| OID symbolic | OID numeric | Type | Access | Description |
| codex | 1.3.6.1.4.1.449 | | | |
| cdxProductSpecific | 1.3.6.1.4.1.449.2 | | | |
| cdx6500 | 1.3.6.1.4.1.449.2.1 | | | |
| cdx6500Configuration | 1.3.6.1.4.1.449.2.1.2 | | | |
| cdx6500CfgProtocolGroup | 1.3.6.1.4.1.449.2.1.2.1 | | | |
| cdx6500PCTPortProtocolGroup | 1.3.6.1.4.1.449.2.1.2.1.1 | | | |
| cdx6500PPCTIBM2260PortTable | 1.3.6.1.4.1.449.2.1.2.1.1.20 | | not-accessible | A list of IBM2260 Port configuration entries. |
| cdx6500PPCTIBM2260PortEntry | 1.3.6.1.4.1.449.2.1.2.1.1.20.1 | | not-accessible | An IBM2260 Configuration Table entry. Each entry
contains the configuration parameters for a single
IBM2260 port. |
| INT cdx6500IBM2260CfgPortNumber | 1.3.6.1.4.1.449.2.1.2.1.1.20.1.1 | INTEGER | read-only | The port number corresponding to this port. |
| INT cdx6500IBM2260CfgPadType | 1.3.6.1.4.1.449.2.1.2.1.1.20.1.2 | INTEGER | read-only | Indicates whether the port is functioning as a Terminal
PAD (TPAD) or a Host PAD (HPAD). |
| INT cdx6500IBM2260CfgPortSpeed | 1.3.6.1.4.1.449.2.1.2.1.1.20.1.3 | INTEGER | read-only | This is the speed of the port in bits per second, when using
internal clocking. |
| INT cdx6500IBM2260CfgConnType | 1.3.6.1.4.1.449.2.1.2.1.1.20.1.4 | INTEGER | read-only | Specify the control signal handshake required for a
connection to be made to this port:
simp - simple, no control signals required.
simpa - CTS follows RTS, but no control signals required. |
| INT cdx6500IBM2260CfgNumDevice | 1.3.6.1.4.1.449.2.1.2.1.1.20.1.5 | INTEGER | read-only | Specifies the number of IBM2260 stations on this line. |
| INT cdx6500IBM2260CfgServiceTimer | 1.3.6.1.4.1.449.2.1.2.1.1.20.1.6 | INTEGER | read-only | The Service Timer specifies the interval of time in
seconds between periodic servicing. Such servicing
includes intervals between attempts to establish network
connections, intervals between attempts in TPAD to poll
terminals that previously failed to respond, and in HPAD
this timer is also used to detect host inactivity
(i.e. when the host stops polling the station(s)). |
| INT cdx6500IBM2260CfgThreshCtr | 1.3.6.1.4.1.449.2.1.2.1.1.20.1.7 | INTEGER | read-only | Indicates number of consecutive errors that can occur
before a station is considered down. |
| INT cdx6500IBM2260CfgRespTimeout | 1.3.6.1.4.1.449.2.1.2.1.1.20.1.8 | INTEGER | read-only | Specifies the amount of time in msec the PAD allows
a terminal, printer or host to respond. As a result,
the TPAD may re-transmit the previous message or abort
the current procedure.
The HPAD aborts the current procedure as though EOT
was received, allowing this HPAD station to disconnect
it's SVC if the host malfunctions. An HPAD with
a response timeout shorter than the hosts ability to respond
may result in Inbound Errors. |
| STR cdx6500IBM2260CfgPortSubAddr | 1.3.6.1.4.1.449.2.1.2.1.1.20.1.9 | DisplayString | read-only | Calls addressed to this node and with this subaddress
will be routed to this port. |
| STR cdx6500IBM2260CfgPortOpt | 1.3.6.1.4.1.449.2.1.2.1.1.20.1.10 | DisplayString | read-only | Select options on this IBM2260 port as follows:
NONE - No option specified
ORG - Originate calls from this port
ACK - DSP End-to-End Acknowledgements are to be used
Any combination of above specified by summing (e.g. ORG+ACK). |
| STR cdx6500IBM2260CfgRestConnDest | 1.3.6.1.4.1.449.2.1.2.1.1.20.1.11 | DisplayString | read-only | All calls originating from this port will be routed to the
destination specified in this parameter, irrespective of route
selection table entries.
For example, to route calls to port 1, use P1. To route
calls to port 2, station 4, use P2S4.
Blank this field to disable this function. |
| INT cdx6500IBM2260CfgBillRec | 1.3.6.1.4.1.449.2.1.2.1.1.20.1.12 | INTEGER | read-only | This controls whether billing (accounting) records will be
created for calls on this port. |
| INT cdx6500IBM2260CfgElectricalInterfaceType | 1.3.6.1.4.1.449.2.1.2.1.1.20.1.13 | INTEGER | read-only | Specify the Electrical Interface Type:
V.24 - V.24 Electrical Interface Type
V.35 - V.35 Electrical Interface Type
V.36 - V.36 Electrical Interface Type
X.21 - X.21 Electrical Interface Type
Note: Changing this parameter requires manual settings on SWITCH1:
Interface SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8
V.24 ON ON ON ON ON OFF OFF OFF
V.35,V.36,X.21 OFF OFF OFF OFF OFF ON ON ON |
| INT cdx6500IBM2260CfgV24ElectricalInterfaceOption | 1.3.6.1.4.1.449.2.1.2.1.1.20.1.14 | INTEGER | read-only | Specify the Pin 22 option:
RI - V.24 uses Pin 22 for Ring Indicator output signal
TM - V.24 uses Pin 22 for Test Mode input signal |
| INT cdx6500IBM2260CfgHighSpeedElectricalInterfaceOption | 1.3.6.1.4.1.449.2.1.2.1.1.20.1.15 | INTEGER | read-only | Specify the cable type:
NONE - V.35/V.36/X.21 DCE with straight through cable
XOVER - V.35/V.36/X.21 DCE with crossover adapter cable |
| cdx6500PCTStationProtocolGroup | 1.3.6.1.4.1.449.2.1.2.1.3 | | | |
| cdx6500SPCTIBM2260StationTable | 1.3.6.1.4.1.449.2.1.2.1.3.6 | | not-accessible | All of the configuration parameters relevant
to the IBM2260 Station table. |
| cdx6500SPCTIBM2260StationEntry | 1.3.6.1.4.1.449.2.1.2.1.3.6.1 | | not-accessible | A row of IBM2260 station configuration parameters. |
| INT cdx6500IBM2260sCfgPortNum | 1.3.6.1.4.1.449.2.1.2.1.3.6.1.1 | INTEGER | read-only | Port number. |
| INT cdx6500IBM2260sCfgStationNum | 1.3.6.1.4.1.449.2.1.2.1.3.6.1.2 | INTEGER | read-only | Station number. |
| INT cdx6500IBM2260sType | 1.3.6.1.4.1.449.2.1.2.1.3.6.1.3 | INTEGER | read-only | single - configures a single station addressable by
the ADDR1-ADDR2 address pair.
group - configures a group of stations addressable
by the ADDR1 address character, but ADDR2 is
assumed to be 40H, 41H, 42H and 43H.
This type is intended for support of DataTroll
devices.
NOTE: `group' Station should not be used when the
BSC3270-IBM2260 protocol Interoperation is being used. |
| STR cdx6500IBM2260sStationAddr1 | 1.3.6.1.4.1.449.2.1.2.1.3.6.1.4 | DisplayString | read-only | This is the first byte of this Station's address.
The Station address consists of two hexadecimal digits.
The valid range for a digit is: 20-7F; |
| STR cdx6500IBM2260sStationAddr2 | 1.3.6.1.4.1.449.2.1.2.1.3.6.1.5 | DisplayString | read-only | This is the second byte of this Station's address.
The Station address consists of two hexadecimal digits.
The valid range for a digit is: 20-7F |
| STR cdx6500IBM2260sCallMnem | 1.3.6.1.4.1.449.2.1.2.1.3.6.1.6 | DisplayString | read-only | This mnemonic name is used if this port is
configured for originating connection requests. |
| INT cdx6500IBM2260sStationEnable | 1.3.6.1.4.1.449.2.1.2.1.3.6.1.7 | INTEGER | read-only | This parameter is used to disable/enable a station. |
| cdx6500Statistics | 1.3.6.1.4.1.449.2.1.3 | | | |
| cdx6500StatProtocolGroup | 1.3.6.1.4.1.449.2.1.3.1 | | | |
| cdx6500PSTPortProtocolGroup | 1.3.6.1.4.1.449.2.1.3.1.1 | | | |
| cdx6500PPSTIBM2260PortTable | 1.3.6.1.4.1.449.2.1.3.1.1.19 | | not-accessible | A list of IBM2260 Port statistics. |
| cdx6500PPSTIBM2260PortEntry | 1.3.6.1.4.1.449.2.1.3.1.1.19.1 | | not-accessible | An IBM2260 Statistics Table entry. Each entry
contains the statistics for a single IBM2260 port. |
| INT cdx6500IBM2260StatPortNumber | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.1 | INTEGER | read-only | Physical port number |
| STR cdx6500IBM2260StatPortStatus | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.2 | DisplayString | read-only | Operational Status of the port.
The different operational statuses are:
UP : At least 1 station is responding to polls.
DOWN : None of the stations are responding to polls.
DISABLED : The port is disabled by the user. |
| STR cdx6500IBM2260StatPortState | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.3 | DisplayString | read-only | Current State of this port. |
| INT cdx6500IBM2260StatPortSpeed | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.4 | INTEGER | read-only | The measured port speed in bits per second. |
| INT cdx6500IBM2260StatPortUtilin | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.5 | INTEGER | read-only | The amount of the port's bandwidth that is being utilized;
because IBM2260 is a half-duplex protocol the utilization
is calculated as the sum of the receive and transmit
utilization. |
| INT cdx6500IBM2260StatPortUtilOut | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.6 | INTEGER | read-only | The amount of the port's bandwidth that is being utilized;
because IBM2260 is a half-duplex protocol the utilization
is calculated as the sum of the receive and transmit
utilization. |
| INT cdx6500IBM2260StatParityErrors | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.7 | INTEGER | read-only | The number of character parity errors counted by the I/O
driver. |
| INT cdx6500IBM2260StatOverrunErrors | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.8 | INTEGER | read-only | The number of received character overruns counted
by the I/O driver. |
| INT cdx6500IBM2260StatFramingErrors | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.9 | INTEGER | read-only | The number of asynchronous chracters received which violated
the character framing of start and stop bits.
Note, this statistic is only valid if the port is configured
for ASYNC line interface. |
| INT cdx6500IBM2260StatBCCErrors | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.10 | INTEGER | read-only | The number of BCC errors counted by the I/O driver. |
| INT cdx6500IBM2260StatNoResponse | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.11 | INTEGER | read-only | The number of times the response timer has expired. |
| INT cdx6500IBM2260StatCharInTotal | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.12 | INTEGER | read-only | Total number of chracters received to present. |
| INT cdx6500IBM2260StatCharOutTotal | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.13 | INTEGER | read-only | Total number of chracters transmitted to present. |
| INT cdx6500IBM2260StatCharInSecond | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.14 | INTEGER | read-only | Average number of characters received to present. |
| INT cdx6500IBM2260StatCharOutSecond | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.15 | INTEGER | read-only | Average number of characters transmitted to present. |
| INT cdx6500IBM2260StatPosAckIn | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.16 | INTEGER | read-only | Number of ACKs received. |
| INT cdx6500IBM2260StatPosAckOut | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.17 | INTEGER | read-only | Number of ACKs transmitted. |
| INT cdx6500IBM2260StatNegAckIn | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.18 | INTEGER | read-only | Number of NAKs received. |
| INT cdx6500IBM2260StatNegAckOut | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.19 | INTEGER | read-only | Number of NAKs transmitted. |
| INT cdx6500IBM2260StatMsgRetran | 1.3.6.1.4.1.449.2.1.3.1.1.19.1.20 | INTEGER | read-only | Number of messages retransmitted due to NAKs or timeouts
to present. |
| cdx6500PSTStationProtocolGroup | 1.3.6.1.4.1.449.2.1.3.1.3 | | | |
| cdx6500Controls | 1.3.6.1.4.1.449.2.1.4 | | | |