IBM2260-OPT-MIB :: cdx6500IBM2260CfgRestConnDest

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › IBM2260-OPT-MIB › cdx6500IBM2260CfgRestConnDest

cdx6500IBM2260CfgRestConnDest

Module: IBM2260-OPT-MIB

OID (symbolic): IBM2260-OPT-MIB::cdx6500IBM2260CfgRestConnDest

OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.1.20.1.11

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: All calls originating from this port will be routed to the destination specified in this parameter, irrespective of route selection table entries. For example, to route calls to port 1, use P1. To route calls to port 2, station 4, use P2S4. Blank this field to disable this function.

What is cdx6500IBM2260CfgRestConnDest?

Forces all calls originating from this port to a fixed destination (for example P1 for port 1, or P2S4 for port 2 station 4), overriding the normal route-selection table; leaving it blank disables the override.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.20.1.11
snmpwalk -v2c -c public <target> IBM2260-OPT-MIB::cdx6500IBM2260CfgRestConnDest

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.20.1.11.1
snmpget -v2c -c public <target> IBM2260-OPT-MIB::cdx6500IBM2260CfgRestConnDest.1

Start monitoring IBM 2260 legacy terminal/network device (cdx6500-derived port/station config) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the IBM2260-OPT-MIB::cdx6500IBM2260CfgRestConnDest OID value, configure state conditions and alerts, and monitor any IBM 2260 legacy terminal/network device (cdx6500-derived port/station config) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.449codexALC-OPT-MIB
1.3.6.1.4.1.449.2cdxProductSpecificALC-OPT-MIB
1.3.6.1.4.1.449.2.1cdx6500ALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2cdx6500ConfigurationALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1cdx6500CfgProtocolGroupALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1cdx6500PCTPortProtocolGroupALC-OPT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.449.2.1.2.1.1.20cdx6500PPCTIBM2260PortTableIBM2260-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1.20.1cdx6500PPCTIBM2260PortEntryIBM2260-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1.20.1.11cdx6500IBM2260CfgRestConnDestIBM2260-OPT-MIB