All MIBs › MICROSENS-G6-NOTIFICATION-MIB › g6TrapObjSysName
g6TrapObjSysName
Module: MICROSENS-G6-NOTIFICATION-MIB
OID (symbolic): MICROSENS-G6-NOTIFICATION-MIB::g6TrapObjSysName
OID (numeric): 1.3.6.1.4.1.3181.10.6.1.2.6
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-only
Description: User defined system name of the device originating this event.
What is g6TrapObjSysName?
This object reports the user-configured system name of the Microsens switch that generated the event, as set locally on the device. It helps an admin immediately identify which switch in a multi-device deployment raised the trap without cross-referencing an IP address. For example, a NOC dashboard could group incoming g6Trap notifications by this field to show that 'switch-floor3-rackA' is reporting repeated login failures.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.1.2.6 snmpwalk -v2c -c public <target> MICROSENS-G6-NOTIFICATION-MIB::g6TrapObjSysName
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.1.2.6.1 snmpget -v2c -c public <target> MICROSENS-G6-NOTIFICATION-MIB::g6TrapObjSysName.1
Start monitoring MICROSENS Generation 6 Ethernet switching equipment (notifications) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the MICROSENS-G6-NOTIFICATION-MIB::g6TrapObjSysName OID value, configure state conditions and alerts, and monitor any MICROSENS Generation 6 Ethernet switching equipment (notifications) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.3181 | microsens | MICROSENS-G6-MIB |
| 1.3.6.1.4.1.3181.10 | managedSwitches | MICROSENS-G6-MIB |
| 1.3.6.1.4.1.3181.10.6 | g6 | MICROSENS-G6-MIB |
| 1.3.6.1.4.1.3181.10.6.1 | device | G6-FACTORY-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3181.10.6.1.2 | g6TrapObjects | MICROSENS-G6-NOTIFICATION-MIB |
| 1.3.6.1.4.1.3181.10.6.1.2.6 | g6TrapObjSysName | MICROSENS-G6-NOTIFICATION-MIB |