disk has been placed online. | ||
| NTF physdevHotspare | 1.3.6.1.4.1.1608.1.1.1.9.1.0.2 | A physical disk has been added as hot spare. | ||
| NTF physdevHardError | 1.3.6.1.4.1.1608.1.1.1.9.1.0.3 | Physical disk error found. | ||
| NTF physdevPfa | 1.3.6.1.4.1.1608.1.1.1.9.1.0.4 | Physical disk PFA condition found; this disk may fail soon. | ||
| NTF physdevAutoRebuildStart | 1.3.6.1.4.1.1608.1.1.1.9.1.0.5 | An automatic rebuild has started. | ||
| NTF physdevManualRebuildStart | 1.3.6.1.4.1.1608.1.1.1.9.1.0.6 | A rebuild has started. | ||
| NTF physdevRebuildDone | 1.3.6.1.4.1.1608.1.1.1.9.1.0.7 | Rebuild is over. | ||
| NTF physdevRebuildCanceled | 1.3.6.1.4.1.1608.1.1.1.9.1.0.8 | Rebuild is cancelled. | ||
| NTF physdevRebuildError | 1.3.6.1.4.1.1608.1.1.1.9.1.0.9 | Rebuild stopped with error. | ||
| NTF physdevRebuildNewdevFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.10 | Rebuild stopped with error. New physical disk failed. | ||
| NTF physdevRebuildSysdevFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.11 | Rebuild stopped because logical drive failed. | ||
| NTF physdevDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.12 | A physical disk has failed. | ||
| NTF physdevFound | 1.3.6.1.4.1.1608.1.1.1.9.1.0.13 | A new physical disk has been found. | ||
| NTF physdevGone | 1.3.6.1.4.1.1608.1.1.1.9.1.0.14 | A physical disk has been removed. | ||
| NTF physdevUnconfigured | 1.3.6.1.4.1.1608.1.1.1.9.1.0.15 | A previously configured physical disk is now available. | ||
| NTF physdevExpandcapacityStart | 1.3.6.1.4.1.1608.1.1.1.9.1.0.16 | Expand Capacity Started. | ||
| NTF physdevExpandcapacityDone | 1.3.6.1.4.1.1608.1.1.1.9.1.0.17 | Expand Capacity Completed. | ||
| NTF physdevExpandcapacityError | 1.3.6.1.4.1.1608.1.1.1.9.1.0.18 | Expand Capacity Stopped with error. | ||
| NTF physdevCommandTimeout | 1.3.6.1.4.1.1608.1.1.1.9.1.0.19 | SCSI command timeout on physical device. | ||
| NTF physdevCommandAbort | 1.3.6.1.4.1.1608.1.1.1.9.1.0.20 | SCSI command abort on physical disk. | ||
| NTF physdevCommandRetried | 1.3.6.1.4.1.1608.1.1.1.9.1.0.21 | SCSI command retried on physical disk. | ||
| NTF physdevParityError | 1.3.6.1.4.1.1608.1.1.1.9.1.0.22 | Parity error found. | ||
| NTF physdevSoftError | 1.3.6.1.4.1.1608.1.1.1.9.1.0.23 | Soft error found. | ||
| NTF physdevMiscError | 1.3.6.1.4.1.1608.1.1.1.9.1.0.24 | Misc error found. | ||
| NTF physdevReset | 1.3.6.1.4.1.1608.1.1.1.9.1.0.25 | SCSI device reset. | ||
| NTF physdevActivespare | 1.3.6.1.4.1.1608.1.1.1.9.1.0.26 | Active spare found. | ||
| NTF physdevWarmspare | 1.3.6.1.4.1.1608.1.1.1.9.1.0.27 | Warm spare found. | ||
| NTF physdevReqsense | 1.3.6.1.4.1.1608.1.1.1.9.1.0.28 | Request Sense Data available. | ||
| NTF physdevInitStarted | 1.3.6.1.4.1.1608.1.1.1.9.1.0.29 | Initialization started. | ||
| NTF physdevInitDone | 1.3.6.1.4.1.1608.1.1.1.9.1.0.30 | Initialization completed. | ||
| NTF physdevInitFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.31 | Initialization failed. | ||
| NTF physdevInitCanceled | 1.3.6.1.4.1.1608.1.1.1.9.1.0.32 | Initialization canceled. | ||
| NTF physdevWriterecDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.33 | A physical disk failed because write recovery failed. | ||
| NTF physdevResetDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.34 | A physical disk failed because SCSI bus reset failed. | ||
| NTF physdevDblccDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.35 | A physical disk failed because double check condition occured. | ||
| NTF physdevRemovedDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.36 | A physical disk failed because device is missing. | ||
| NTF physdevGrosserrDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.37 | A physical disk failed because of gross error on SCSI processor. | ||
| NTF physdevBadtagDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.38 | A physical disk failed because of invalid tag. | ||
| NTF physdevScsitmoDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.39 | A physical disk failed because a command timed out. | ||
| NTF physdevSysresetDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.40 | A physical disk failed because of the system reset. | ||
| NTF physdevBsyparDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.41 | A physical disk failed because of busy status or parity error. | ||
| NTF physdevBycmdDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.42 | A physical disk set to failed state by host. | ||
| NTF physdevSeltmoDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.43 | A physical disk failed because access to the device met with a selection time out. | ||
| NTF physdevSeqerrDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.44 | A physical disk failed because of a sequence error in the SCSI bus phase handling. | ||
| NTF physdevUnknownstsDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.45 | A physical disk failed because device returned an unknown status. | ||
| NTF physdevNotrdyDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.46 | A physical disk failed because device is not ready. | ||
| NTF physdevMissingDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.47 | A physical disk failed because device was not found on start up. | ||
| NTF physdevCodwrfailDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.48 | A physical disk failed because write operation of the 'Configuration On Disk' failed. | ||
| NTF physdevBdtwrfailDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.49 | A physical disk failed because write operation of 'Bad Data Table' failed. | ||
| NTF physdevOffline | 1.3.6.1.4.1.1608.1.1.1.9.1.0.50 | Physical disk status changed to offline. | ||
| NTF physdevStandby | 1.3.6.1.4.1.1608.1.1.1.9.1.0.51 | Physical disk status changed to hot spare. | ||
| NTF physdevRebuild | 1.3.6.1.4.1.1608.1.1.1.9.1.0.52 | Physical disk status changed to rebuild. | ||
| NTF physdevIdMismatch | 1.3.6.1.4.1.1608.1.1.1.9.1.0.53 | Physical device ID did not match. | ||
| NTF physdevFailedStart | 1.3.6.1.4.1.1608.1.1.1.9.1.0.54 | Physical disk failed to start. | ||
| NTF physdevOffsetSet | 1.3.6.1.4.1.1608.1.1.1.9.1.0.55 | Physical disk negotiated different offset than config. | ||
| NTF physdevSetBusWidth | 1.3.6.1.4.1.1608.1.1.1.9.1.0.56 | Physical disk negotiated different bus width than config. | ||
| NTF physdevMissingOnstartup | 1.3.6.1.4.1.1608.1.1.1.9.1.0.57 | Physical disk missing on startup. | ||
| NTF physdevRebuildStartFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.58 | Rebuild startup failed due to lower physical disk capacity. | ||
| NTF physdevMovingToOtherChn | 1.3.6.1.4.1.1608.1.1.1.9.1.0.59 | Physical disk is switching from one channel to the other channel. | ||
| NTF physdevOfflineDeviceMadeOnline | 1.3.6.1.4.1.1608.1.1.1.9.1.0.60 | Temporary-Dead physical disk is automatically made online. | ||
| NTF physdevStandbyRebuildStart | 1.3.6.1.4.1.1608.1.1.1.9.1.0.61 | A standby rebuild has started. | ||
| NTF physdevHotSpareSmaller | 1.3.6.1.4.1.1608.1.1.1.9.1.0.62 | Hot spare replaced with a smaller capacity physical disk. | ||
| NTF ppilotLogicalDiskOnline | 1.3.6.1.4.1.1608.1.1.1.9.1.0.63 | A storage access path has come online. | ||
| NTF ppilotLogicalDiskOffline | 1.3.6.1.4.1.1608.1.1.1.9.1.0.64 | A storage access path has been lost. | ||
| NTF ppilotLogicalDiskPathFailover | 1.3.6.1.4.1.1608.1.1.1.9.1.0.65 | A storage access path has shifted to the alternate path. | ||
| NTF ppilotLogicalDiskPathFailback | 1.3.6.1.4.1.1608.1.1.1.9.1.0.66 | A storage access path has shifted to the primary path. | ||
| NTF physdevNonRedundantAccess | 1.3.6.1.4.1.1608.1.1.1.9.1.0.67 | Physical Disk found on only one disk channel. | ||
| NTF physdevTypeInvalid | 1.3.6.1.4.1.1608.1.1.1.9.1.0.68 | Physical disk type is not approved by vendor. | ||
| NTF physdevSoftId | 1.3.6.1.4.1.1608.1.1.1.9.1.0.69 | Physical disk has acquired an inappropriate loop ID. Enclosure disk-slot operations are disabled while this condition persists. | ||
| NTF physdevPortFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.70 | Physical disk port has failed or cannot operate at the configured channel speed. | ||
| NTF ctldevMirrorRaceEntryFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.71 | Mirror Race recovery failed for logical drive. | ||
| NTF ctldevCtrlParamsChecksumFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.72 | Controller parameters checksum verification failed -- restored default. | ||
| NTF firmwareUpgradeStarted | 1.3.6.1.4.1.1608.1.1.1.9.1.0.73 | Online controller firmware upgrade has started. | ||
| NTF firmwareUpgradeComplete | 1.3.6.1.4.1.1608.1.1.1.9.1.0.74 | Online firmware upgrade has completed successfully. | ||
| NTF firmwareUpgradeFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.75 | Online firmware upgrade has failed. | ||
| NTF fibredevLoopidSoftaddrOccurred | 1.3.6.1.4.1.1608.1.1.1.9.1.0.96 | Device loop ID conflict (soft addressing) detected. | ||
| NTF sysdevCheckStart | 1.3.6.1.4.1.1608.1.1.1.9.1.0.128 | Consistency check is started. | ||
| NTF sysdevCheckDone | 1.3.6.1.4.1.1608.1.1.1.9.1.0.129 | Consistency check is finished. | ||
| NTF sysdevCheckCanceled | 1.3.6.1.4.1.1608.1.1.1.9.1.0.130 | Consistency check is cancelled. | ||
| NTF sysdevCheckError | 1.3.6.1.4.1.1608.1.1.1.9.1.0.131 | Consistency check on logical drive error. | ||
| NTF sysdevCheckSysdevFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.132 | Consistency check on logical drive failed. | ||
| NTF sysdevCheckPhysdevFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.133 | Consistency check failed due to physical disk failure. | ||
| NTF sysdevOffline | 1.3.6.1.4.1.1608.1.1.1.9.1.0.134 | Logical drive has been made offline. | ||
| NTF sysdevCritical | 1.3.6.1.4.1.1608.1.1.1.9.1.0.135 | Logical drive is critical. | ||
| NTF sysdevOnline | 1.3.6.1.4.1.1608.1.1.1.9.1.0.136 | Logical drive has been placed online. | ||
| NTF sysdevAutoRebuildStart | 1.3.6.1.4.1.1608.1.1.1.9.1.0.137 | An automatic rebuild has started on logical drive. | ||
| NTF sysdevManualRebuildStart | 1.3.6.1.4.1.1608.1.1.1.9.1.0.138 | A manual rebuild has started on logical drive. | ||
| NTF sysdevRebuildDone | 1.3.6.1.4.1.1608.1.1.1.9.1.0.139 | Rebuild on logical drive is over. | ||
| NTF sysdevRebuildCanceled | 1.3.6.1.4.1.1608.1.1.1.9.1.0.140 | Rebuild on logical drive is cancelled. | ||
| NTF sysdevRebuildError | 1.3.6.1.4.1.1608.1.1.1.9.1.0.141 | Rebuild stopped with error. | ||
| NTF sysdevRebuildNewdevFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.142 | Rebuild stopped with error. New physical disk failed. | ||
| NTF sysdevRebuildSysdevFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.143 | Rebuild stopped because logical drive failed. | ||
| NTF sysdevInitStarted | 1.3.6.1.4.1.1608.1.1.1.9.1.0.144 | Logical drive initialization started. | ||
| NTF sysdevInitDone | 1.3.6.1.4.1.1608.1.1.1.9.1.0.145 | Logical drive initialization done. | ||
| NTF sysdevInitCanceled | 1.3.6.1.4.1.1608.1.1.1.9.1.0.146 | Logical drive initialization cancelled. | ||
| NTF sysdevInitFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.147 | Logical drive initialization failed. | ||
| NTF sysdevFound | 1.3.6.1.4.1.1608.1.1.1.9.1.0.148 | A logical drive has been found. | ||
| NTF sysdevGone | 1.3.6.1.4.1.1608.1.1.1.9.1.0.149 | A logical drive has been deleted. | ||
| NTF sysdevExpandcapacityStart | 1.3.6.1.4.1.1608.1.1.1.9.1.0.150 | Expand capacity started. | ||
| NTF sysdevExpandcapacityDone | 1.3.6.1.4.1.1608.1.1.1.9.1.0.151 | Expand capacity completed. | ||
| NTF sysdevExpandcapacityError | 1.3.6.1.4.1.1608.1.1.1.9.1.0.152 | Expand capacity stopped with error. | ||
| NTF sysdevBadblock | 1.3.6.1.4.1.1608.1.1.1.9.1.0.153 | Bad Blocks found. | ||
| NTF sysdevSizechanged | 1.3.6.1.4.1.1608.1.1.1.9.1.0.154 | Logical drive size changed. | ||
| NTF sysdevTypechanged | 1.3.6.1.4.1.1608.1.1.1.9.1.0.155 | Logical drive type changed. | ||
| NTF sysdevBaddatablock | 1.3.6.1.4.1.1608.1.1.1.9.1.0.156 | Bad data blocks found. Possible data loss. | ||
| NTF sysdevWrLunMap | 1.3.6.1.4.1.1608.1.1.1.9.1.0.157 | Logical drive LUN mapping has been written to config. | ||
| NTF sysdevDatareadFromBlockInBdt | 1.3.6.1.4.1.1608.1.1.1.9.1.0.158 | Attempt to read data from block that is marked in Bad Data Table. | ||
| NTF sysdevDataForBlockLost | 1.3.6.1.4.1.1608.1.1.1.9.1.0.159 | Data for Disk Block has been lost due to Logical Drive problem. | ||
| NTF sysdevOfflineDeviceMadeAvailableWithDataloss | 1.3.6.1.4.1.1608.1.1.1.9.1.0.160 | Temporary-Offline RAID5/RAID3 array is available to the user again with the possibility of data loss in the array. | ||
| NTF sysdevOfflineDeviceMadeAvailable | 1.3.6.1.4.1.1608.1.1.1.9.1.0.161 | Temporary-Offline RAID0+1/RAID1/RAID0/JBOD array is available to the user again. | ||
| NTF sysdevStandbyRebuildStart | 1.3.6.1.4.1.1608.1.1.1.9.1.0.162 | A standby rebuild has started on a logical drive. | ||
| NTF sysdevBgInitStarted | 1.3.6.1.4.1.1608.1.1.1.9.1.0.176 | Logical drive background initialization started. | ||
| NTF sysdevBgInitStopped | 1.3.6.1.4.1.1608.1.1.1.9.1.0.177 | Logical drive background initialization stopped. | ||
| NTF sysdevBgInitPaused | 1.3.6.1.4.1.1608.1.1.1.9.1.0.178 | Logical drive background initialization paused. | ||
| NTF sysdevBgInitRestarted | 1.3.6.1.4.1.1608.1.1.1.9.1.0.179 | Logical drive background initialization restarted. | ||
| NTF sysdevBgInitFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.180 | Logical drive background initialization failed. | ||
| NTF sysdevBgInitCompleted | 1.3.6.1.4.1.1608.1.1.1.9.1.0.181 | Logical drive background initialization completed. | ||
| NTF sysdevDataLossLowBbuCharge | 1.3.6.1.4.1.1608.1.1.1.9.1.0.182 | Low battery charge level. Logical drive may have lost data. | ||
| NTF fmtfanFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.256 | Fan failure. | ||
| NTF fmtfanOk | 1.3.6.1.4.1.1608.1.1.1.9.1.0.257 | Fan has been restored. | ||
| NTF aemiFanFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.258 | Fan failure. | ||
| NTF fmtfanNotpresent | 1.3.6.1.4.1.1608.1.1.1.9.1.0.259 | Storage cabinet fan is not present. | ||
| NTF fmtpowerFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.272 | Power supply failure. | ||
| NTF fmtpowerOk | 1.3.6.1.4.1.1608.1.1.1.9.1.0.273 | Power supply has been restored. | ||
| NTF aemiPwrSupplyFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.274 | Power supply failure. | ||
| NTF fmtpowerNotpresent | 1.3.6.1.4.1.1608.1.1.1.9.1.0.275 | Storage cabinet power supply is not present. | ||
| NTF fmtheatBad | 1.3.6.1.4.1.1608.1.1.1.9.1.0.288 | Over temperature. Temperature is above 70 degrees Celsius. | ||
| NTF fmtheatCritical | 1.3.6.1.4.1.1608.1.1.1.9.1.0.289 | Temperature is above 50 degrees Celsius. | ||
| NTF fmtheatOk | 1.3.6.1.4.1.1608.1.1.1.9.1.0.290 | Normal temperature has been restored. | ||
| NTF aemiOverTemperature | 1.3.6.1.4.1.1608.1.1.1.9.1.0.291 | Over temperature. | ||
| NTF fmtheatNotpresent | 1.3.6.1.4.1.1608.1.1.1.9.1.0.292 | Storage cabinet temperature sensor is not present. | ||
| NTF fmtstwkFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.304 | Storage Works enclosure reported failure state. | ||
| NTF fmtstwkCritical | 1.3.6.1.4.1.1608.1.1.1.9.1.0.305 | Storage Works enclosure reported critical state. | ||
| NTF fmtstwkOk | 1.3.6.1.4.1.1608.1.1.1.9.1.0.306 | Storage Works enclosure reported normal state. | ||
| NTF fmtUpsDisabled | 1.3.6.1.4.1.1608.1.1.1.9.1.0.307 | Uninterruptible power supply disabled. | ||
| NTF fmtUpsAcFail | 1.3.6.1.4.1.1608.1.1.1.9.1.0.308 | Uninterruptible power supply ac failed. | ||
| NTF fmtUpsBatLow | 1.3.6.1.4.1.1608.1.1.1.9.1.0.309 | Uninterruptible power supply battery low. | ||
| NTF fmtUpsFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.310 | Uninterruptible power supply failed. | ||
| NTF fmtUpsOk | 1.3.6.1.4.1.1608.1.1.1.9.1.0.311 | Uninterruptible power supply normal. | ||
| NTF enclfanFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.320 | Fan failure. | ||
| NTF enclfanOk | 1.3.6.1.4.1.1608.1.1.1.9.1.0.321 | Fan has been restored. | ||
| NTF enclfanNotpresent | 1.3.6.1.4.1.1608.1.1.1.9.1.0.322 | Fan is not present. | ||
| NTF enclpowerFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.323 | Power supply failure. | ||
| NTF enclpowerOk | 1.3.6.1.4.1.1608.1.1.1.9.1.0.324 | Power supply has been restored. | ||
| NTF enclpowerNotpresent | 1.3.6.1.4.1.1608.1.1.1.9.1.0.325 | Power supply is not present. | ||
| NTF enclheatBad | 1.3.6.1.4.1.1608.1.1.1.9.1.0.326 | Temperature is over safe limit. Failure imminent. | ||
| NTF enclheatCritical | 1.3.6.1.4.1.1608.1.1.1.9.1.0.327 | Temperature is above working limit. | ||
| NTF enclheatOk | 1.3.6.1.4.1.1608.1.1.1.9.1.0.328 | Normal temperature has been restored. | ||
| NTF enclheatNotpresent | 1.3.6.1.4.1.1608.1.1.1.9.1.0.329 | Temperature sensor is not present. | ||
| NTF enclaccessCritical | 1.3.6.1.4.1.1608.1.1.1.9.1.0.330 | Enclosure access critical. | ||
| NTF enclaccessOk | 1.3.6.1.4.1.1608.1.1.1.9.1.0.331 | Enclosure access has been restored. | ||
| NTF enclaccessOffline | 1.3.6.1.4.1.1608.1.1.1.9.1.0.332 | Enclosure access is offline. | ||
| NTF enclsesSoftaddrOccurred | 1.3.6.1.4.1.1608.1.1.1.9.1.0.333 | Enclosure soft addressing detected. | ||
| NTF enclaccessReady | 1.3.6.1.4.1.1608.1.1.1.9.1.0.334 | Enclosure services ready. | ||
| NTF enclheatUnknown | 1.3.6.1.4.1.1608.1.1.1.9.1.0.335 | Access to temperature sensor has been lost. | ||
| NTF enclpowerUnknown | 1.3.6.1.4.1.1608.1.1.1.9.1.0.336 | Access to power supply status information has been lost. | ||
| NTF enclfanUnknown | 1.3.6.1.4.1.1608.1.1.1.9.1.0.337 | Access to fan status information has been lost. | ||
| NTF enclosureShutdown | 1.3.6.1.4.1.1608.1.1.1.9.1.0.338 | Physical disks in enclosure being spundown. | ||
| NTF enclcoldWarn | 1.3.6.1.4.1.1608.1.1.1.9.1.0.339 | Temperature is below working limit. | ||
| NTF enclcoldFail | 1.3.6.1.4.1.1608.1.1.1.9.1.0.340 | Temperature is under safe limit. Failure imminent. | ||
| NTF systemStarted | 1.3.6.1.4.1.1608.1.1.1.9.1.0.384 | Array management server software started successfully. | ||
| NTF ctldevWritebackError | 1.3.6.1.4.1.1608.1.1.1.9.1.0.385 | Write back error. | ||
| NTF ctldevStateTableFull | 1.3.6.1.4.1.1608.1.1.1.9.1.0.386 | Internal log structures getting full,PLEASE SHUTDOWN AND RESET THE SYSTEM IN THE NEAR FUTURE. | ||
| NTF ctldevDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.388 | Controller is dead. System is disconnecting from this controller. | ||
| NTF ctldevReset | 1.3.6.1.4.1.1608.1.1.1.9.1.0.389 | Controller has been reset. | ||
| NTF ctldevFound | 1.3.6.1.4.1.1608.1.1.1.9.1.0.390 | Controller is found. | ||
| NTF ctldevGone | 1.3.6.1.4.1.1608.1.1.1.9.1.0.391 | Controller is gone. System is disconnecting from this controller. | ||
| NTF ctldevBbuFound | 1.3.6.1.4.1.1608.1.1.1.9.1.0.392 | Battery present. | ||
| NTF ctldevBbuPowerLow | 1.3.6.1.4.1.1608.1.1.1.9.1.0.393 | Battery power low. | ||
| NTF ctldevBbuPowerOk | 1.3.6.1.4.1.1608.1.1.1.9.1.0.394 | Battery power OK. | ||
| NTF ctldevPowerOff | 1.3.6.1.4.1.1608.1.1.1.9.1.0.395 | Controller is gone. System is disconnecting from this controller. | ||
| NTF ctldevPowerOn | 1.3.6.1.4.1.1608.1.1.1.9.1.0.396 | Controller powered on | ||
| NTF ctldevOnline | 1.3.6.1.4.1.1608.1.1.1.9.1.0.397 | Controller is online. | ||
| NTF ctldevOffline | 1.3.6.1.4.1.1608.1.1.1.9.1.0.398 | Controller is gone. System is disconnecting from this controller. | ||
| NTF ctldevCritical | 1.3.6.1.4.1.1608.1.1.1.9.1.0.399 | Controller's partner is gone, controller is in failover mode now. | ||
| NTF ctldevBbuRecondStart | 1.3.6.1.4.1.1608.1.1.1.9.1.0.400 | Battery reconditioning is started. | ||
| NTF ctldevBbuRecondDone | 1.3.6.1.4.1.1608.1.1.1.9.1.0.401 | Battery reconditioning is finished. | ||
| NTF ctldevBbuRecondAbort | 1.3.6.1.4.1.1608.1.1.1.9.1.0.402 | Battery reconditioning is canceled. | ||
| NTF ctldevInstallationAborted | 1.3.6.1.4.1.1608.1.1.1.9.1.0.403 | Installation aborted. | ||
| NTF ctldevFirmwareMismatch | 1.3.6.1.4.1.1608.1.1.1.9.1.0.404 | Controller firmware mismatch. | ||
| NTF ctldevBbuNoresponse | 1.3.6.1.4.1.1608.1.1.1.9.1.0.405 | The Battery Backup Unit is removed. | ||
| NTF ctldevWarmBootError | 1.3.6.1.4.1.1608.1.1.1.9.1.0.406 | WARM BOOT failed. | ||
| NTF ctldevBbuCalibrateStart | 1.3.6.1.4.1.1608.1.1.1.9.1.0.407 | Battery calibration cycle started. | ||
| NTF ctldevBbuCalibrateDone | 1.3.6.1.4.1.1608.1.1.1.9.1.0.408 | Battery calibration cycle finished. | ||
| NTF ctldevBbuCalibrateAbort | 1.3.6.1.4.1.1608.1.1.1.9.1.0.409 | Battery calibration cycle was cancelled. | ||
| NTF ctldevBbuNoBattery | 1.3.6.1.4.1.1608.1.1.1.9.1.0.410 | Battery is not present. | ||
| NTF ctldevConservCacheMode | 1.3.6.1.4.1.1608.1.1.1.9.1.0.411 | Controller entered conservative cache mode. | ||
| NTF ctldevNormalCacheMode | 1.3.6.1.4.1.1608.1.1.1.9.1.0.412 | Controller entered normal cache mode. | ||
| NTF ctldevDevStartCmplt | 1.3.6.1.4.1.1608.1.1.1.9.1.0.413 | Controller device start complete. | ||
| NTF ctldevSoftEccCorrected | 1.3.6.1.4.1.1608.1.1.1.9.1.0.414 | Soft ECC error corrected. | ||
| NTF ctldevHardEccCorrected | 1.3.6.1.4.1.1608.1.1.1.9.1.0.415 | Hard ECC error corrected. | ||
| NTF ctldevBbuRecondNeeded | 1.3.6.1.4.1.1608.1.1.1.9.1.0.416 | Battery recondition suggested. | ||
| NTF ctldevRemovedPtnr | 1.3.6.1.4.1.1608.1.1.1.9.1.0.417 | Controller's partner has been removed. | ||
| NTF ctldevBbuOutOfService | 1.3.6.1.4.1.1608.1.1.1.9.1.0.418 | BBU out of service. | ||
| NTF ctldevUpdatePtnrStatus | 1.3.6.1.4.1.1608.1.1.1.9.1.0.419 | Updated partner's status. | ||
| NTF ctldevRelinquishPtnr | 1.3.6.1.4.1.1608.1.1.1.9.1.0.420 | Relinquished partner. | ||
| NTF ctldevInsertedPtnr | 1.3.6.1.4.1.1608.1.1.1.9.1.0.421 | Inserted partner. | ||
| NTF ctldevDualEnabled | 1.3.6.1.4.1.1608.1.1.1.9.1.0.422 | Dual controllers enabled. | ||
| NTF ctldevKillPtnr | 1.3.6.1.4.1.1608.1.1.1.9.1.0.423 | Disabled partner. | ||
| NTF ctldevNexus | 1.3.6.1.4.1.1608.1.1.1.9.1.0.424 | Dual controllers entered nexus. | ||
| NTF ctldevBadBootromImage | 1.3.6.1.4.1.1608.1.1.1.9.1.0.425 | Controller boot ROM image needs to be reloaded. | ||
| NTF ctldevBadMacAddress | 1.3.6.1.4.1.1608.1.1.1.9.1.0.426 | Controller is using default non-unique world-wide name. | ||
| NTF ctldevMirrorRaceRecoveryFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.427 | Mirror Race recovery failed. | ||
| NTF ctldevMirrorCriticalDrive | 1.3.6.1.4.1.1608.1.1.1.9.1.0.428 | Mirror Race on critical logical drive. | ||
| NTF ctldevInCluster | 1.3.6.1.4.1.1608.1.1.1.9.1.0.429 | Controller connected to cluster. | ||
| NTF ctldevNotInCluster | 1.3.6.1.4.1.1608.1.1.1.9.1.0.430 | Controller disconnected from cluster. | ||
| NTF sysdevDataLossImproperShutdown | 1.3.6.1.4.1.1608.1.1.1.9.1.0.431 | Controller improperly shutdown! Data may have been lost. | ||
| NTF ctldevAutomaticFlashStarted | 1.3.6.1.4.1.1608.1.1.1.9.1.0.432 | Dual-active automatic flash of replacement controller. | ||
| NTF ctldevNegotiationFailedJumpers | 1.3.6.1.4.1.1608.1.1.1.9.1.0.433 | Dual-active negotiation failed jumpers. | ||
| NTF ctldevNegotiationSameId | 1.3.6.1.4.1.1608.1.1.1.9.1.0.434 | Dual-active negotiation failed IDs. | ||
| NTF ctldevNegotiationBoardType | 1.3.6.1.4.1.1608.1.1.1.9.1.0.435 | Dual-active negotiation failed board types. | ||
| NTF ctldevNegotiationDiskChannels | 1.3.6.1.4.1.1608.1.1.1.9.1.0.436 | Dual-active negotiation failed disk channels. | ||
| NTF ctldevNegotiationHostChannels | 1.3.6.1.4.1.1608.1.1.1.9.1.0.437 | Dual-active negotiation failed host ports. | ||
| NTF ctldevNegotiationMemorySize | 1.3.6.1.4.1.1608.1.1.1.9.1.0.438 | Dual-active negotiation failed memory size. | ||
| NTF ctldevNegotiationCacheSize | 1.3.6.1.4.1.1608.1.1.1.9.1.0.439 | Dual-active negotiation failed cache memory size. | ||
| NTF ctldevMirrorRaceTableError | 1.3.6.1.4.1.1608.1.1.1.9.1.0.440 | Error in Mirror Race Table. | ||
| NTF ctldevStopRejected | 1.3.6.1.4.1.1608.1.1.1.9.1.0.441 | A replacement controller attempted to stop the surviving | ||
| NTF systemStartedNew | 1.3.6.1.4.1.1608.1.1.1.9.1.0.512 | System started. | ||
| NTF systemSizeTableFull | 1.3.6.1.4.1.1608.1.1.1.9.1.0.513 | Size table full. | ||
| NTF systemUserLoggedIn | 1.3.6.1.4.1.1608.1.1.1.9.1.0.514 | User logged in. | ||
| NTF systemUserLoggedOut | 1.3.6.1.4.1.1608.1.1.1.9.1.0.515 | User logged out. | ||
| NTF systemAlive | 1.3.6.1.4.1.1608.1.1.1.9.1.0.516 | Server alive. | ||
| NTF systemDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.517 | Lost connection to server, or server is down. | ||
| NTF autobootChanged | 1.3.6.1.4.1.1608.1.1.1.9.1.0.518 | Automatic reboot count has changed. | ||
| NTF ctldevBbuBattTestStart | 1.3.6.1.4.1.1608.1.1.1.9.1.0.519 | Battery test has started | ||
| NTF ctldevBbuBattTestComplete | 1.3.6.1.4.1.1608.1.1.1.9.1.0.520 | Battery test complete | ||
| NTF ctldevBbuBattTestCanceled | 1.3.6.1.4.1.1608.1.1.1.9.1.0.521 | Battery test canceled | ||
| NTF ctldevBbuBattTestFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.522 | Battery test failed - battery bad | ||
| NTF channelFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.640 | Channel Failed. | ||
| NTF channelOk | 1.3.6.1.4.1.1608.1.1.1.9.1.0.641 | Channel Online. | ||
| NTF channelScsiBusDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.642 | Back end SCSI bus dead. | ||
| NTF channelScsiBusAlive | 1.3.6.1.4.1.1608.1.1.1.9.1.0.643 | Back end SCSI bus alive. | ||
| NTF channelFiberDead | 1.3.6.1.4.1.1608.1.1.1.9.1.0.644 | Back end fibre dead. | ||
| NTF channelFiberAlive | 1.3.6.1.4.1.1608.1.1.1.9.1.0.645 | Back end fibre alive. | ||
| NTF logEmpty | 1.3.6.1.4.1.1608.1.1.1.9.1.0.700 | Event log empty. | ||
| NTF logOutSync | 1.3.6.1.4.1.1608.1.1.1.9.1.0.701 | Event log entries lost. | ||
| NTF logRequestSense | 1.3.6.1.4.1.1608.1.1.1.9.1.0.702 | Request Sense | ||
| NTF logSetRtc | 1.3.6.1.4.1.1608.1.1.1.9.1.0.703 | Set real time clock. | ||
| NTF cfgNew | 1.3.6.1.4.1.1608.1.1.1.9.1.0.800 | New configuration received. | ||
| NTF cfgClear | 1.3.6.1.4.1.1608.1.1.1.9.1.0.801 | Configuration cleared. | ||
| NTF cfgInvalid | 1.3.6.1.4.1.1608.1.1.1.9.1.0.802 | Configuration invalid. | ||
| NTF cfgCodAccessError | 1.3.6.1.4.1.1608.1.1.1.9.1.0.803 | Configuration on disk access error. | ||
| NTF cfgCodConverted | 1.3.6.1.4.1.1608.1.1.1.9.1.0.804 | Configuration on disk converted. | ||
| NTF cfgCodImportFailed | 1.3.6.1.4.1.1608.1.1.1.9.1.0.805 | Configuration on disk import failed. | ||
| NTF debugDumpGenerated | 1.3.6.1.4.1.1608.1.1.1.9.1.0.806 | A debug dump exists on this system. | ||
| NTF debugDumpGeneratedPartner | 1.3.6.1.4.1.1608.1.1.1.9.1.0.807 | A debug dump exists on this system. | ||
| NTF cfgCodNotFound | 1.3.6.1.4.1.1608.1.1.1.9.1.0.808 | No valid Configuration On Disk (COD) found. | ||
| NTF cfgCodLunMapNotFound | 1.3.6.1.4.1.1608.1.1.1.9.1.0.809 | No valid SAN map found in Configuration On Disk (COD) found. | ||
| NTF fatalHang | 1.3.6.1.4.1.1608.1.1.1.9.1.0.896 | Internal controller hung. | ||
| NTF fatalBrkp | 1.3.6.1.4.1.1608.1.1.1.9.1.0.897 | Internal controller firmware breakpoint. | ||
| NTF i960HwErr | 1.3.6.1.4.1.1608.1.1.1.9.1.0.912 | Internal controller i960 processor error. | ||
| NTF sarmHwErr | 1.3.6.1.4.1.1608.1.1.1.9.1.0.928 | Internal controller Strong-ARM processor error. | ||
| NTF scsiHwErr | 1.3.6.1.4.1.1608.1.1.1.9.1.0.944 | Internal Controller Backend Hardware Error. | ||
| NUM a9EventTableIndex | 1.3.6.1.4.1.1608.1.1.1.9.1.1 | DmiInteger | read-only | Index to the event table, Used as a key. A total number of 256 events can be stored in the event table. However, the Event Table Index can be greater than 256 |
| INT a9EventCode | 1.3.6.1.4.1.1608.1.1.1.9.1.2 | INTEGER | read-only | Mylex RAID event code. |
| NUM a9EventTimeStamp | 1.3.6.1.4.1.1608.1.1.1.9.1.3 | DmiInteger | read-only | Time Stamp associated with this event. It's the number of seconds since midnight(00:00:00) January 1, 1970 GMT. |
| NUM a9ControllerNumber | 1.3.6.1.4.1.1608.1.1.1.9.1.4 | DmiInteger | read-only | Controller Number of the controller, which causes the event, if applicable |
| NUM a9ChannelNumber | 1.3.6.1.4.1.1608.1.1.1.9.1.5 | DmiInteger | read-only | Channel Number of the device, which causes the event, if applicable |
| NUM a9TargetId | 1.3.6.1.4.1.1608.1.1.1.9.1.6 | DmiInteger | read-only | Target Id of the physical device, which causes the event, if applicable |
| NUM a9Lun | 1.3.6.1.4.1.1608.1.1.1.9.1.7 | DmiInteger | read-only | LUN of the device, which causes the event, if applicable |
| NUM a9LogicalDriveNumber | 1.3.6.1.4.1.1608.1.1.1.9.1.8 | DmiInteger | read-only | Drive Number of the Logical Drive, which causes the event, if applicable |
| NUM a9FmtCabinetNumber | 1.3.6.1.4.1.1608.1.1.1.9.1.9 | DmiInteger | read-only | Fault Management Cabinet Number of the cabinet, which causes the event, if applicable |
| NUM a9FanUnitNumber | 1.3.6.1.4.1.1608.1.1.1.9.1.10 | DmiInteger | read-only | Unit Number of the fan which, causes the event, if applicable |
| NUM a9PowerSupplyUnitNumber | 1.3.6.1.4.1.1608.1.1.1.9.1.11 | DmiInteger | read-only | Unit Nubmer of the PSU which, causes the event, if applicable |
| NUM a9HeatSensorUnitNumber | 1.3.6.1.4.1.1608.1.1.1.9.1.12 | DmiInteger | read-only | Unit Number of the Heat Sensor, which causes the event, if applicable |
| NUM a9EnclosureUnitNumber | 1.3.6.1.4.1.1608.1.1.1.9.1.13 | DmiInteger | read-only | Unit Number of the Enclosure Unit, which causes the event, if applicable |
| tBatteryBackupUnitInformation | 1.3.6.1.4.1.1608.1.1.1.10 | not-accessible | This group provides Battery Backup Unit Information. | |
| eBatteryBackupUnitInformation | 1.3.6.1.4.1.1608.1.1.1.10.1 | not-accessible | ||
| NUM a10ControllerNumber | 1.3.6.1.4.1.1608.1.1.1.10.1.1 | DmiInteger | read-only | Controller Number of the controller to which this BBU is connected. |
| NUM a10OperationalState | 1.3.6.1.4.1.1608.1.1.1.10.1.2 | DmiInteger | read-only | Operational state of Battery Backup Unit. |
| INT a10BatteryType | 1.3.6.1.4.1.1608.1.1.1.10.1.3 | INTEGER | read-only | Battery Type. |
| NUM a10CurrentPowerInHours | 1.3.6.1.4.1.1608.1.1.1.10.1.4 | DmiInteger | read-only | Current Power in Hours. |
| NUM a10MaximumPowerInHours | 1.3.6.1.4.1.1608.1.1.1.10.1.5 | DmiInteger | read-only | Maximum Power in Hours. |
| NUM a10ThresholdValueInHours | 1.3.6.1.4.1.1608.1.1.1.10.1.6 | DmiInteger | read-only | Threshold Value in Hours. |
| NUM a10ChargeLevelInPercentage | 1.3.6.1.4.1.1608.1.1.1.10.1.7 | DmiInteger | read-only | Battery Charge Level (in percentage). |
| NUM a10Version | 1.3.6.1.4.1.1608.1.1.1.10.1.8 | DmiInteger | read-only | BBU Hardware Version Number. |
| STR a10OperationalStateString | 1.3.6.1.4.1.1608.1.1.1.10.1.9 | DmiDisplaystring | read-only | BBU Operational State String. |
RFC description
Mylex disk array controller management including RAID configuration, cache status, and performance metrics.
Start monitoring Server with Mylex RAID disk array controller with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.