All MIBs › LaserJet-Series8000-Stapler-MIB › prtinputnextindex
prtinputnextindex
Module: LaserJet-Series8000-Stapler-MIB
OID (symbolic): LaserJet-Series8000-Stapler-MIB::prtinputnextindex
OID (numeric): 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.26
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The value of prtInputIndex corresponding to the input subunit which will be used when this input subunit is emptied and the timeout specified by prtInputMediaLoadTimeout expires. A value of zero(0) indicates that auto input switching will not occur when this input subunit is emptied. If the timeout specified by prtInputLoadMediaTimeout expires and this value is zero(0), the job will be aborted. A value of (-1) means other. The value (-2) means 'unknown' and specifically indicates that an implementation specific method will determine the next input subunit to use at the time this subunit is emptied and the timeout expires. The value(-3) means input switching is not supported for this subunit. Refer to ftp://ftp.pwg.org/pub/pwg/pmp/drafts/pmib_031698.txt, for more details in the Standard Printer MIB. Additional information: This object reflects the state of JOB-INPUT-AUTO-CONTINUE-MODE and JOB-INPUT-AUTO-CONTINUE-TIMEOUT. If JOB-INPUT-AUTO-CONTINUE-TIMEOUT is set to -1 or JOB-INPUT-AUTO-CONTINUE-MODE is set up to cancel the job, this object will return 0. If JOB-INPUT-AUTO-CONTINUE-TIMEOUT is >= 0 and JOB-INPUT-AUTO-CONTINUE-MODE is not set up to cancel the job, this object will return -2, meaning that a product-specific tray switching action will occur.
What is prtinputnextindex?
Identifies which input tray index the printer will automatically switch to once the current tray is emptied and its load timeout expires. It reflects the combination of JOB-INPUT-AUTO-CONTINUE-MODE and -TIMEOUT: a value of 0 means no auto-switch occurs and the job aborts when the timeout hits, while -2 means a product-specific switching decision will be made at that time. For example, tray 1 reporting a prtinputnextindex of 3 tells an admin that when tray 1 empties, the printer will automatically fall back to tray 3.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.26 snmpwalk -v2c -c public <target> LaserJet-Series8000-Stapler-MIB::prtinputnextindex
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.26.1 snmpget -v2c -c public <target> LaserJet-Series8000-Stapler-MIB::prtinputnextindex.1
Start monitoring HP LaserJet 8000 series printer with stapler/finisher accessory with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LaserJet-Series8000-Stapler-MIB::prtinputnextindex OID value, configure state conditions and alerts, and monitor any HP LaserJet 8000 series printer with stapler/finisher accessory from a single console.
OID Breakdown
Upper-level ancestors (16 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3 | hpsystem | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3.9 | net_peripheral | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3.9.4 | netdm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3.9.4.2 | dm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3.9.4.2.2 | printmib | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8 | prtInput | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2 | prtInputTable | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1 | prtInputEntry | CLJ8500-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.3.9.4.2.2.8.2.1.26 | prtinputnextindex | LaserJet-Series8000-Stapler-MIB |