| OID symbolic | OID numeric | Type | Access | Description |
| org | 1.3 | | | |
| dod | 1.3.6 | | | |
| internet | 1.3.6.1 | | | |
| private | 1.3.6.1.4 | | | |
| enterprises | 1.3.6.1.4.1 | | | |
| lenovoemc | 1.3.6.1.4.1.11369 | | | MIB for Iomega NAS |
| iomegaNAS | 1.3.6.1.4.1.11369.10 | | | |
| iomegaNASInfo | 1.3.6.1.4.1.11369.10.1 | | | |
| STR deviceDescr | 1.3.6.1.4.1.11369.10.1.1 | DisplayString | read-only | Description of this device. |
| STR deviceName | 1.3.6.1.4.1.11369.10.1.2 | DisplayString | read-only | Iomega NAS host name. |
| netConfig | 1.3.6.1.4.1.11369.10.1.3 | | | |
| IP dns0 | 1.3.6.1.4.1.11369.10.1.3.1 | IpAddress | read-only | The first DNS server |
| IP dns1 | 1.3.6.1.4.1.11369.10.1.3.2 | IpAddress | read-only | Backup DNS server |
| IP wins0 | 1.3.6.1.4.1.11369.10.1.3.3 | IpAddress | read-only | The first wins server |
| IP wins1 | 1.3.6.1.4.1.11369.10.1.3.4 | IpAddress | read-only | Backup wins server |
| systemPerformance | 1.3.6.1.4.1.11369.10.2 | | | |
| ioTable | 1.3.6.1.4.1.11369.10.2.1 | | not-accessible | A table of disk I/O performance. |
| ioEntry | 1.3.6.1.4.1.11369.10.2.1.1 | | not-accessible | An entry of one disk I/O performance. |
| I32 ioIndex | 1.3.6.1.4.1.11369.10.2.1.1.1 | Integer32 | not-accessible | ioIndex |
| OCT diskName | 1.3.6.1.4.1.11369.10.2.1.1.2 | OCTET STRING | read-only | Disk names such as sda and so on |
| OCT ioMgrs | 1.3.6.1.4.1.11369.10.2.1.1.3 | OCTET STRING | read-only | Read merges per second. |
| OCT ioMgws | 1.3.6.1.4.1.11369.10.2.1.1.4 | OCTET STRING | read-only | Write merges per second. |
| OCT ioReqrs | 1.3.6.1.4.1.11369.10.2.1.1.5 | OCTET STRING | read-only | Read io requests per second. |
| OCT ioReqws | 1.3.6.1.4.1.11369.10.2.1.1.6 | OCTET STRING | read-only | Write io requests per second. |
| OCT ioKbrs | 1.3.6.1.4.1.11369.10.2.1.1.7 | OCTET STRING | read-only | Kilobytes read per second. |
| OCT ioKbws | 1.3.6.1.4.1.11369.10.2.1.1.8 | OCTET STRING | read-only | Kilobytes written per second. |
| OCT ioAvgQueue | 1.3.6.1.4.1.11369.10.2.1.1.9 | OCTET STRING | read-only | Average queue length. |
| OCT ioAvgWait | 1.3.6.1.4.1.11369.10.2.1.1.10 | OCTET STRING | read-only | Average waiting time (queue + service) |
| OCT ioAvgSvc | 1.3.6.1.4.1.11369.10.2.1.1.11 | OCTET STRING | read-only | Average service time at disk. |
| OCT ioAvgUtil | 1.3.6.1.4.1.11369.10.2.1.1.12 | OCTET STRING | read-only | Average disk utilization. |
| OCT ioCpuTime | 1.3.6.1.4.1.11369.10.2.1.1.13 | OCTET STRING | read-only | Percentage of CPU time during which I/O requests were issued to the device. |
| iomegaNASFunctionStatus | 1.3.6.1.4.1.11369.10.3 | | | |
| bkupTable | 1.3.6.1.4.1.11369.10.3.1 | | not-accessible | A table of backup status. |
| bkupEntry | 1.3.6.1.4.1.11369.10.3.1.1 | | not-accessible | An entry of backup status. |
| I32 bkupIndex | 1.3.6.1.4.1.11369.10.3.1.1.1 | Integer32 | not-accessible | Record backup status |
| OCT bkupClient | 1.3.6.1.4.1.11369.10.3.1.1.2 | OCTET STRING | read-only | Client Name |
| OCT bkupltStatus | 1.3.6.1.4.1.11369.10.3.1.1.3 | OCTET STRING | read-only | Last backup status |
| OCT bkupTotalSpace | 1.3.6.1.4.1.11369.10.3.1.1.4 | OCTET STRING | read-only | Total space |
| remoteAccess | 1.3.6.1.4.1.11369.10.3.2 | | | |
| I32 raEnabled | 1.3.6.1.4.1.11369.10.3.2.1 | Integer32 | read-only | Whether RA is enabled
0 Disable
1 Enable |
| conTable | 1.3.6.1.4.1.11369.10.3.3 | | not-accessible | Table for connected client count |
| conEntry | 1.3.6.1.4.1.11369.10.3.3.1 | | not-accessible | Entry for connected client count |
| I32 conIndex | 1.3.6.1.4.1.11369.10.3.3.1.1 | Integer32 | not-accessible | Index for entry |
| I32 conCount | 1.3.6.1.4.1.11369.10.3.3.1.2 | Integer32 | read-only | Connected client count for a given protocol |
| STR conProtocol | 1.3.6.1.4.1.11369.10.3.3.1.3 | DisplayString | read-only | Protocol used by this kind of clients |
| mediaService | 1.3.6.1.4.1.11369.10.3.4 | | | |
| I32 mediaServiceEnabled | 1.3.6.1.4.1.11369.10.3.4.1 | Integer32 | read-only | Whether media service is enabled
0 disable
1 enable |
| iomegaNASStorage | 1.3.6.1.4.1.11369.10.4 | | | |
| OCT raidStatus | 1.3.6.1.4.1.11369.10.4.1 | OCTET STRING | read-only | Description of raid status. There are five different status:
NORMAL
REBUILDING
DEGRADED
REBUILDFS
FAULTED |
| I32 raidLevel | 1.3.6.1.4.1.11369.10.4.2 | Integer32 | read-only | Raid level(5/10) |
| diskTable | 1.3.6.1.4.1.11369.10.4.3 | | not-accessible | The table of disks that build the RAID. |
| diskEntry | 1.3.6.1.4.1.11369.10.4.3.1 | | not-accessible | An entry of one disk. |
| I32 diskIndex | 1.3.6.1.4.1.11369.10.4.3.1.1 | Integer32 | not-accessible | Index of disk entry |
| OCT diskID | 1.3.6.1.4.1.11369.10.4.3.1.2 | OCTET STRING | read-only | ID of disk in array |
| OCT diskSize | 1.3.6.1.4.1.11369.10.4.3.1.3 | OCTET STRING | read-only | Capacity of disk |
| OCT diskStatus | 1.3.6.1.4.1.11369.10.4.3.1.4 | OCTET STRING | read-only | Status of Disk. There are four status:
NORMAL
FOREIGN
FAULTED
MISSING |
| iomegaNASDevice | 1.3.6.1.4.1.11369.10.5 | | | |
| usbTable | 1.3.6.1.4.1.11369.10.5.1 | | not-accessible | Table of connected usb devices. |
| usbEntry | 1.3.6.1.4.1.11369.10.5.1.1 | | not-accessible | Entry for connected USB device |
| I32 usbIndex | 1.3.6.1.4.1.11369.10.5.1.1.1 | Integer32 | not-accessible | Index for entry in the table |
| STR usbManufacture | 1.3.6.1.4.1.11369.10.5.1.1.2 | DisplayString | read-only | Manufucture of the device |
| STR usbModel | 1.3.6.1.4.1.11369.10.5.1.1.3 | DisplayString | read-only | Model of the USB device |
| I32 usbType | 1.3.6.1.4.1.11369.10.5.1.1.4 | Integer32 | read-only | USB device type(such UPS(3), PTP(6), printer(7) and so on) |
| iomegaNASSensor | 1.3.6.1.4.1.11369.10.6 | | | |
| fanTable | 1.3.6.1.4.1.11369.10.6.1 | | not-accessible | Table for fan sensors |
| fanEntry | 1.3.6.1.4.1.11369.10.6.1.1 | | not-accessible | Entry for fan sensor |
| I32 fanIndex | 1.3.6.1.4.1.11369.10.6.1.1.1 | Integer32 | not-accessible | Index for the entry |
| STR fanName | 1.3.6.1.4.1.11369.10.6.1.1.2 | DisplayString | read-only | Name of the fan sensor |
| G32 fanValueEx | 1.3.6.1.4.1.11369.10.6.1.1.3 | Gauge32 | read-only | Rotation speed of the fan in RPM |
| tempTable | 1.3.6.1.4.1.11369.10.6.2 | | not-accessible | Table for temperature sensor |
| tempEntry | 1.3.6.1.4.1.11369.10.6.2.1 | | not-accessible | Entry for temperature sensor |
| I32 tempIndex | 1.3.6.1.4.1.11369.10.6.2.1.1 | Integer32 | not-accessible | Index for entry |
| STR tempName | 1.3.6.1.4.1.11369.10.6.2.1.2 | DisplayString | read-only | Name of the temperature sensor |
| G32 tempValue | 1.3.6.1.4.1.11369.10.6.2.1.3 | Gauge32 | read-only | The temperature of the sensor in mC. |
| voltTable | 1.3.6.1.4.1.11369.10.6.3 | | not-accessible | Table for volt sensor |
| voltEntry | 1.3.6.1.4.1.11369.10.6.3.1 | | not-accessible | Entry for volt sensor |
| I32 voltIndex | 1.3.6.1.4.1.11369.10.6.3.1.1 | Integer32 | not-accessible | Index for the entry |
| STR voltName | 1.3.6.1.4.1.11369.10.6.3.1.2 | DisplayString | read-only | Name of the volt sensor |
| G32 voltValue | 1.3.6.1.4.1.11369.10.6.3.1.3 | Gauge32 | read-only | The voltage in mV |
| iomegaNASEvent | 1.3.6.1.4.1.11369.10.7 | | | |
| STR eventID | 1.3.6.1.4.1.11369.10.7.1 | DisplayString | read-only | ID of the event |
| STR eventText | 1.3.6.1.4.1.11369.10.7.2 | DisplayString | read-only | Description of the event. |
| iomegaNASNotifications | 1.3.6.1.4.1.11369.10.8 | | | |
| NTF iomegaNASNotificationError | 1.3.6.1.4.1.11369.10.8.1 | | | An Error EventMonitorTrap is generated in response to a user-specified event. Details can be found in Variables data. |
| NTF iomegaNASNotificationWarn | 1.3.6.1.4.1.11369.10.8.2 | | | A Warning EventMonitorTrap is generated in response to a user-specified event. Details can be found in Variables data. |
| NTF iomegaNASNotificationInfo | 1.3.6.1.4.1.11369.10.8.3 | | | An Informational EventMonitorTrap is generated in response to a user-specified event. Details can be found in Variables data. |