All MIBs › ISILON-TRAP-MIB
Organization: Isilon Systems LLC
Last Updated: 2015-12-18
Category: Alarm and Event Management, Domain: Storage, Vendor: EMC, Vendor: Isilon
Description: Isilon Systems NAS trap MIB defining SNMP notification objects for cluster events, disk failures, and quota threshold alerts.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is ISILON-TRAP-MIB?
ISILON-TRAP-MIB is the companion notification MIB to ISILON-MIB, defining the SNMP traps Isilon OneFS clusters send for fault and threshold-crossing conditions rather than pollable status objects. It carries varbinds identifying the affected node, the measured value and its units, relevant object identifiers, and contextual fields like bay, interface name, and error codes/messages. Its purpose is explicitly fault and event monitoring: traps grouped under categories like group-state changes (cluster membership events), filesystem traps (disk/filesystem issues), and smart-quota traps (storage quota threshold breaches), giving near-real-time notice of hardware or software problems such as a failed disk bay or a filesystem nearing capacity. It is designed to work alongside ISILON-MIB, whose polled objects provide the steady-state context that these traps interrupt. Deployment context is the same Isilon OneFS clusters as ISILON-MIB, configured to send SNMP traps to a monitoring station for alerting. Engineers can download the ISILON-TRAP-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in ISILON-TRAP-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Isilon (EMC/Dell) OneFS scale-out NAS cluster
Monitoring Examples
A monitoring station receiving a trap from the filesystemTraps group would inspect nodeIdentifier and bay to pinpoint which node and disk bay triggered the event, along with errorMessage and errno for the specific failure cause. A smartQuotaTraps notification would include measuredValue and units to show how far a quota has been exceeded. groupStateTraps notify when cluster group membership changes, such as a node leaving the cluster, complementing the onlineNodes/offlineNodes counters in ISILON-MIB.
What Can Be Monitored
- disk/filesystem fault events
- cluster group membership changes
- storage quota threshold breaches
- affected node and bay identification
- error codes and messages
This MIB depends on
Related MIBs
Imported Objects
From ISILON-MIB
| isilon | MODULE-IDENTITY |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Counter64 | |
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| isilonTraps | 1.3.6.1.4.1.12124.250 | Traps for Isilon Systems OneFS operating system. | ||
| groupStateTraps | 1.3.6.1.4.1.12124.250.10 | |||
| nodeStatus | 1.3.6.1.4.1.12124.250.10.1 | |||
| NTF nodeStatusCrit | 1.3.6.1.4.1.12124.250.10.1.3 | A critical node status event has occurred. | ||
| NTF nodeStatusInfo | 1.3.6.1.4.1.12124.250.10.1.7 | A node status event has occurred. | ||
| nodeExpStatus | 1.3.6.1.4.1.12124.250.10.2 | |||
| NTF nodeExpStatusCrit | 1.3.6.1.4.1.12124.250.10.2.3 | A disk-only node has gone offline and cannot be contacted by the cluster. | ||
| nodeShutdown | 1.3.6.1.4.1.12124.250.10.3 | |||
| NTF nodeShutdownInfo | 1.3.6.1.4.1.12124.250.10.3.7 | A node is being shut down or rebooted. | ||
| nodeShutdownFail | 1.3.6.1.4.1.12124.250.10.4 | |||
| NTF nodeShutdownFailCrit | 1.3.6.1.4.1.12124.250.10.4.3 | Shut down or reboot failed for a node. | ||
| nodeRebootCoalesced | 1.3.6.1.4.1.12124.250.10.20 | |||
| NTF nodeRebootCoalescedInfo | 1.3.6.1.4.1.12124.250.10.20.7 | A node is being rebooted. | ||
| nodeStatusCoalescing | 1.3.6.1.4.1.12124.250.10.21 | |||
| NTF nodeStatusCoalescingCrit | 1.3.6.1.4.1.12124.250.10.21.3 | Critical node status events are occurring | ||
| NTF nodeStatusCoalescingWarn | 1.3.6.1.4.1.12124.250.10.21.5 | Warning node status events are occurring | ||
| filesystemTraps | 1.3.6.1.4.1.12124.250.11 | |||
| partitionUsage | 1.3.6.1.4.1.12124.250.11.1 | |||
| NTF partitionUsageCrit | 1.3.6.1.4.1.12124.250.11.1.3 | A partition is over the critical threshold percentage. | ||
| NTF partitionUsageWarn | 1.3.6.1.4.1.12124.250.11.1.5 | A partition is over the warning threshold percentage. | ||
| NTF partitionUsageInfo | 1.3.6.1.4.1.12124.250.11.1.7 | A partition is over the info threshold percentage. | ||
| clusterStorageUsage | 1.3.6.1.4.1.12124.250.11.2 | |||
| NTF clusterStorageUsageCrit | 1.3.6.1.4.1.12124.250.11.2.3 | The /ifs partition is near capacity. | ||
| NTF clusterStorageUsageWarn | 1.3.6.1.4.1.12124.250.11.2.5 | The /ifs partition is near capacity. | ||
| filesysError | 1.3.6.1.4.1.12124.250.11.3 | |||
| NTF filesysErrorCrit | 1.3.6.1.4.1.12124.250.11.3.3 | A critical /ifs filesystem error has occurred | ||
| NTF filesysErrorWarn | 1.3.6.1.4.1.12124.250.11.3.5 | A warning-level /ifs filesystem error has occurred | ||
| NTF filesysErrorInfo | 1.3.6.1.4.1.12124.250.11.3.7 | An /ifs filesystem error has occurred. | ||
| diskPoolUsage | 1.3.6.1.4.1.12124.250.11.4 | |||
| NTF diskPoolUsageCrit | 1.3.6.1.4.1.12124.250.11.4.3 | A disk pool is near capacity. | ||
| NTF diskPoolUsageWarn | 1.3.6.1.4.1.12124.250.11.4.5 | A disk pool is near capacity. | ||
| diskPoolOldDbVersion | 1.3.6.1.4.1.12124.250.11.5 | |||
| NTF diskPoolOldDbVersionWarn | 1.3.6.1.4.1.12124.250.11.5.5 | The SmartPools upgrade has not completed. | ||
| ssdUsage | 1.3.6.1.4.1.12124.250.11.6 | |||
| NTF ssdUsageCrit | 1.3.6.1.4.1.12124.250.11.6.1 | The SSD drives are at capacity. | ||
| NTF ssdUsageWarn | 1.3.6.1.4.1.12124.250.11.6.2 | The SSD drives are near capacity. | ||
| NTF ssdUsageInfo | 1.3.6.1.4.1.12124.250.11.6.3 | The SSD drives are near capacity. | ||
| filesysCoalesce | 1.3.6.1.4.1.12124.250.11.20 | |||
| NTF filesysCoalesceCrit | 1.3.6.1.4.1.12124.250.11.20.3 | Filesystem issues are occurring at a critical level | ||
| NTF filesysCoalesceWarn | 1.3.6.1.4.1.12124.250.11.20.5 | Filesystem issues are occurring at a warning level | ||
| smartQuotaTraps | 1.3.6.1.4.1.12124.250.12 | |||
| quotaThreshError | 1.3.6.1.4.1.12124.250.12.1 | |||
| NTF quotaThreshErrorInfo | 1.3.6.1.4.1.12124.250.12.1.7 | SmartQuotas threshold violation | ||
| quotaNotifyError | 1.3.6.1.4.1.12124.250.12.2 | |||
| NTF quotaNotifyErrorWarn | 1.3.6.1.4.1.12124.250.12.2.5 | SmartQuotas threshold notification failed | ||
| quotaError | 1.3.6.1.4.1.12124.250.12.3 | |||
| NTF quotaErrorWarn | 1.3.6.1.4.1.12124.250.12.3.5 | SmartQuotas error | ||
| snapshotTraps | 1.3.6.1.4.1.12124.250.13 | |||
| snapshotError | 1.3.6.1.4.1.12124.250.13.1 | |||
| NTF snapshotErrorWarn | 1.3.6.1.4.1.12124.250.13.1.5 | Snapshot error | ||
| snapshotReserve | 1.3.6.1.4.1.12124.250.13.2 | |||
| NTF snapshotReserveCrit | 1.3.6.1.4.1.12124.250.13.2.3 | Snapshot reserve space is over its critical limit | ||
| NTF snapshotReserveWarn | 1.3.6.1.4.1.12124.250.13.2.5 | Snapshot reserve space is over its warning limit | ||
| syncIQTraps | 1.3.6.1.4.1.12124.250.14 | |||
| siqEvent | 1.3.6.1.4.1.12124.250.14.1 | |||
| NTF siqEventCrit | 1.3.6.1.4.1.12124.250.14.1.3 | SyncIQ event | ||
| NTF siqEventWarn | 1.3.6.1.4.1.12124.250.14.1.5 | SyncIQ event | ||
| siqError | 1.3.6.1.4.1.12124.250.14.2 | |||
| NTF siqErrorWarn | 1.3.6.1.4.1.12124.250.14.2.5 | SyncIQ error | ||
| siqPolicyCoalesced | 1.3.6.1.4.1.12124.250.14.20 | |||
| NTF siqPolicyCoalescedCrit | 1.3.6.1.4.1.12124.250.14.20.3 | SyncIQ policy errors are occurring | ||
| NTF siqPolicyCoalescedWarn | 1.3.6.1.4.1.12124.250.14.20.5 | SyncIQ policy errors are occurring | ||
| siqTargetCoalesced | 1.3.6.1.4.1.12124.250.14.21 | |||
| NTF siqTargetCoalescedCrit | 1.3.6.1.4.1.12124.250.14.21.3 | SyncIQ errors are occurring for target | ||
| NTF siqTargetCoalescedWarn | 1.3.6.1.4.1.12124.250.14.21.5 | SyncIQ errors are occurring for target | ||
| softwareTraps | 1.3.6.1.4.1.12124.250.15 | |||
| jobEngineError | 1.3.6.1.4.1.12124.250.15.1 | |||
| NTF jobEngineErrorEmerg | 1.3.6.1.4.1.12124.250.15.1.1 | The cluster encountered one or more job failures. | ||
| NTF jobEngineErrorCrit | 1.3.6.1.4.1.12124.250.15.1.3 | The cluster encountered one or more job failures. | ||
| NTF jobEngineErrorWarn | 1.3.6.1.4.1.12124.250.15.1.5 | The cluster encountered one or more job failures. | ||
| NTF jobEngineErrorInfo | 1.3.6.1.4.1.12124.250.15.1.7 | The cluster encountered one or more job failures. | ||
| flexProtectRunning | 1.3.6.1.4.1.12124.250.15.2 | |||
| NTF flexProtectRunningCrit | 1.3.6.1.4.1.12124.250.15.2.3 | Cluster is in need of restripe but FlexProtect is not running | ||
| NTF flexProtectRunningWarn | 1.3.6.1.4.1.12124.250.15.2.5 | Cluster is in need of restripe but FlexProtect is not running | ||
| NTF flexProtectRunningInfo | 1.3.6.1.4.1.12124.250.15.2.7 | Cluster is in need of restripe but FlexProtect is not running | ||
| avscanInfectedFile | 1.3.6.1.4.1.12124.250.15.3 | |||
| NTF avscanInfectedFileCrit | 1.3.6.1.4.1.12124.250.15.3.3 | AVScan found an infected file | ||
| NTF avscanInfectedFileWarn | 1.3.6.1.4.1.12124.250.15.3.5 | AVScan found an infected file | ||
| NTF avscanInfectedFileInfo | 1.3.6.1.4.1.12124.250.15.3.7 | AVScan found an infected file | ||
| mcpProcFailed | 1.3.6.1.4.1.12124.250.15.5 | |||
| NTF mcpProcFailedWarn | 1.3.6.1.4.1.12124.250.15.5.5 | MCP reports a process has failed on a node | ||
| mcpProcKilled | 1.3.6.1.4.1.12124.250.15.6 | |||
| NTF mcpProcKilledWarn | 1.3.6.1.4.1.12124.250.15.6.5 | MCP killed a process on a node | ||
| licenseExpiration | 1.3.6.1.4.1.12124.250.15.7 | |||
| NTF licenseExpirationWarn | 1.3.6.1.4.1.12124.250.15.7.5 | One or more licenses has expired | ||
| NTF licenseExpirationInfo | 1.3.6.1.4.1.12124.250.15.7.7 | One or more licenses is about to expire | ||
| firmwareUpdateIncomplete | 1.3.6.1.4.1.12124.250.15.8 | |||
| NTF firmwareUpdateIncompleteWarn | 1.3.6.1.4.1.12124.250.15.8.5 | A firmware update was not completely applied | ||
| testEvent | 1.3.6.1.4.1.12124.250.15.9 | |||
| NTF testEventCrit | 1.3.6.1.4.1.12124.250.15.9.3 | Test event | ||
| nodeCPU | 1.3.6.1.4.1.12124.250.15.10 | |||
| NTF nodeCPUWarn | 1.3.6.1.4.1.12124.250.15.10.5 | A node has exceeded the Warning-level CPU utilization. | ||
| NTF nodeCPUInfo | 1.3.6.1.4.1.12124.250.15.10.7 | A node has exceeded the Info-level CPU utilization. | ||
| mountdClientMountFailed | 1.3.6.1.4.1.12124.250.15.11 | |||
| NTF mountdClientMountFailedInfo | 1.3.6.1.4.1.12124.250.15.11.7 | Mountd denied client mount request | ||
| mountdHostLookupFailed | 1.3.6.1.4.1.12124.250.15.12 | |||
| NTF mountdHostLookupFailedInfo | 1.3.6.1.4.1.12124.250.15.12.7 | Mountd host lookup failed | ||
| mixedSedNonSedCluster | 1.3.6.1.4.1.12124.250.15.13 | |||
| NTF mixedSedNonSedClusterCrit | 1.3.6.1.4.1.12124.250.15.13.3 | Cluster contains a mix of encrypting nodes and non-encrypting nodes | ||
| nfsCookieTranslationFailed | 1.3.6.1.4.1.12124.250.15.15 | |||
| NTF nfsCookieTranslationFailedInfo | 1.3.6.1.4.1.12124.250.15.15.1 | 64bit to 32bit cookie translation failed | ||
| avscanTraps | 1.3.6.1.4.1.12124.250.16 | |||
| avscanNoServersConf | 1.3.6.1.4.1.12124.250.16.1 | |||
| NTF avscanNoServersConfCrit | 1.3.6.1.4.1.12124.250.16.1.3 | No ICAP servers configured for AVScan | ||
| NTF avscanNoServersConfWarn | 1.3.6.1.4.1.12124.250.16.1.5 | No ICAP servers configured for AVScan | ||
| NTF avscanNoServersConfInfo | 1.3.6.1.4.1.12124.250.16.1.7 | No ICAP servers configured for AVScan | ||
| avscanError | 1.3.6.1.4.1.12124.250.16.2 | |||
| NTF avscanErrorCrit | 1.3.6.1.4.1.12124.250.16.2.3 | AVscan has encountered an error | ||
| NTF avscanErrorWarn | 1.3.6.1.4.1.12124.250.16.2.5 | AVscan has encountered an error | ||
| NTF avscanErrorInfo | 1.3.6.1.4.1.12124.250.16.2.7 | AVscan has encountered an error | ||
| avscanCoalesced | 1.3.6.1.4.1.12124.250.16.20 | |||
| NTF avscanCoalescedInfo | 1.3.6.1.4.1.12124.250.16.20.3 | AVScan is detecting problems | ||
| NTF avscanCoalescedWarn | 1.3.6.1.4.1.12124.250.16.20.5 | AVScan is detecting problems | ||
| NTF avscanCoalescedCrit | 1.3.6.1.4.1.12124.250.16.20.7 | AVscan is detecting critical problems | ||
| netProtoTraps | 1.3.6.1.4.1.12124.250.17 | |||
| clockSkew | 1.3.6.1.4.1.12124.250.17.1 | |||
| NTF clockSkewCrit | 1.3.6.1.4.1.12124.250.17.1.3 | Windows ADS time skew outside limits. | ||
| sharePermsUpgradeFail | 1.3.6.1.4.1.12124.250.17.2 | |||
| NTF sharePermsUpgradeFailCrit | 1.3.6.1.4.1.12124.250.17.2.3 | Windows share permissions upgrade failed | ||
| winTimeConnectivityLost | 1.3.6.1.4.1.12124.250.17.3 | |||
| NTF winTimeConnectivityLostWarn | 1.3.6.1.4.1.12124.250.17.3.5 | Connectivity to the Windows Time server was lost | ||
| winNetMapFull | 1.3.6.1.4.1.12124.250.17.4 | |||
| NTF winNetMapFullCrit | 1.3.6.1.4.1.12124.250.17.4.3 | Windows ID map range is full. Authentication may fail. | ||
| winNetAuth | 1.3.6.1.4.1.12124.250.17.5 | |||
| NTF winNetAuthCrit | 1.3.6.1.4.1.12124.250.17.5.3 | Active Directory connectivity failure | ||
| NTF winNetAuthWarn | 1.3.6.1.4.1.12124.250.17.5.5 | Active Directory connectivity issue | ||
| lwioParam | 1.3.6.1.4.1.12124.250.17.6 | |||
| NTF lwioParamCrit | 1.3.6.1.4.1.12124.250.17.6.3 | LWIO Parameter Invalid | ||
| winSmbUpgrade | 1.3.6.1.4.1.12124.250.17.7 | |||
| NTF winSmbUpgradeWarn | 1.3.6.1.4.1.12124.250.17.7.2 | Windows networking | ||
| NTF winSmbUpgradeCrit | 1.3.6.1.4.1.12124.250.17.7.3 | Windows networking | ||
| winNetworkCoalesce | 1.3.6.1.4.1.12124.250.17.20 | |||
| NTF winNetworkCoalesceCrit | 1.3.6.1.4.1.12124.250.17.20.3 | There are problems with Windows networking components | ||
| NTF winNetworkCoalesceWarn | 1.3.6.1.4.1.12124.250.17.20.5 | There are problems with Windows networking components | ||
| winIDmapCoalesce | 1.3.6.1.4.1.12124.250.17.21 | |||
| NTF winIDmapCoalesceCrit | 1.3.6.1.4.1.12124.250.17.21.3 | There are problems with the Windows ID map | ||
| NTF winIDmapCoalesceWarn | 1.3.6.1.4.1.12124.250.17.21.5 | There are problems with the Windows ID map | ||
| winAuthCoalesce | 1.3.6.1.4.1.12124.250.17.22 | |||
| NTF winAuthCoalesceCrit | 1.3.6.1.4.1.12124.250.17.22.3 | There are problems with Windows authentication components | ||
| NTF winAuthCoalesceWarn | 1.3.6.1.4.1.12124.250.17.22.5 | There are problems with Windows authentication components | ||
| winAuthUpgrade | 1.3.6.1.4.1.12124.250.17.23 | |||
| NTF winAuthUpgradeCrit | 1.3.6.1.4.1.12124.250.17.23.3 | There are problems with upgrading authentication components | ||
| networkingTraps | 1.3.6.1.4.1.12124.250.18 | |||
| netStatus | 1.3.6.1.4.1.12124.250.18.1 | |||
| NTF netStatusCrit | 1.3.6.1.4.1.12124.250.18.1.3 | A network interface is down | ||
| NTF netStatusWarn | 1.3.6.1.4.1.12124.250.18.1.5 | A network interface is degraded or down | ||
| netStatusCoalescing | 1.3.6.1.4.1.12124.250.18.20 | |||
| NTF netStatusCoalescingCrit | 1.3.6.1.4.1.12124.250.18.20.3 | Critical network problems are occurring | ||
| NTF netStatusCoalescingWarn | 1.3.6.1.4.1.12124.250.18.20.5 | Warning network problems are occurring | ||
| hardwareTraps | 1.3.6.1.4.1.12124.250.19 | |||
| hardwareError | 1.3.6.1.4.1.12124.250.19.1 | |||
| hardwareErrorMsg | 1.3.6.1.4.1.12124.250.19.1.1 | |||
| NTF hardwareErrorMsgCrit | 1.3.6.1.4.1.12124.250.19.1.1.3 | There is a message concerning a hardware faliure | ||
| NTF hardwareErrorMsgWarn | 1.3.6.1.4.1.12124.250.19.1.1.5 | There is a message concerning a potential hardware faliure | ||
| NTF hardwareErrorCrit | 1.3.6.1.4.1.12124.250.19.1.3 | A critical hardware error has occurred. | ||
| NTF hardwareErrorWarn | 1.3.6.1.4.1.12124.250.19.1.5 | A node has a hardware error | ||
| NTF hardwareErrorInfo | 1.3.6.1.4.1.12124.250.19.1.7 | A hardware problem is occurring. | ||
| hwError | 1.3.6.1.4.1.12124.250.19.2 | |||
| NTF hwErrorCrit | 1.3.6.1.4.1.12124.250.19.2.3 | Power Supply AC Failiure. | ||
| diskNodeOffline | 1.3.6.1.4.1.12124.250.19.10 | |||
| NTF diskNodeOfflineCrit | 1.3.6.1.4.1.12124.250.19.10.3 | The expander is offline | ||
| hardwareCoalesced | 1.3.6.1.4.1.12124.250.19.20 | |||
| NTF hardwareCoalescedEmerg | 1.3.6.1.4.1.12124.250.19.20.1 | There are hardware issues on a node | ||
| NTF hardwareCoalescedCrit | 1.3.6.1.4.1.12124.250.19.20.3 | There are hardware issues on a node | ||
| NTF hardwareCoalescedWarn | 1.3.6.1.4.1.12124.250.19.20.5 | There are hardware issues on a node | ||
| sensorCoalesced | 1.3.6.1.4.1.12124.250.19.50 | |||
| NTF sensorCoalescedEmerg | 1.3.6.1.4.1.12124.250.19.50.1 | There are sensor issues on a node | ||
| NTF sensorCoalescedCrit | 1.3.6.1.4.1.12124.250.19.50.3 | There are sensor issues on a node | ||
| NTF sensorCoalescedWarn | 1.3.6.1.4.1.12124.250.19.50.5 | There are sensor issues on a node | ||
| fanCoalesced | 1.3.6.1.4.1.12124.250.19.51 | |||
| NTF fanCoalescedEmerg | 1.3.6.1.4.1.12124.250.19.51.1 | There are fan issues on a node | ||
| NTF fanCoalescedCrit | 1.3.6.1.4.1.12124.250.19.51.3 | There are fan issues on a node | ||
| NTF fanCoalescedWarn | 1.3.6.1.4.1.12124.250.19.51.5 | There are fan issues on a node | ||
| tempCoalesced | 1.3.6.1.4.1.12124.250.19.52 | |||
| NTF tempCoalescedEmerg | 1.3.6.1.4.1.12124.250.19.52.1 | There are temp issues on a node | ||
| NTF tempCoalescedCrit | 1.3.6.1.4.1.12124.250.19.52.3 | There are temp issues on a node | ||
| NTF tempCoalescedWarn | 1.3.6.1.4.1.12124.250.19.52.5 | There are temp issues on a node | ||
| voltsCoalesced | 1.3.6.1.4.1.12124.250.19.53 | |||
| NTF voltsCoalescedEmerg | 1.3.6.1.4.1.12124.250.19.53.1 | There are voltage issues on a node | ||
| NTF voltsCoalescedCrit | 1.3.6.1.4.1.12124.250.19.53.3 | There are voltage issues on a node | ||
| NTF voltsCoalescedWarn | 1.3.6.1.4.1.12124.250.19.53.5 | There are voltage issues on a node | ||
| systemDiskTraps | 1.3.6.1.4.1.12124.250.20 | |||
| driveStatus | 1.3.6.1.4.1.12124.250.20.1 | |||
| NTF driveStatusInfo | 1.3.6.1.4.1.12124.250.20.1.1 | A node has detected a problem with a drive | ||
| NTF driveStatusCrit | 1.3.6.1.4.1.12124.250.20.1.3 | A node has detected a problem with a drive | ||
| NTF driveStatusWarn | 1.3.6.1.4.1.12124.250.20.1.5 | A node has detected a problem with a drive | ||
| bootDiskFail | 1.3.6.1.4.1.12124.250.20.2 | |||
| NTF bootDiskFailCrit | 1.3.6.1.4.1.12124.250.20.2.3 | Unhealthy boot disks, mirror is degraded. | ||
| NTF bootDiskFailWarn | 1.3.6.1.4.1.12124.250.20.2.5 | Unhealthy boot disks, mirror is degraded. | ||
| diskError | 1.3.6.1.4.1.12124.250.20.3 | |||
| NTF diskErrorWarn | 1.3.6.1.4.1.12124.250.20.3.3 | A node's disks are having problems | ||
| bootDiskMirrorReqMissing | 1.3.6.1.4.1.12124.250.20.4 | |||
| NTF bootdiskMirrorReqMissingCrit | 1.3.6.1.4.1.12124.250.20.4.3 | Error creating mirror on bootdisks. | ||
| diskErrorCoalesced | 1.3.6.1.4.1.12124.250.20.20 | |||
| NTF diskErrorCoalescedCrit | 1.3.6.1.4.1.12124.250.20.20.3 | A node's disks are having critical problems | ||
| NTF diskErrorCoalescedWarn | 1.3.6.1.4.1.12124.250.20.20.5 | A node's disks are having warning level problems | ||
| sensorTraps | 1.3.6.1.4.1.12124.250.21 | |||
| hwPwrSupply | 1.3.6.1.4.1.12124.250.21.1 | |||
| hwPwrSupplyOver | 1.3.6.1.4.1.12124.250.21.1.1 | |||
| NTF hwPwrSupplyOverCrit | 1.3.6.1.4.1.12124.250.21.1.1.3 | Power supply current over critical threshold | ||
| NTF hwPwrSupplyOverWarn | 1.3.6.1.4.1.12124.250.21.1.1.5 | Power supply current over warning threshold | ||
| hwPwrSupplyUnder | 1.3.6.1.4.1.12124.250.21.1.2 | |||
| NTF hwPwrSupplyUnderCrit | 1.3.6.1.4.1.12124.250.21.1.2.3 | Power supply current under critical threshold | ||
| NTF hwPwrSupplyUnderWarn | 1.3.6.1.4.1.12124.250.21.1.2.5 | Power supply current under warning threshold | ||
| hwFan | 1.3.6.1.4.1.12124.250.21.2 | |||
| hwFanOver | 1.3.6.1.4.1.12124.250.21.2.1 | |||
| NTF hwFanOverCrit | 1.3.6.1.4.1.12124.250.21.2.1.3 | A node's fan is over critical threshold | ||
| NTF hwFanOverWarn | 1.3.6.1.4.1.12124.250.21.2.1.5 | A node's fan is over warning threshold | ||
| NTF hwFanOverInfo | 1.3.6.1.4.1.12124.250.21.2.1.7 | A node's fan is over warning threshold | ||
| hwFanUnder | 1.3.6.1.4.1.12124.250.21.2.2 | |||
| NTF hwFanUnderCrit | 1.3.6.1.4.1.12124.250.21.2.2.3 | A node's fan is under critical threshold | ||
| NTF hwFanUnderWarn | 1.3.6.1.4.1.12124.250.21.2.2.5 | A node's fan is under warning threshold | ||
| NTF hwFanUnderInfo | 1.3.6.1.4.1.12124.250.21.2.2.7 | A node's fan is under warning threshold | ||
| NTF hwFanCrit | 1.3.6.1.4.1.12124.250.21.2.3 | A node's fan failed | ||
| NTF hwFanWarn | 1.3.6.1.4.1.12124.250.21.2.5 | A node's fan monitor is about to fail | ||
| hwVoltage | 1.3.6.1.4.1.12124.250.21.10 | |||
| hwVoltageOver | 1.3.6.1.4.1.12124.250.21.10.1 | |||
| NTF hwVoltageOverCrit | 1.3.6.1.4.1.12124.250.21.10.1.3 | A node's voltage is over critical threshold | ||
| NTF hwVoltageOverWarn | 1.3.6.1.4.1.12124.250.21.10.1.5 | A node's voltage is over warning threshold | ||
| NTF hwVoltageOverInfo | 1.3.6.1.4.1.12124.250.21.10.1.7 | A node's voltage is over a threshold | ||
| hwVoltageUnder | 1.3.6.1.4.1.12124.250.21.10.2 | |||
| NTF hwVoltageUnderCrit | 1.3.6.1.4.1.12124.250.21.10.2.3 | A node's voltage is under critical threshold | ||
| NTF hwVoltageUnderWarn | 1.3.6.1.4.1.12124.250.21.10.2.5 | A node's voltage is under warning threshold | ||
| NTF hwVoltageUnderInfo | 1.3.6.1.4.1.12124.250.21.10.2.7 | A node's voltage is under a threshold | ||
| hwTemp | 1.3.6.1.4.1.12124.250.21.11 | |||
| hwTempOver | 1.3.6.1.4.1.12124.250.21.11.1 | |||
| NTF hwTempOverEmerg | 1.3.6.1.4.1.12124.250.21.11.1.1 | A node's temperature is over emergency threshold | ||
| NTF hwTempOverCrit | 1.3.6.1.4.1.12124.250.21.11.1.3 | A node's temperature is over critical threshold | ||
| NTF hwTempOverWarn | 1.3.6.1.4.1.12124.250.21.11.1.5 | A node's temperature is over warning threshold | ||
| NTF hwTempOverInfo | 1.3.6.1.4.1.12124.250.21.11.1.7 | A node's temperature is over a threshold | ||
| hwTempUnder | 1.3.6.1.4.1.12124.250.21.11.2 | |||
| NTF hwTempUnderEmerg | 1.3.6.1.4.1.12124.250.21.11.2.1 | A node's temperature is under emergency threshold | ||
| NTF hwTempUnderCrit | 1.3.6.1.4.1.12124.250.21.11.2.3 | A node's temperature is under critical threshold | ||
| NTF hwTempUnderWarn | 1.3.6.1.4.1.12124.250.21.11.2.5 | A node's temperature is under warning threshold | ||
| NTF hwTempUnderInfo | 1.3.6.1.4.1.12124.250.21.11.2.7 | A node's temperature is under a threshold | ||
| hwPower | 1.3.6.1.4.1.12124.250.21.12 | |||
| NTF hwPowerCrit | 1.3.6.1.4.1.12124.250.21.12.3 | A node has a power supply problem | ||
| NTF hwPowerWarn | 1.3.6.1.4.1.12124.250.21.12.5 | A node has a power supply monitoring problem | ||
| hwMem | 1.3.6.1.4.1.12124.250.21.13 | |||
| NTF hwMemCrit | 1.3.6.1.4.1.12124.250.21.13.3 | A node is low on memory | ||
| hwCpuThrottle | 1.3.6.1.4.1.12124.250.21.14 | |||
| NTF hwCpuThrottleCrit | 1.3.6.1.4.1.12124.250.21.14.3 | A node is at 100% CPU utilization | ||
| sensorMonitor | 1.3.6.1.4.1.12124.250.21.15 | |||
| NTF sensorMonitorCrit | 1.3.6.1.4.1.12124.250.21.15.1 | A sensor failed | ||
| NTF sensorMonitorWarn | 1.3.6.1.4.1.12124.250.21.15.2 | A sensor is failing | ||
| hwCurrent | 1.3.6.1.4.1.12124.250.21.16 | |||
| hwCurrentOver | 1.3.6.1.4.1.12124.250.21.16.1 | |||
| NTF hwCurrentOverEmerg | 1.3.6.1.4.1.12124.250.21.16.1.1 | A node's current is over emergency threshold | ||
| NTF hwCurrentOverCrit | 1.3.6.1.4.1.12124.250.21.16.1.3 | A node's current is over critical threshold | ||
| NTF hwCurrentOverWarn | 1.3.6.1.4.1.12124.250.21.16.1.5 | A node's current is over warning threshold | ||
| NTF hwCurrentOverInfo | 1.3.6.1.4.1.12124.250.21.16.1.7 | A node's current is over a threshold | ||
| hwCurrentUnder | 1.3.6.1.4.1.12124.250.21.16.2 | |||
| NTF hwCurrentUnderEmerg | 1.3.6.1.4.1.12124.250.21.16.2.1 | A node's current is under emergency threshold | ||
| NTF hwCurrentUnderCrit | 1.3.6.1.4.1.12124.250.21.16.2.3 | A node's current is under critical threshold | ||
| NTF hwCurrentUnderWarn | 1.3.6.1.4.1.12124.250.21.16.2.5 | A node's current is under warning threshold | ||
| NTF hwCurrentUnderInfo | 1.3.6.1.4.1.12124.250.21.16.2.7 | A node's current is under a threshold | ||
| storageTransportTraps | 1.3.6.1.4.1.12124.250.22 | |||
| sasPhyError | 1.3.6.1.4.1.12124.250.22.1 | |||
| NTF sasPhyErrorExpanderWarn | 1.3.6.1.4.1.12124.250.22.1.5 | A SAS PHY error was detected in the expander. | ||
| NTF sasPhyErrorControllerWarn | 1.3.6.1.4.1.12124.250.22.1.7 | A SAS PHY error was detected in the controller. | ||
| storageTransportCoalesced | 1.3.6.1.4.1.12124.250.22.2 | |||
| NTF storageTransportCoalescedEmerg | 1.3.6.1.4.1.12124.250.22.2.1 | There are storage transport issues on a node | ||
| NTF storageCoalescedCrit | 1.3.6.1.4.1.12124.250.22.2.3 | There are storage transport issues on a node | ||
| NTF storageCoalescedWarn | 1.3.6.1.4.1.12124.250.22.2.5 | There are storage transport issues on a node | ||
| cloudPoolsTraps | 1.3.6.1.4.1.12124.250.23 | |||
| cloudpoolNetworkError | 1.3.6.1.4.1.12124.250.23.1 | |||
| NTF cloudpoolNetworkErrorCrit | 1.3.6.1.4.1.12124.250.23.1.3 | CloudPools network issues | ||
| cloudpoolAuthenticationError | 1.3.6.1.4.1.12124.250.23.2 | |||
| NTF cloudpoolAuthenticationErrorCrit | 1.3.6.1.4.1.12124.250.23.2.3 | CloudPools authentication issues | ||
| cloudpoolAuthorizationError | 1.3.6.1.4.1.12124.250.23.3 | |||
| NTF cloudpoolAuthorizationErrorCrit | 1.3.6.1.4.1.12124.250.23.3.3 | CloudPools authorization issues | ||
| cloudpoolBucketNotFoundError | 1.3.6.1.4.1.12124.250.23.4 | |||
| NTF cloudpoolBucketNotFoundErrorCrit | 1.3.6.1.4.1.12124.250.23.4.3 | CloudPools bucket not found issues | ||
| cloudpoolObjectNotFoundError | 1.3.6.1.4.1.12124.250.23.5 | |||
| NTF cloudpoolObjectNotFoundErrorCrit | 1.3.6.1.4.1.12124.250.23.5.3 | CloudPools Object not found issues | ||
| cloudpoolDataCorruptionIntegrityError | 1.3.6.1.4.1.12124.250.23.6 | |||
| NTF cloudpoolDataCorruptionIntegrityErrorEmerg | 1.3.6.1.4.1.12124.250.23.6.1 | CloudPools data corruption integrity emergency issues | ||
| cloudpoolNoUsableAccountFoundError | 1.3.6.1.4.1.12124.250.23.7 | |||
| NTF cloudpoolNoUsableAccountFoundErrorCrit | 1.3.6.1.4.1.12124.250.23.7.3 | CloudPools no usable account found for the policy, cloudpool | ||
| cloudpoolCertificateError | 1.3.6.1.4.1.12124.250.23.8 | |||
| NTF cloudpoolCertificateErrorCrit | 1.3.6.1.4.1.12124.250.23.8.3 | CloudPools Certificate issues | ||
| upgradeTraps | 1.3.6.1.4.1.12124.250.24 | |||
| upgradeStart | 1.3.6.1.4.1.12124.250.24.1 | |||
| NTF upgradeStartInfo | 1.3.6.1.4.1.12124.250.24.1.7 | An upgrade or rollback has been started. | ||
| upgradeFinish | 1.3.6.1.4.1.12124.250.24.2 | |||
| NTF upgradeFinishInfo | 1.3.6.1.4.1.12124.250.24.2.7 | An upgrade or rollback has finished. | ||
| upgradeClusterEvent | 1.3.6.1.4.1.12124.250.24.3 | |||
| NTF upgradeClusterEventCrit | 1.3.6.1.4.1.12124.250.24.3.3 | Upgrade cluster event. | ||
| NTF upgradeClusterEventWarn | 1.3.6.1.4.1.12124.250.24.3.5 | Upgrade cluster event. | ||
| NTF upgradeClusterEventInfo | 1.3.6.1.4.1.12124.250.24.3.7 | Upgrade cluster event. | ||
| upgradeNodeEvent | 1.3.6.1.4.1.12124.250.24.4 | |||
| NTF upgradeNodeEventCrit | 1.3.6.1.4.1.12124.250.24.4.3 | Upgrade node event. | ||
| NTF upgradeNodeEventWarn | 1.3.6.1.4.1.12124.250.24.4.5 | Upgrade node event. | ||
| NTF upgradeNodeEventInfo | 1.3.6.1.4.1.12124.250.24.4.7 | Upgrade node event. | ||
| upgradeRollbackStart | 1.3.6.1.4.1.12124.250.24.5 | |||
| NTF upgradeRollbackStartInfo | 1.3.6.1.4.1.12124.250.24.5.7 | Upgrade rollback start. | ||
| variables | 1.3.6.1.4.1.12124.250.50 | |||
| I32 nodeIdentifier | 1.3.6.1.4.1.12124.250.50.1 | Integer32 | accessible-for-notify | The Logical Node Number of the node referenced in the notification. |
| I32 measuredValue | 1.3.6.1.4.1.12124.250.50.2 | Integer32 | accessible-for-notify | The measured value that triggered the event |
| OCT units | 1.3.6.1.4.1.12124.250.50.3 | OCTET STRING | accessible-for-notify | The units of the measurement |
| OID oid | 1.3.6.1.4.1.12124.250.50.4 | OBJECT IDENTIFIER | accessible-for-notify | The OID of the sensor reporting a problem |
| I32 bay | 1.3.6.1.4.1.12124.250.50.5 | Integer32 | accessible-for-notify | Drive bay number |
| OCT ifName | 1.3.6.1.4.1.12124.250.50.6 | OCTET STRING | accessible-for-notify | Interface name |
| I32 phy | 1.3.6.1.4.1.12124.250.50.7 | Integer32 | accessible-for-notify | PHY connection |
| OCT errorMessage | 1.3.6.1.4.1.12124.250.50.8 | OCTET STRING | accessible-for-notify | Error message |
| I32 errno | 1.3.6.1.4.1.12124.250.50.9 | Integer32 | accessible-for-notify | Error number |
| OCT stringArg | 1.3.6.1.4.1.12124.250.50.10 | OCTET STRING | accessible-for-notify | A trap-related string argument. |
| OCT message | 1.3.6.1.4.1.12124.250.50.11 | OCTET STRING | accessible-for-notify | A trap-related message string. |
| C64 i64Arg | 1.3.6.1.4.1.12124.250.50.12 | Counter64 | accessible-for-notify | Error number |
| I32 i32Arg | 1.3.6.1.4.1.12124.250.50.13 | Integer32 | accessible-for-notify | Integer argument |
| OCT measuredValueStr | 1.3.6.1.4.1.12124.250.50.14 | OCTET STRING | accessible-for-notify | The measured value that triggered the event represented as string |
| OCT instanceIdentifier | 1.3.6.1.4.1.12124.250.50.15 | OCTET STRING | accessible-for-notify | Instance ID of event generating the trap |
| I32 deviceIdentifier | 1.3.6.1.4.1.12124.250.50.16 | Integer32 | accessible-for-notify | The Device Node Number of the node referenced in the notification. |
| trapConformance | 1.3.6.1.4.1.12124.250.51 | |||
| groupStateTrapsGroup | 1.3.6.1.4.1.12124.250.51.1 | Collection of traps for group state. | ||
| filesystemTrapsGroup | 1.3.6.1.4.1.12124.250.51.11 | Collection of filesystem traps. | ||
| smartQuotaTrapsGroup | 1.3.6.1.4.1.12124.250.51.12 | Collection of smartQuota traps. | ||
| snapshotTrapsGroup | 1.3.6.1.4.1.12124.250.51.13 | Collection of snapshot traps. | ||
| syncIQTrapsGroup | 1.3.6.1.4.1.12124.250.51.14 | Collection of syncIQ traps. | ||
| softwareTrapsGroup | 1.3.6.1.4.1.12124.250.51.15 | Collection of software traps. | ||
| avscanTrapsGroup | 1.3.6.1.4.1.12124.250.51.16 | Collection of avscan traps. | ||
| netProtoTrapsGroup | 1.3.6.1.4.1.12124.250.51.17 | Collection of net protocol traps. | ||
| networkingTrapsGroup | 1.3.6.1.4.1.12124.250.51.18 | Collection of networking traps. | ||
| hardwareTrapsGroup | 1.3.6.1.4.1.12124.250.51.19 | Collection of sensor traps. | ||
| systemDiskTrapsGroup | 1.3.6.1.4.1.12124.250.51.20 | Collection of system disk traps. | ||
| sensorTrapsGroup | 1.3.6.1.4.1.12124.250.51.21 | Collection of sensor traps. | ||
| storageTransportTrapsGroup | 1.3.6.1.4.1.12124.250.51.22 | Collection of storage transport traps. | ||
| cloudPoolsTrapsGroup | 1.3.6.1.4.1.12124.250.51.23 | Collection of cloud pools traps. | ||
| upgradeTrapsGroup | 1.3.6.1.4.1.12124.250.51.24 | Collection of upgrade traps. | ||
| variablesGroup | 1.3.6.1.4.1.12124.250.51.50 | Collection of variable traps. | ||
| trapCompliance | 1.3.6.1.4.1.12124.250.52 | |||
| trapGroupCompliance | 1.3.6.1.4.1.12124.250.52.1 | Compliance statement for the Isilon traps. |
RFC description
Traps and notifications for Isilon Systems OneFS storage platform including filesystem, snapshot, and hardware events.
Start monitoring Isilon (EMC/Dell) OneFS scale-out NAS cluster (trap notifications) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.