| OID symbolic | OID numeric | Type | Access | Description |
| vdsl2Priv | 1.3.6.1.4.1.2011.6.115.1.7 | | | This MIB is used for defining Huawei's vdsl2 priv management MIB objects. |
| vdsl2Test | 1.3.6.1.4.1.2011.6.115.1.7.1 | | | |
| vdsl2SeltTestTable | 1.3.6.1.4.1.2011.6.115.1.7.1.1 | | not-accessible | This table contains the VDSL SELT configuration, SELT result, SELT data. The index of this table is ifIndex. |
| vdsl2SeltTestEntry | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1 | | not-accessible | This table contains the VDSL SELT configuration, SELT result, SELT data. The index of this entry is ifIndex. |
| VSD vdsl2SeltTestOperType | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.1 | VSDLSELTOPERTYPE | read-write | This object is used to start the VDSL SELT. Only the start of the SELT is supported current. The stop of the SELT is not supported. |
| VSD vdsl2SeltTestOperResult | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.2 | VSDLSELTOPERRESULT | accessible-for-notify | Selt test operation result. |
| I32 vdsl2SeltTestResultNo | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.3 | Integer32 | accessible-for-notify | Selt test result serial number. |
| VSD vdsl2SeltTestResultLastFlag | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.4 | VSDLSELTRESULTLASTFLAG | accessible-for-notify | Last package flag for test result. |
| OCT vdsl2SeltTestResult | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.5 | OCTET STRING | accessible-for-notify | Selt test result data. |
| I32 vdsl2SeltTestParamLoopLength | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.6 | Integer32 | read-only | Selt test parameter Loop Length. |
| VSD vdsl2SeltTestParamLoopTermin | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.7 | VSDLSELTPARAMLOOPTERMIN | read-only | Selt test parameter Loop Termination. |
| NUM vdsl2SeltTestParamLoopGauge | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.8 | VSDLSELTPARAMLOOPGAUGE | read-write | Selt test parameter Loop Gauge. |
| I32 vdsl2SeltTestParamUpShnCap | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.9 | Integer32 | read-only | Selt test parameter Upstream Shannon Capacity. |
| I32 vdsl2SeltTestParamDwnShnCap | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.10 | Integer32 | read-only | Selt test parameter Downstream Shannon Capacity. |
| OCT vdsl2SeltTestParamInbandNoise | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.11 | OCTET STRING | read-only | Selt test parameter Inband Noise
4096 values that indicate inband noise in DB/Hz,
covering VDSL bands, from 0 to 30 MHz. |
| OCT vdsl2SeltTestParamTerminResp | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.12 | OCTET STRING | read-only | Selt test parameter Termination Response
180 values that indicate termination response magnitude from 0 to 18 kft. |
| OCT vdsl2SeltTestParamUpMgnAtRate | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.13 | OCTET STRING | read-only | Selt test parameter Upstream Rate vs. Margin
This value is a measure of the quality of your upstream data
signal relative to the noise on the line. Hundreds of values that
indicate SNR margin in DB/Hz at a particular bit rate are provided,
at a certain increments, up to 30 Mbps. This information may be plotted
with the bit rate on the X-axis and the SNR margin on the Y-axis. |
| OCT vdsl2SeltTestParamDwnMgnAtRate | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.14 | OCTET STRING | read-only | Selt test parameter Downstream Rate vs. Margin
This value is a measure of the quality of your downstream data
signal relative to the noise on the line. Hundreds of values that
indicate SNR margin in DB/Hz at a particular bit rate are provided,
at a certain increments, up to 30 Mbps. This information may be plotted
with the bit rate on the X-axis and the SNR margin on the Y-axis. |
| OCT vdsl2SeltTestParamUpRateAtMgn | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.15 | OCTET STRING | read-only | Selt test parameter Upstream Margin vs. Rate |
| OCT vdsl2SeltTestParamDwnRateAtMgn | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.16 | OCTET STRING | read-only | Selt test parameter Downstream Margin vs. Rate |
| I32 hwvdsl2SeltTestParamAttnAt180KHZ | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.65535 | Integer32 | read-only | Selt test parameter AttnAt180KHZ.
It ranges from -950 to 0 (physical values are -95 to 0 dB).
The invalid value is -1. If no SELT is performed, no SELT data is generated
because the SELT is incomplete, or no SELT data can be obtained from
the port because the SELT data is aged and cleared, the invalid value will be returned.
Unit: 0.1 dB |
| I32 hwvdsl2SeltTestParamAttnAt300KHZ | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.65536 | Integer32 | read-only | Selt test parameter AttnAt300KHZ.
It ranges from -950 to 0 (physical values are -95 to 0 dB).
The invalid value is -1. If no SELT is performed, no SELT data is generated
because the SELT is incomplete, or no SELT data can be obtained from
the port because the SELT data is aged and cleared, the invalid value will be returned.
Unit: 0.1 dB |
| OCT hwvdsl2SeltTestParamQSPsdValue | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.65537 | OCTET STRING | read-only | Selt test parameter QuietSignal PSD.
An array of 4096 16-bits values,
designed for supporting up to 4096 (downstream) sub-carriers.
It ranges from -150 to -40 units of 1dBm/Hz. |
| U32 hwvdsl2SeltTestParamUnCalibLineScale | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.65538 | Unsigned32 | read-only | The scale factor of uncalibrated echo response shall be coded as a 32 bit unsigned integer. |
| OCT hwvdsl2SeltTestParamUnCalibEchoRespRealSegment1 | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.65539 | OCTET STRING | read-only | The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a
scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index i ranging
from 0 to NSC-1, the subcarrier spacing, Df = 4.3125 kHz, and (NSC-1)*UER_G*Df is the
highest frequency supported by the SELT-PMD functionality. The UER granularity parameter,
UER_G, has two valid values: 1 and 2, indicating whether the measurements were performed using
a tone spacing of 4.3125 kHz or of 8.625 kHz. If the uncalibrated echo response is being reported
over a frequency range of 17.664 MHz or lower, UER_G shall be set to 1. If the uncalibrated echo
response is being reported over a frequency range that is greater than 17.664 MHz, UER_G shall be
set to 2.
The scale factor shall be coded as a 32-bit unsigned integer. Both a(i) and b(i) shall be coded as
32-bit 2's complement signed integers. The value of UER(i* UER_G*Df) shall be defined as:
UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31. In order to maximize precision, the scale factor
shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 2^31-1.
NOTE - This data format supports an UER(f) granularity of 2^(-31) and an UER(f) dynamic range of
approximately +6 dB to -186 dB, however it does not imply any future accuracy requirements.
An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is a special value. It indicates that no
measurement could be done for this subcarrier either because it is not supported by the SELT-PMD
function, or that the value is out of range to be represented. |
| OCT hwvdsl2SeltTestParamUnCalibEchoRespRealSegment2 | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.65540 | OCTET STRING | read-only | The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a
scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index i ranging
from 0 to NSC-1, the subcarrier spacing, Df = 4.3125 kHz, and (NSC-1)*UER_G*Df is the
highest frequency supported by the SELT-PMD functionality. The UER granularity parameter,
UER_G, has two valid values: 1 and 2, indicating whether the measurements were performed using
a tone spacing of 4.3125 kHz or of 8.625 kHz. If the uncalibrated echo response is being reported
over a frequency range of 17.664 MHz or lower, UER_G shall be set to 1. If the uncalibrated echo
response is being reported over a frequency range that is greater than 17.664 MHz, UER_G shall be
set to 2.
The scale factor shall be coded as a 32-bit unsigned integer. Both a(i) and b(i) shall be coded as
32-bit 2's complement signed integers. The value of UER(i* UER_G*Df) shall be defined as:
UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31. In order to maximize precision, the scale factor
shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 2^31-1.
NOTE - This data format supports an UER(f) granularity of 2^(-31) and an UER(f) dynamic range of
approximately +6 dB to -186 dB, however it does not imply any future accuracy requirements.
An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is a special value. It indicates that no
measurement could be done for this subcarrier either because it is not supported by the SELT-PMD
function, or that the value is out of range to be represented. |
| OCT hwvdsl2SeltTestParamUnCalibEchoRespImgSegment1 | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.65541 | OCTET STRING | read-only | The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a
scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index i ranging
from 0 to NSC-1, the subcarrier spacing, Df = 4.3125 kHz, and (NSC-1)*UER_G*Df is the
highest frequency supported by the SELT-PMD functionality. The UER granularity parameter,
UER_G, has two valid values: 1 and 2, indicating whether the measurements were performed using
a tone spacing of 4.3125 kHz or of 8.625 kHz. If the uncalibrated echo response is being reported
over a frequency range of 17.664 MHz or lower, UER_G shall be set to 1. If the uncalibrated echo
response is being reported over a frequency range that is greater than 17.664 MHz, UER_G shall be
set to 2.
The scale factor shall be coded as a 32-bit unsigned integer. Both a(i) and b(i) shall be coded as
32-bit 2's complement signed integers. The value of UER(i* UER_G*Df) shall be defined as:
UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31. In order to maximize precision, the scale factor
shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 2^31-1.
NOTE - This data format supports an UER(f) granularity of 2^(-31) and an UER(f) dynamic range of
approximately +6 dB to -186 dB, however it does not imply any future accuracy requirements.
An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is a special value. It indicates that no
measurement could be done for this subcarrier either because it is not supported by the SELT-PMD
function, or that the value is out of range to be represented. |
| OCT hwvdsl2SeltTestParamUnCalibEchoRespImgSegment2 | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.65542 | OCTET STRING | read-only | The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a
scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index i ranging
from 0 to NSC-1, the subcarrier spacing, Df = 4.3125 kHz, and (NSC-1)*UER_G*Df is the
highest frequency supported by the SELT-PMD functionality. The UER granularity parameter,
UER_G, has two valid values: 1 and 2, indicating whether the measurements were performed using
a tone spacing of 4.3125 kHz or of 8.625 kHz. If the uncalibrated echo response is being reported
over a frequency range of 17.664 MHz or lower, UER_G shall be set to 1. If the uncalibrated echo
response is being reported over a frequency range that is greater than 17.664 MHz, UER_G shall be
set to 2.
The scale factor shall be coded as a 32-bit unsigned integer. Both a(i) and b(i) shall be coded as
32-bit 2's complement signed integers. The value of UER(i* UER_G*Df) shall be defined as:
UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31. In order to maximize precision, the scale factor
shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 2^31-1.
NOTE - This data format supports an UER(f) granularity of 2^(-31) and an UER(f) dynamic range of
approximately +6 dB to -186 dB, however it does not imply any future accuracy requirements.
An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is a special value. It indicates that no
measurement could be done for this subcarrier either because it is not supported by the SELT-PMD
function, or that the value is out of range to be represented. |
| U32 hwvdsl2SeltTestParamQlnGroupSize | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.65548 | Unsigned32 | read-only | Number of QLN(quiet line noise) per group.
The scale value is 1 or 4294967295.4294967295 is invalid value. |
| INT hwvdsl2SeltTestParamQmeC | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.65549 | INTEGER | read-write | The status of QLN capture switch.
Options:
1. enable(1) - Enable QLN capture switch
2. disable(2) - Disable QLN capture switch
3. invalid(-1) - Invalid value |
| INT hwvdsl2SeltTestParamUmeC | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.65550 | INTEGER | read-write | The status of UER capture switch.
Options:
1. enable(1) - Enable UER capture switch
2. disable(2) - Disable UER capture switch
3. invalid(-1) - Invalid value |
| OCT hwvdsl2SeltTestParaVarUerC | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.65551 | OCTET STRING | read-only | The relative variance of the uncalibrated echo response REL_VAR_UER(i* UER_G *Df) shall be
represented as an 8-bit unsigned integer v(i), where i is the subcarrier index i = 0 to NSC-1. The
value of REL_VAR_UER(i* UER_G *Df) shall be defined as REL_VAR_UER(i* UER_G *Df) = 3 - v(i)/2 dB.
The number v(i) is an 8-bit unsigned integer in the range 0 to 254.
This data format supports a REL_VAR_UER(i) over a range from -124 dB to +3 dB for each carrier with a granularity from 0.5 dB.
Out of range values shall be clamped to the closest range bound.
The special value v(i) = 255 indicates that no measurement is available for that carrier.
Unit: 0.5dB |
| U32 hwvdsl2SeltTestParaUerMmdC | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.65552 | Unsigned32 | read-write | This parameter is the maximum allowed time for SELT uncalibrated echo response measurement,
between the time of the start command written by the SELT-PMD-ME, and the time the result is
available for read operation by SELT-PMD-ME.
It is configurable between 5 seconds and 240 seconds, in steps of 1 second, Invalid value is 0xff.
Unit: 1 second |
| U32 hwvdsl2SeltTestParaQlnMmdC | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.65553 | Unsigned32 | read-write | This parameter is the maximum allowed time for SELT quiet line noise measurement, between the
time of the start command written by the SELT-PMD-ME, and the time the result is available for
read operation by SELT-PMD-ME.
It is configurable between 1 second and 240 seconds, in steps of 1 second. Invalid value is 0xff.
Unit: 1 second |
| INT hwvdsl2SeltTestParaUerStatus | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.65554 | INTEGER | read-only | UerStatus.
Options:
1.off(1) - The status is off.
2.running(2) - The status is running.
3.completed(3) - The status is completed.
4.failed(4) - The status is failed. |
| INT hwvdsl2SeltTestParaQlnStatus | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.65555 | INTEGER | read-only | QlnStatus.
Options:
1.off(1) - The status is off.
2.running(2) - The status is running.
3.completed(3) - The status is completed.
4.failed(4) - The status is failed. |
| INT hwvdsl2SeltTestParamCalcEnable | 1.3.6.1.4.1.2011.6.115.1.7.1.1.1.65556 | INTEGER | read-write | The status of calculation switch.
Options:
1. enable(1) - Enable calculation switch
2. disable(2) - Disable calculation switch
3. invalid(-1) - Invalid value
Default: enable(1) |
| vdsl2SeltTestLevelTable | 1.3.6.1.4.1.2011.6.115.1.7.1.2 | | not-accessible | This table supports the configuration of vdsl selt level.
The indexes of this table are hwFrameIndex and hwSlotIndex. |
| vdsl2SeltTestLevelEntry | 1.3.6.1.4.1.2011.6.115.1.7.1.2.1 | | not-accessible | This table supports the configuration of vdsl selt level.
The indexes of this entry are hwFrameIndex and hwSlotIndex. |
| I32 hwvdsl2SeltLevel | 1.3.6.1.4.1.2011.6.115.1.7.1.2.1.1 | Integer32 | read-write | The level of vdsl SELT:
1 Level0;
2 Level1;
3 Level2;
4 Level3.
A special value of -1 indicates the level of vdsl SELT is invalid. |
| vdsl2SeltCalibrationTable | 1.3.6.1.4.1.2011.6.115.1.7.1.3 | | not-accessible | This table describes calibration data of selt test.
The index of this table is ifIndex. |
| vdsl2SeltCalibrationEntry | 1.3.6.1.4.1.2011.6.115.1.7.1.3.1 | | not-accessible | This table describes calibration data of selt test.
The index of this entry is ifIndex. |
| OCT vdsl2SeltCalibrationInvVendorId | 1.3.6.1.4.1.2011.6.115.1.7.1.3.1.1 | OCTET STRING | read-only | It consists of 8 binary octets, including a
provider code. |
| OCT vdsl2SeltCalibrationDataSegment1 | 1.3.6.1.4.1.2011.6.115.1.7.1.3.1.2 | OCTET STRING | read-only | The part 1 of selt calibration data.
The unit of selt calibration data is 0.00001. |
| OCT vdsl2SeltCalibrationDataSegment2 | 1.3.6.1.4.1.2011.6.115.1.7.1.3.1.3 | OCTET STRING | read-only | The part 2 of selt calibration data.
The unit of selt calibration data is 0.00001. |