| OID symbolic | OID numeric | Type | Access | Description |
| microsens | 1.3.6.1.4.1.3181 | | | Microsens private NOTIFICATION for Generation 6 Software Platform |
| managedSwitches | 1.3.6.1.4.1.3181.10 | | | |
| g6 | 1.3.6.1.4.1.3181.10.6 | | | |
| g6TrapGroup | 1.3.6.1.4.1.3181.10.6.1 | | | |
| g6Trap | 1.3.6.1.4.1.3181.10.6.1.1 | | | |
| NTF g6TrapDebug | 1.3.6.1.4.1.3181.10.6.1.1.3 | | | Internal Debug Messages. |
| NTF g6TrapAliveTest | 1.3.6.1.4.1.3181.10.6.1.1.4 | | | Can be used to check out event and notification system with no effect to the system operation. |
| NTF g6TrapFirmwareUpdateOk | 1.3.6.1.4.1.3181.10.6.1.1.5 | | | Firmware installation has successfully taken place. |
| NTF g6TrapFirmwareUpdateFail | 1.3.6.1.4.1.3181.10.6.1.1.6 | | | Firmware installation has FAILED. |
| NTF g6TrapLicenseViolation | 1.3.6.1.4.1.3181.10.6.1.1.7 | | | Firmware is used for which no license has been granted. Please contact sales representant. |
| NTF g6TrapColdStart | 1.3.6.1.4.1.3181.10.6.1.1.8 | | | The device has booted. Data transmission was interrupted. |
| NTF g6TrapWarmStart | 1.3.6.1.4.1.3181.10.6.1.1.9 | | | The device has (partially) booted without interupting data transmission services. |
| NTF g6TrapFactoryReset | 1.3.6.1.4.1.3181.10.6.1.1.10 | | | Configuration factory reset is executed via local push button on the device. |
| NTF g6TrapConfigurationLoaded | 1.3.6.1.4.1.3181.10.6.1.1.11 | | | All or a specific configuration file(s) has been restored and activated. |
| NTF g6TrapChangeConfig | 1.3.6.1.4.1.3181.10.6.1.1.12 | | | A configuration parameter has been modified and activated. |
| NTF g6TrapChangeOfflineConfig | 1.3.6.1.4.1.3181.10.6.1.1.13 | | | An offline configuration parameter has been modified. The running system is not affected. |
| NTF g6TrapActionResponse | 1.3.6.1.4.1.3181.10.6.1.1.14 | | | Not a customer event. Contains the reponse string to an action command. |
| NTF g6TrapCommitConfig | 1.3.6.1.4.1.3181.10.6.1.1.15 | | | Not a customer event. Recent configuration changes should now be stored and activated. |
| NTF g6TrapPowerSupplyOk | 1.3.6.1.4.1.3181.10.6.1.1.16 | | | Power supply has been restored. Applies to units with redundant supplies only. |
| NTF g6TrapPowerSupplyFail | 1.3.6.1.4.1.3181.10.6.1.1.17 | | | Power supply has FAILED. Applies to units with redundant supplies only. |
| NTF g6TrapLogin | 1.3.6.1.4.1.3181.10.6.1.1.18 | | | An operator has logged onto the system. |
| NTF g6TrapLogout | 1.3.6.1.4.1.3181.10.6.1.1.19 | | | An operator has logged off from the system. |
| NTF g6TrapLoginAttempt | 1.3.6.1.4.1.3181.10.6.1.1.20 | | | An operator login has failed due to invalid login or password. |
| NTF g6TrapLinkUp | 1.3.6.1.4.1.3181.10.6.1.1.21 | | | A port has gone online and is ready to transport data. |
| NTF g6TrapLinkDown | 1.3.6.1.4.1.3181.10.6.1.1.22 | | | A port has gone down. Data transport on this port is no longer possible. |
| NTF g6TrapRingNormal | 1.3.6.1.4.1.3181.10.6.1.1.23 | | | A ring is back to normal operation. Protection is available. |
| NTF g6TrapRingBackup | 1.3.6.1.4.1.3181.10.6.1.1.24 | | | A ring has switched to the redundant backup path. |
| NTF g6TrapRingFailure | 1.3.6.1.4.1.3181.10.6.1.1.25 | | | A ring has FAILED. Normal and backup path are unavailable. |
| NTF g6TrapCouplingState | 1.3.6.1.4.1.3181.10.6.1.1.26 | | | Coupling controller state change. |
| NTF g6TrapTemperatureOk | 1.3.6.1.4.1.3181.10.6.1.1.27 | | | Operating temperature is within acceptable limits. |
| NTF g6TrapTemperatureWarning | 1.3.6.1.4.1.3181.10.6.1.1.28 | | | Operating temperature is low or high. Performance my be degraded. Do not run under this condition for prolonged time. |
| NTF g6TrapTemperatureFailure | 1.3.6.1.4.1.3181.10.6.1.1.29 | | | Operating temperature is too low or too high. The unit may switch itself off to protect itself anytime soon. |
| NTF g6TrapMacAccepted | 1.3.6.1.4.1.3181.10.6.1.1.30 | | | A MAC address has been authorized. |
| NTF g6TrapMacAuthError | 1.3.6.1.4.1.3181.10.6.1.1.31 | | | MAC authorization error. |
| NTF g6TrapMacBlocked | 1.3.6.1.4.1.3181.10.6.1.1.32 | | | A MAC address has been blocked. |
| NTF g6TrapMacBlockedVlan | 1.3.6.1.4.1.3181.10.6.1.1.33 | | | A MAC address has been blocked. Assigned to unauthorized VLAN. |
| NTF g6TrapMacDisconnected | 1.3.6.1.4.1.3181.10.6.1.1.34 | | | A MAC address has been disconnected. |
| NTF g6TrapSfpInserted | 1.3.6.1.4.1.3181.10.6.1.1.35 | | | An SFP (pluggable optical or electrical port module) has been inserted. |
| NTF g6TrapSfpRemoved | 1.3.6.1.4.1.3181.10.6.1.1.36 | | | An SFP (pluggable optical or electrical port module) has been removed from the device. |
| NTF g6TrapSfpSignalPresent | 1.3.6.1.4.1.3181.10.6.1.1.37 | | | An SFP (pluggable optical or electrical port module) has detected an optical receive signal. |
| NTF g6TrapSfpSignalLoss | 1.3.6.1.4.1.3181.10.6.1.1.38 | | | An SFP (pluggable optical or electrical port module) has lost its receive signal. |
| NTF g6TrapSfpSignalChange | 1.3.6.1.4.1.3181.10.6.1.1.39 | | | An SFP (pluggable optical or electrical port module) has detected a change in the optical input power level. |
| NTF g6TrapSfpMismatch | 1.3.6.1.4.1.3181.10.6.1.1.40 | | | An SFP (pluggable optical or electrical port module) has been inserted which does not match the required feature(s). |
| NTF g6TrapPoeConnect | 1.3.6.1.4.1.3181.10.6.1.1.41 | | | A POE (Power over Ethernet) device is connected an powered. |
| NTF g6TrapPoeVoltage | 1.3.6.1.4.1.3181.10.6.1.1.42 | | | The POE (Power over Ethernet) operating voltage is too low. |
| NTF g6TrapPoeError | 1.3.6.1.4.1.3181.10.6.1.1.43 | | | A POE (Power over Ethernet) error has occurred. |
| NTF g6TrapPoeClassmismatch | 1.3.6.1.4.1.3181.10.6.1.1.44 | | | A POE (Power over Ethernet) powered device requires a power level not enabled or available at this port. |
| NTF g6TrapPoeDisconnect | 1.3.6.1.4.1.3181.10.6.1.1.45 | | | A POE (Power over Ethernet) device has been disconnected. |
| NTF g6TrapNtpFail | 1.3.6.1.4.1.3181.10.6.1.1.46 | | | The NTP client (Network Time Protocol) has a failure condition. |
| NTF g6TrapHardwareError | 1.3.6.1.4.1.3181.10.6.1.1.47 | | | A hardware error has been detected. |
| NTF g6TrapSoftwareError | 1.3.6.1.4.1.3181.10.6.1.1.48 | | | A software error has occured. |
| NTF g6TrapButtonPressed | 1.3.6.1.4.1.3181.10.6.1.1.49 | | | System button pressed. |
| NTF g6TrapInputSignalNormal | 1.3.6.1.4.1.3181.10.6.1.1.67 | | | An external input signal has been deactivated and returned to normal state. |
| NTF g6TrapInputSignalActivated | 1.3.6.1.4.1.3181.10.6.1.1.68 | | | An external input signal has been activated. |
| NTF g6TrapOutputRelayNormal | 1.3.6.1.4.1.3181.10.6.1.1.69 | | | A relay output signal has been deactivated and returned to normal state. |
| NTF g6TrapOutputRelayActivated | 1.3.6.1.4.1.3181.10.6.1.1.70 | | | An external input signal has been deactivated and returned to normal state. |
| NTF g6TrapPacketIntercepted | 1.3.6.1.4.1.3181.10.6.1.1.71 | | | Special filter has intercepted a data packet. |
| NTF g6TrapScriptUnitPositive | 1.3.6.1.4.1.3181.10.6.1.1.72 | | | A positive unit related user defined event created by script or app. |
| NTF g6TrapScriptUnitNegative | 1.3.6.1.4.1.3181.10.6.1.1.73 | | | A negative unit related user defined event created by script or app. |
| NTF g6TrapScriptPortPositive | 1.3.6.1.4.1.3181.10.6.1.1.74 | | | A positive port related user defined event created by script or app. |
| NTF g6TrapScriptPortNegative | 1.3.6.1.4.1.3181.10.6.1.1.75 | | | A negative port related user defined event created by script or app. |
| NTF g6TrapScriptExecuted | 1.3.6.1.4.1.3181.10.6.1.1.76 | | | A user defined script execution started. |
| NTF g6TrapScriptError | 1.3.6.1.4.1.3181.10.6.1.1.77 | | | Script execution error of a user defined script. |
| NTF g6TrapLoopRemoved | 1.3.6.1.4.1.3181.10.6.1.1.78 | | | Cable loop removed. Port unblocked. |
| NTF g6TrapLoopDetected | 1.3.6.1.4.1.3181.10.6.1.1.79 | | | Cable loop detected. Port blocked. |
| NTF g6TrapLacpConnect | 1.3.6.1.4.1.3181.10.6.1.1.80 | | | Aggregated link established. |
| NTF g6TrapLacpDisconnect | 1.3.6.1.4.1.3181.10.6.1.1.81 | | | Aggregated link down. |
| NTF g6TrapAppInstalled | 1.3.6.1.4.1.3181.10.6.1.1.82 | | | App installed ok. |
| NTF g6TrapAppInstallationFail | 1.3.6.1.4.1.3181.10.6.1.1.83 | | | App installation has failed. |
| NTF g6TrapAppDeinstalled | 1.3.6.1.4.1.3181.10.6.1.1.84 | | | App deinstalled. |
| NTF g6TrapCableChangeDetected | 1.3.6.1.4.1.3181.10.6.1.1.85 | | | Change in cable termination detected. |
| NTF g6TrapImplausibleConfig | 1.3.6.1.4.1.3181.10.6.1.1.86 | | | Implausible configuration detected |
| NTF g6TrapNetworkAttack | 1.3.6.1.4.1.3181.10.6.1.1.87 | | | Potential network attack detected |
| NTF g6TrapModuleInserted | 1.3.6.1.4.1.3181.10.6.1.1.88 | | | A hardware module has been inserted into the system. |
| NTF g6TrapModuleRemoved | 1.3.6.1.4.1.3181.10.6.1.1.89 | | | A hardware module has been removed from the system. |
| NTF g6TrapMsp1000UnitPositive | 1.3.6.1.4.1.3181.10.6.1.1.90 | | | A positive MSP1000 unit related event has occured. |
| NTF g6TrapMsp1000UnitNegative | 1.3.6.1.4.1.3181.10.6.1.1.91 | | | A negative MSP1000 unit related event has occured. |
| NTF g6TrapMsp1000PortPositive | 1.3.6.1.4.1.3181.10.6.1.1.92 | | | A positive MSP1000 port related event has occured. |
| NTF g6TrapMsp1000PortNegative | 1.3.6.1.4.1.3181.10.6.1.1.93 | | | A negative MSP1000 port related event has occured. |
| NTF g6TrapBackupTerminated | 1.3.6.1.4.1.3181.10.6.1.1.94 | | | Backup path not required. |
| NTF g6TrapBackupEngaged | 1.3.6.1.4.1.3181.10.6.1.1.95 | | | Backup path has been engaged. |
| NTF g6TrapBackupFailure | 1.3.6.1.4.1.3181.10.6.1.1.96 | | | Backup path could not be completed. |
| NTF g6TrapFanOk | 1.3.6.1.4.1.3181.10.6.1.1.97 | | | Cooling fan operating normally. |
| NTF g6TrapFanDegraded | 1.3.6.1.4.1.3181.10.6.1.1.98 | | | Cooling fan degraded. Replace fan soon. |
| NTF g6TrapFanFailure | 1.3.6.1.4.1.3181.10.6.1.1.99 | | | Cooling fan failed. Replace fan immediately |
| NTF g6TrapIncomingAlert | 1.3.6.1.4.1.3181.10.6.1.1.100 | | | Externally received HTTP_GET_REQUEST or received SNMP TRAP. |
| NTF g6TrapCableTerminationEstablished | 1.3.6.1.4.1.3181.10.6.1.1.101 | | | Cable termination established. Possible reason: A terminated remote device was connected to the cable. |
| NTF g6TrapCableTerminationLost | 1.3.6.1.4.1.3181.10.6.1.1.102 | | | Cable termination lost. Possible reason: A terminated remote device was disconnected from the cable or the cable was locally unplugged. |
| NTF g6TrapTerminalServerConnected | 1.3.6.1.4.1.3181.10.6.1.1.103 | | | Terminal server connected foreign host to local serial port. |
| NTF g6TrapTerminalServerDisconnected | 1.3.6.1.4.1.3181.10.6.1.1.104 | | | Terminal server disconnected foreign host from local serial port. |
| NTF g6TrapTerminalServerFail | 1.3.6.1.4.1.3181.10.6.1.1.105 | | | Terminal server failed in connecting foreign host to local serial port. |
| NTF g6TrapSensorGroupChange | 1.3.6.1.4.1.3181.10.6.1.1.108 | | | Sensor group values have changed. |
| NTF g6TrapActorGroupChangeRequest | 1.3.6.1.4.1.3181.10.6.1.1.110 | | | Actor group is requested to change to a new value. |
| NTF g6TrapRegisterSmartDevice | 1.3.6.1.4.1.3181.10.6.1.1.111 | | | A new smart device is registered. |
| NTF g6TrapUpdateSmartDevice | 1.3.6.1.4.1.3181.10.6.1.1.112 | | | A smart device has changed its status. |
| NTF g6TrapRegisterSmartAttribute | 1.3.6.1.4.1.3181.10.6.1.1.115 | | | A new smart attribute is registered. |
| NTF g6TrapUnregisterSmartDevice | 1.3.6.1.4.1.3181.10.6.1.1.117 | | | A smart device is unregistered. |
| NTF g6TrapUnregisterSmartAttribute | 1.3.6.1.4.1.3181.10.6.1.1.118 | | | A smart attribute is unregistered. |
| NTF g6TrapSingleActorChange | 1.3.6.1.4.1.3181.10.6.1.1.119 | | | An individual actor is set to a new value. |
| NTF g6TrapActorGroupChanged | 1.3.6.1.4.1.3181.10.6.1.1.120 | | | An actor group has changed to a new value. |
| NTF g6TrapSmartOfficeInitializing | 1.3.6.1.4.1.3181.10.6.1.1.121 | | | Smart Office is being initialized. |
| NTF g6TrapSmartOfficeStarted | 1.3.6.1.4.1.3181.10.6.1.1.122 | | | Smart Office is started and ready. |
| NTF g6TrapSmartOfficeStopped | 1.3.6.1.4.1.3181.10.6.1.1.123 | | | Smart Office is being stopped. |
| NTF g6TrapSmartOfficeError | 1.3.6.1.4.1.3181.10.6.1.1.124 | | | A Smart Office error has occured. |
| NTF g6TrapOtdrMeasurements | 1.3.6.1.4.1.3181.10.6.1.1.125 | | | An OTDR measurement has taken place and detected a change in the optical characteristics of the cable. |
| g6TrapObjects | 1.3.6.1.4.1.3181.10.6.1.2 | | | |
| STR g6TrapObjEventName | 1.3.6.1.4.1.3181.10.6.1.2.1 | DisplayString | read-only | Event name as text string. |
| INT g6TrapObjGroupName | 1.3.6.1.4.1.3181.10.6.1.2.2 | INTEGER | read-only | Event group as text string. |
| INT g6TrapObjRelevance | 1.3.6.1.4.1.3181.10.6.1.2.3 | INTEGER | read-only | pos neg info |
| INT g6TrapObjSeverity | 1.3.6.1.4.1.3181.10.6.1.2.4 | INTEGER | read-only | Severity level of this event. |
| INT g6TrapObjSource | 1.3.6.1.4.1.3181.10.6.1.2.5 | INTEGER | read-only | Unit or port related event. |
| STR g6TrapObjSysName | 1.3.6.1.4.1.3181.10.6.1.2.6 | DisplayString | read-only | User defined system name of the device originating this event. |
| I32 g6TrapObjPortId | 1.3.6.1.4.1.3181.10.6.1.2.7 | Integer32 | read-only | Port identification in snmp compliant integer format. Value is calculated as (slot * 100) + port. |
| STR g6TrapObjPortString | 1.3.6.1.4.1.3181.10.6.1.2.8 | DisplayString | read-only | Port identification in slot/port notation. |
| STR g6TrapObjPortAlias | 1.3.6.1.4.1.3181.10.6.1.2.9 | DisplayString | read-only | Port identification using a possible user assigned alias or nickname. |
| STR g6TrapObjDescription | 1.3.6.1.4.1.3181.10.6.1.2.10 | DisplayString | read-only | Detailed human readable full description of the event. |
| MAC g6TrapObjMac | 1.3.6.1.4.1.3181.10.6.1.2.11 | MacAddress | read-only | MAC address related with authentication trap. |
| I32 g6TrapObjVlanId | 1.3.6.1.4.1.3181.10.6.1.2.12 | Integer32 | read-only | Associated VLAN id. |
| STR g6TrapObjOfficeGroupName | 1.3.6.1.4.1.3181.10.6.1.2.13 | DisplayString | read-only | SmartOffice actor or sensor group name. |
| STR g6TrapObjAvgValue | 1.3.6.1.4.1.3181.10.6.1.2.14 | DisplayString | read-only | SmartOffice group data value. Contains the average value of all elements in the same group |
| STR g6TrapObjTotalValue | 1.3.6.1.4.1.3181.10.6.1.2.15 | DisplayString | read-only | SmartOffice group data value. Contains the total value of all elements in the same group |