All MIBs › HUAWEI-GONU-MIB
Organization: Huawei Technologies Co.,Ltd.
Last Updated: 2012-10-08
Category: Technology: EPON/PON, Vendor: Huawei
Description: Huawei GONU (GPON Optical Network Unit) MIB providing management objects for GPON ONU configuration, status, and upstream/downstream traffic statistics.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is HUAWEI-GONU-MIB?
HUAWEI-GONU-MIB is a Huawei GPON (Gigabit Passive Optical Network) MIB for managing the Optical Network Unit (ONU) side of the GPON NNI interface, part of Huawei's access/FTTx product line. It exposes GPON ONU configuration and operational data, including interface/port setup and upstream/downstream traffic statistics. Beyond configuration, it supports hardware and link status monitoring for the optical unit -- ONU operational/link state and traffic counters reveal optical-signal or provisioning problems, functioning similarly to interface uptime/traffic monitoring on a copper interface but for a fiber access endpoint. It complements Huawei's broader GPON/OLT MIB suite and likely depends on Huawei's common enterprise textual conventions rather than a public GPON standard. It is deployed on Huawei GPON ONU devices at the customer or aggregation edge in fiber access (FTTH/FTTB) networks managed by an ISP's NMS. Engineers can download the HUAWEI-GONU-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in HUAWEI-GONU-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Huawei GPON Optical Network Unit (ONU)
Monitoring Examples
No specific object or table names were supplied for this module in the source, so a concrete example cannot be grounded in real identifiers. Based on its stated purpose, an operator would typically poll ONU interface status and upstream/downstream traffic counters to confirm a given GPON ONU is registered and passing traffic normally, revealing a dropped optical link or abnormal traffic drop-off if counters stop incrementing.
What Can Be Monitored
- ONU interface/link status
- upstream traffic statistics
- downstream traffic statistics
- GPON NNI configuration state
This MIB depends on
Related MIBs
Imported Objects
From HC-PerfHist-TC-MIB
| HCPerfIntervalThreshold | |
| HCPerfTimeElapsed |
From HUAWEI-DEVICE-MIB
| hwConfigChangeIP | |
| hwFrameIndex | OBJECT-TYPE |
| hwPortIndex | OBJECT-TYPE |
| hwSlotIndex | OBJECT-TYPE |
From HUAWEI-MIB
| huaweiMgmt | OBJECT-IDENTITY |
From IF-MIB
| ifIndex | OBJECT-TYPE |
From SNMP-FRAMEWORK-MIB
| SnmpAdminString |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Counter32 | |
| Counter64 | |
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| Unsigned32 |
From SNMPv2-TC
| RowStatus | |
| TruthValue |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| hwGponMIB | 1.3.6.1.4.1.2011.5.104 | This MIB is used for defining GPON NNI MIB objects. GPON NNI refers to PON interface at ONU. | ||
| hwGponOnu | 1.3.6.1.4.1.2011.5.104.1 | |||
| hwGonuNotifications | 1.3.6.1.4.1.2011.5.104.1.0 | |||
| NTF hwGonuLinkLOSTrap | 1.3.6.1.4.1.2011.5.104.1.0.1 | This trap is sent when the LOS(Loss of Signal) alarm of GPON ONU occures. | ||
| NTF hwGonuLinkLOFTrap | 1.3.6.1.4.1.2011.5.104.1.0.2 | This trap is sent when the LOF(Loss of Frame) alarm of GPON ONU occures. | ||
| NTF hwGonuLinkSFTrap | 1.3.6.1.4.1.2011.5.104.1.0.3 | This trap is sent when the SF(Signal Fail) alarm of GPON ONU occures. | ||
| NTF hwGonuLinkSDTrap | 1.3.6.1.4.1.2011.5.104.1.0.4 | This trap is sent when the SD(Signal Degrade) alarm of GPON ONU occures. | ||
| NTF hwGonuLinkLCDGTrap | 1.3.6.1.4.1.2011.5.104.1.0.5 | This trap is sent when the LCDG(Loss of Channel Delineation for GEM) alarm of GPON ONU occures. | ||
| NTF hwGonuLinkRDITrap | 1.3.6.1.4.1.2011.5.104.1.0.6 | This trap is sent when the RDI(Remote Defect Indication) alarm of GPON ONU occures. | ||
| NTF hwGonuLinkSUFTrap | 1.3.6.1.4.1.2011.5.104.1.0.7 | This trap is sent when the SUF(Start Up Failure) alarm of GPON ONU occures. | ||
| NTF hwGonuLinkDACTTrap | 1.3.6.1.4.1.2011.5.104.1.0.8 | This trap is sent when the DACT(Deactivate (ONU-ID)) alarm of GPON ONU occures. | ||
| NTF hwGonuLinkDISTrap | 1.3.6.1.4.1.2011.5.104.1.0.9 | This trap is sent when the DIS(Disabled (ONU serial number)) alarm of GPON ONU occures. | ||
| NTF hwGonuLinkMISTrap | 1.3.6.1.4.1.2011.5.104.1.0.10 | This trap is sent when the MIS((link) Mismatch) alarm of GPON ONU occures. | ||
| NTF hwGonuLinkPEETrap | 1.3.6.1.4.1.2011.5.104.1.0.11 | This trap is sent when the PEE(Physical Equipment Error) alarm of GPON ONU occures. | ||
| NTF hwGonuLinkTFTrap | 1.3.6.1.4.1.2011.5.104.1.0.12 | This trap is sent when the TF(Transmitter Failure) alarm of GPON ONU occures. | ||
| NTF hwGonuLinkMEMTrap | 1.3.6.1.4.1.2011.5.104.1.0.13 | This trap is sent when the MEM(Message Error Message) alarm of GPON ONU occures. | ||
| NTF hwGonuLinkMISRestoreTrap | 1.3.6.1.4.1.2011.5.104.1.0.14 | This trap is sent when the link mismatch of ONT(MIS) recovers. | ||
| NTF hwGonuLinkPEERestoreTrap | 1.3.6.1.4.1.2011.5.104.1.0.15 | This trap is sent when the OLT recovers from the physical equipment error. | ||
| NTF hwGonuTempExceedThreAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.16 | This trap is sent when the temperature of GPON optical-module exceeded alarm threshold. | ||
| NTF hwGonuTempExceedThreRestoreAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.17 | This trap is sent when the temperature of GPON ONU's optical-module exceeded alarm threshold recoveres. | ||
| NTF hwGonuVoltExceedThreAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.18 | This trap is sent when the voltage of GPON ONU's optical-module exceeded alarm threshold. | ||
| NTF hwGonuVoltExceedThreRestoreAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.19 | This trap is sent when the voltage of GPON ONU's optical-module exceeded alarm threshold recoveres. | ||
| NTF hwGonuBiasExceedThreAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.20 | This trap is sent when the bias current of GPON ONU's optical module exceeded alarm threshold. | ||
| NTF hwGonuBiasExceedThreRestoreAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.21 | This trap is sent when the bias current of GPON ONU's optical module exceeded alarm threshold recoveres. | ||
| NTF hwGonuTxPowerExceedThreAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.22 | This trap is sent when the tx-power of GPON ONU's optical-module exceeded alarm threshold. | ||
| NTF hwGonuTxPowerExceedThreRestoreAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.23 | This trap is sent when the tx-power of GPON ONU's optical-module exceeded alarm threshold recoveres. | ||
| NTF hwGonuRxPowerExceedThreRestoreAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.24 | This trap is sent when the rx-power of GPON ONU's optical-module exceeded alarm threshold. | ||
| NTF hwGonuRxPowerExceedThreAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.25 | This trap is sent when the rx-power of GPON ONU's optical-module exceeded alarm threshold recoveres. | ||
| NTF hwGonuROGUEOntFailAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.26 | This trap is sent when the ONU's optical-module always send laser. | ||
| NTF hwGonuROGUEOntRestoreAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.27 | This trap is sent when the ONU's optical-module always send laser alarm recoveres. | ||
| NTF hwGponnniOntLinkLosAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.28 | This trap is sent when the fiber is broken or ONT can not receive any expected optical signals(LOS). | ||
| NTF hwGponnniOntLinkLofAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.29 | This trap is sent when the loss of frame (LOF) occurs at the ONT. | ||
| NTF hwGponnniOntLinkSfAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.30 | This trap is sent when the signal failed (SF) occurs at the ONT. | ||
| NTF hwGponnniOntLinkSdAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.31 | This trap is sent when the signal degrade (SD) occurs at the ONT. | ||
| NTF hwGponnniOntLinkLcdgFailAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.32 | This trap is sent when the loss of GEM channel delineation (LCDG) occurs at the ONT. | ||
| NTF hwGponnniOntLinkSufFailAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.33 | This trap is sent when the ranging of the ONT failure (SUF) occurs. | ||
| NTF hwGponnniOntLinkLosRestoreAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.34 | This trap is sent when the loss of signal (LOS) at the ONT recovers. | ||
| NTF hwGponnniOntLinkLofRestoreAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.35 | This trap is sent when the loss of frame (LOF) at the ONT recovers. | ||
| NTF hwGponnniOntLinkSfRestoreAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.36 | This trap is sent when the signal failure (SF) at the ONT recovers. | ||
| NTF hwGponnniOntLinkSdRestoreAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.37 | This trap is sent when the signal degrade (SD) at the ONT recovers. | ||
| NTF hwGponnniOntLinkLcdgRestoreAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.38 | This trap is sent when the loss of GEM channel delineation (LCDG) at the ONT recovers. | ||
| NTF hwGponnniOntLinkSufRestoreAlarmTrap | 1.3.6.1.4.1.2011.5.104.1.0.39 | This trap is sent when the ranging of ONT failure (SUF) recovers. | ||
| hwGonuStatus | 1.3.6.1.4.1.2011.5.104.1.1 | |||
| hwGonuStatusTable | 1.3.6.1.4.1.2011.5.104.1.1.1 | not-accessible | The table hwGonuStatusTable contains configuration and status parameters of the GPON ONU. The index of this table is ifIndex. | |
| hwGonuStatusEntry | 1.3.6.1.4.1.2011.5.104.1.1.1.1 | not-accessible | The table hwGonuStatusTable contains configuration and status parameters of the GPON ONU. The index of this entry is ifIndex. | |
| INT hwGonuLinkStatus | 1.3.6.1.4.1.2011.5.104.1.1.1.1.1 | INTEGER | read-only | The port link status, Options: 1.linkDown(1) -Link down 2.linkUp(2) -Link up |
| INT hwGonuRegStatus | 1.3.6.1.4.1.2011.5.104.1.1.1.1.2 | INTEGER | read-only | The port register status, Options: 1. registerPass(1) -The port is authenticated successfully 2. registerFail(2) -The port fails to be authenticated |
| U32 hwGonuRxSpeed | 1.3.6.1.4.1.2011.5.104.1.1.1.1.3 | Unsigned32 | read-only | The port down stream speed. Unit: kbps |
| U32 hwGonuTxSpeed | 1.3.6.1.4.1.2011.5.104.1.1.1.1.4 | Unsigned32 | read-only | The port up stream speed. Unit: kbps |
| U32 hwGonuRxBitErr | 1.3.6.1.4.1.2011.5.104.1.1.1.1.5 | Unsigned32 | read-only | The port down stream bit error ratio. Unit: bits/100ms |
| INT hwGonuPloamStates | 1.3.6.1.4.1.2011.5.104.1.1.1.1.6 | INTEGER | read-only | The gpon onu PLOAM states. Options: 1. initial(1) -Initial state 2. standby(2) -Standby state 3. serialNumber(3) -Serial_Number state 4. ranging(4) -Ranging state 5. operation(5) -Operation state 6. popUp(6) -POPUP state 7. emergencyStop(7) -Emergency Stop state |
| U32 hwGonuOmciPortID | 1.3.6.1.4.1.2011.5.104.1.1.1.1.7 | Unsigned32 | read-only | Indicates the ID of the GEM port corresponding to the OMCI. |
| I32 hwGonuTxPower | 1.3.6.1.4.1.2011.5.104.1.1.1.1.8 | Integer32 | read-only | The MDU TX power. Unit: 1/100 dBm |
| I32 hwGonuRxPower | 1.3.6.1.4.1.2011.5.104.1.1.1.1.9 | Integer32 | read-only | The MDU RX power. Unit: 1/100 dBm |
| I32 hwGonuTemperature | 1.3.6.1.4.1.2011.5.104.1.1.1.1.10 | Integer32 | read-only | The MDU Current Temperature. Unit: 1/100 degree centigrade |
| I32 hwGonuBiasCurrent | 1.3.6.1.4.1.2011.5.104.1.1.1.1.11 | Integer32 | read-only | The MDU Laser Bias Current. Unit: 1/100 mA |
| I32 hwGonuVoltage | 1.3.6.1.4.1.2011.5.104.1.1.1.1.12 | Integer32 | read-only | The MDU Voltage. Unit: 1/100 mV |
| INT hwGonuRogueOntState | 1.3.6.1.4.1.2011.5.104.1.1.1.1.13 | INTEGER | read-only | Indicates whether the optical port is shut down due to the continuous mode(rogue ONU). Options: 1. yes(1) - The optical port is shut down due to the continuous mode 2. no(2) - The optical port is shut down due to other reason 3. invalid(-1) - Invalid value |
| INT hwGonuOpticsModuleType | 1.3.6.1.4.1.2011.5.104.1.1.1.1.14 | INTEGER | read-only | This object indicates the type of the optical transceiver. Options: 1. unknown(1) - Unknow 2. gpon(2) - GPON 3. epon(3) - EPON 4. epon10g(4) - 10G EPON 5. gpon10g(5) - 10G GPON 6. wdmpon(6) - WDM PON 7. hybridpon(7)- Hybrid PON 8. gponepon(8) - GPON and EPON 9. invalid(-1) - Indicates that the query fails or no information is detected |
| INT hwGonuOpticsModuleSubType | 1.3.6.1.4.1.2011.5.104.1.1.1.1.15 | INTEGER | read-only | This object indicates the sub type of the optical transceiver. Options: 1.unknown(1) - Unknow 2.classbplus(101) - CLASS B+ 3.classcplus(102) - CLASS C+ 4.classb(103) - CLASS B 5.px20(201) - PX20 6.px20plus(202) - PX20+ 7.pr30(301) - PR30 8.pr20(302) - PR20 9.prx30(303) - PRX30 10.prx20(304) - PRX20 11.classbplusandpx20plus(701) - CLASS B+ and PX20+ 12.invalid(-1) - Indicates that the query fails or no information is detected |
| INT hwGonuOpticsModuleUsedType | 1.3.6.1.4.1.2011.5.104.1.1.1.1.16 | INTEGER | read-only | This object indicates the application scenario of the optical transceiver. Options: 1.unknown(1) - Unknow 2.olt(2) - OLT 3.onu(4) - ONU 4.invalid(-1) - Indicates that the query fails or no information is detected |
| INT hwGonuOpticsModuleEncapsulationType | 1.3.6.1.4.1.2011.5.104.1.1.1.1.17 | INTEGER | read-only | This object indicates the encapsulation information about the optical transceiver. Options: 1. unknown(1) - Unknown 2. sff2x5(2) - SFF 2x5 3. sff2x10(3) - SFF 2x10 4. sfp(4) - SFP 5. xfp(5) - XFP 6. lxfp(6) - LXFP 7. bosaonboard(7)- BOSA ON BOARD 8. invalid(-1) - Indicates that the query fails or no information is detected |
| hwGonuStatistics | 1.3.6.1.4.1.2011.5.104.1.2 | |||
| hwGonuStatisticsTable | 1.3.6.1.4.1.2011.5.104.1.2.1 | not-accessible | The table hwGonuStatisticsTable contains statistics of the GPON ONU GMAC. The index of this table is ifIndex. | |
| hwGonuStatisticsEntry | 1.3.6.1.4.1.2011.5.104.1.2.1.1 | not-accessible | The table hwGonuStatisticsTable contains statistics of the GPON ONU GMAC. The index of this entry is ifIndex. | |
| C32 hwGonuTxOmciCellsCnt | 1.3.6.1.4.1.2011.5.104.1.2.1.1.1 | Counter32 | read-only | The port transmit OMCI cells count. |
| C32 hwGonuRxOmciCellsCnt | 1.3.6.1.4.1.2011.5.104.1.2.1.1.2 | Counter32 | read-only | The port receive OMCI cells count. |
| C32 hwGonuTxEthFramesCnt | 1.3.6.1.4.1.2011.5.104.1.2.1.1.3 | Counter32 | read-only | The port transmit ethernet frames count. |
| C32 hwGonuRxEthFramesCnt | 1.3.6.1.4.1.2011.5.104.1.2.1.1.4 | Counter32 | read-only | The port receive ethernet frames count. |
| C32 hwGonuTxPloamCellsCnt | 1.3.6.1.4.1.2011.5.104.1.2.1.1.5 | Counter32 | read-only | The port transmit PLOAM cells count. |
| C32 hwGonuRxPloamCellsCnt | 1.3.6.1.4.1.2011.5.104.1.2.1.1.6 | Counter32 | read-only | The port receive PLOAM cells count. |
| C32 hwGonuRxServiceFramesCnt | 1.3.6.1.4.1.2011.5.104.1.2.1.1.7 | Counter32 | read-only | The port receive service frames count. |
| INT hwGonuStatisticsClear | 1.3.6.1.4.1.2011.5.104.1.2.1.1.8 | INTEGER | read-write | Clear the statistics of this port. Options: 1. resetStat(1) - Clear the statistics 2. invalid(-1) - Invalid value |
| C32 hwGonuRxGemFramesCnt | 1.3.6.1.4.1.2011.5.104.1.2.1.1.9 | Counter32 | read-only | The port receive GEM frames count. |
| C32 hwGonuTxGemFramesCnt | 1.3.6.1.4.1.2011.5.104.1.2.1.1.10 | Counter32 | read-only | The port transmit GEM frames count. |
| C32 hwGonuRxCpuFramesCnt | 1.3.6.1.4.1.2011.5.104.1.2.1.1.11 | Counter32 | read-only | The CPU receive frames count. |
| C32 hwGonuRxDiscardEthFramesCnt | 1.3.6.1.4.1.2011.5.104.1.2.1.1.12 | Counter32 | read-only | The port discard receive ethernet frames count. |
| C32 hwGonuRxAndTxDiscardEthFramesCnt | 1.3.6.1.4.1.2011.5.104.1.2.1.1.13 | Counter32 | read-only | The up and down discard ethernet frames count. |
| C32 hwGonuRxFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.14 | Counter32 | read-only | The PON receive frames. |
| C64 hwGonuPonRxOctetsCnt | 1.3.6.1.4.1.2011.5.104.1.2.1.1.15 | Counter64 | read-only | The PON receive bytes. Unit: Bytes |
| C32 hwGonuRxUnicastFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.16 | Counter32 | read-only | The PON receive unicast frames. |
| C32 hwGonuRxMulticastFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.17 | Counter32 | read-only | The PON receive multicast frames. |
| C32 hwGonuRxBroadcastFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.18 | Counter32 | read-only | The PON receive broadcast frames. |
| C32 hwGonuRx64BytesFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.19 | Counter32 | read-only | The PON receive frames of 64 bytes. |
| C32 hwGonuRx65to127BytesFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.20 | Counter32 | read-only | The PON receive frames of 65~127 bytes. |
| C32 hwGonuRx128to255BytesFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.21 | Counter32 | read-only | The PON receive frames of 128~255 bytes. |
| C32 hwGonuRx256to511BytesFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.22 | Counter32 | read-only | The PON receive frames of 256~511 bytes. |
| C32 hwGonuRx512to1023BytesFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.23 | Counter32 | read-only | The PON receive frames of 512~1023 bytes. |
| C32 hwGonuRx1024to1518BytesFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.24 | Counter32 | read-only | The PON receive frames of 1024~1518 bytes. |
| C32 hwGonuRxOver1518BytesFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.25 | Counter32 | read-only | The PON receive frames of over 1518 bytes. |
| C32 hwGonuRxUndersizeFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.26 | Counter32 | read-only | The PON receive under size frames. |
| C32 hwGonuRxOversizeFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.27 | Counter32 | read-only | The PON receive over size frames. |
| C32 hwGonuRxCrcErrorFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.28 | Counter32 | read-only | The PON receive crc error frames. |
| C32 hwGonuRxDiscardedFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.29 | Counter32 | read-only | The PON receive discarded frames. |
| C32 hwGonuTxFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.30 | Counter32 | read-only | The PON send frames. |
| C64 hwGonuPonTxOctetsCnt | 1.3.6.1.4.1.2011.5.104.1.2.1.1.31 | Counter64 | read-only | The PON send bytes. Unit: Bytes |
| C32 hwGonuTxUnicastFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.32 | Counter32 | read-only | The PON send unicast frames. |
| C32 hwGonuTxMulticastFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.33 | Counter32 | read-only | The PON send multicast frames. |
| C32 hwGonuTxBroadcastFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.34 | Counter32 | read-only | The PON send broadcast frames. |
| C32 hwGonuTx64BytesFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.35 | Counter32 | read-only | The PON send frames of 64 bytes. |
| C32 hwGonuTx65to127BytesFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.36 | Counter32 | read-only | The PON send frames of 65~127 bytes. |
| C32 hwGonuTx128to255BytesFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.37 | Counter32 | read-only | The PON send frames of 128~255 bytes. |
| C32 hwGonuTx256to511BytesFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.38 | Counter32 | read-only | The PON send frames of 256~511 bytes. |
| C32 hwGonuTx512to1023BytesFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.39 | Counter32 | read-only | The PON send frames of 512~1023 bytes. |
| C32 hwGonuTx1024to1518BytesFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.40 | Counter32 | read-only | The PON send frames of 1024~1518 bytes. |
| C32 hwGonuTxOver1518BytesFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.41 | Counter32 | read-only | The PON send frames of over 1518 bytes. |
| C32 hwGonuPonRxErrFramesCnt | 1.3.6.1.4.1.2011.5.104.1.2.1.1.42 | Counter32 | read-only | The receive error ethernet frames count. |
| C32 hwGonuTxServiceFramesCnt | 1.3.6.1.4.1.2011.5.104.1.2.1.1.43 | Counter32 | read-only | The port transmit service frames count. |
| C32 hwGonuTxDiscardedFrames | 1.3.6.1.4.1.2011.5.104.1.2.1.1.44 | Counter32 | read-only | The PON transmit discarded frames. |
| hwGonuTcont | 1.3.6.1.4.1.2011.5.104.1.3 | |||
| hwGonuTcontTable | 1.3.6.1.4.1.2011.5.104.1.3.1 | not-accessible | The table hwGonuTcontTable contains T-Cont of the ONU that is allocated by OLT. The index of this table is a combination of ifIndex and hwGonuTcontIdIndex. | |
| hwGonuTcontEntry | 1.3.6.1.4.1.2011.5.104.1.3.1.1 | not-accessible | The table hwGonuTcontTable contains T-Cont of the ONU that is allocated by OLT. The index of this entry is a combination of ifIndex and hwGonuTcontIdIndex. | |
| U32 hwGonuTcontIdIndex | 1.3.6.1.4.1.2011.5.104.1.3.1.1.1 | Unsigned32 | read-only | The index of the T-Cont |
| U32 hwGonuAllocId | 1.3.6.1.4.1.2011.5.104.1.3.1.1.2 | Unsigned32 | read-only | The alloc id of the T-Cont |
| hwGonuAuth | 1.3.6.1.4.1.2011.5.104.1.4 | |||
| hwGonuAuthTable | 1.3.6.1.4.1.2011.5.104.1.4.1 | not-accessible | The table hwGonuAuthTable contains GPON ONU authentication information. The index of this table is ifIndex. | |
| hwGonuAuthEntry | 1.3.6.1.4.1.2011.5.104.1.4.1.1 | not-accessible | The table hwGonuAuthTable contains GPON ONU authentication information. The index of this entry is ifIndex. | |
| OCT hwGonuSerialNumber | 1.3.6.1.4.1.2011.5.104.1.4.1.1.1 | OCTET STRING | read-only | The serial number of the GPON ONU. |
| OCT hwGonuPassWord | 1.3.6.1.4.1.2011.5.104.1.4.1.1.2 | OCTET STRING | read-write | The password of the GPON ONU. GPON password size (0..10). XG-PON password size (0..36). |
| OCT hwGonuPsk | 1.3.6.1.4.1.2011.5.104.1.4.1.1.3 | OCTET STRING | read-write | The Psk hex value of the GPON ONU. |
| OCT hwGonuLoid | 1.3.6.1.4.1.2011.5.104.1.4.1.1.4 | OCTET STRING | read-write | The loid value of the GPON ONU. |
| OCT hwGonuCheckCode | 1.3.6.1.4.1.2011.5.104.1.4.1.1.5 | OCTET STRING | read-write | The checkcode value of the GPON ONU. |
| hwGponNNICfg | 1.3.6.1.4.1.2011.5.104.1.5 | |||
| hwGponNNICfgTable | 1.3.6.1.4.1.2011.5.104.1.5.1 | not-accessible | The table hwGponNNICfgTable config the GEM traffic descriptor that specifies the maximum rate. The index of this table is ifIndex. | |
| hwGponNNICfgEntry | 1.3.6.1.4.1.2011.5.104.1.5.1.1 | not-accessible | The table hwGponNNICfgTable config the GEM traffic descriptor that specifies the maximum rate. The index of this entry is ifIndex. | |
| I32 hwGponNNITrafficBroadcast | 1.3.6.1.4.1.2011.5.104.1.5.1.1.1 | Integer32 | read-write | Traffic broadcast of GPON Port, Traffic suppression ID definition: --------------------------------------------------------------------- NO. Min bandwidth(kbps) Max bandwidth(kbps) Package number(pps) --------------------------------------------------------------------- 1 6 145 12 2 12 291 24 3 24 582 48 4 48 1153 95 5 97 2319 191 6 195 4639 382 7 390 9265 763 8 781 18531 1526 9 1562 37063 3052 10 3125 74126 6104 11 6249 148241 12207 12 12499 296483 24414 13 0 0 0 --------------------------------------------------------------------- |
| I32 hwGponNNITrafficMulticast | 1.3.6.1.4.1.2011.5.104.1.5.1.1.2 | Integer32 | read-write | Traffic multicast of GPON Port, Traffic suppression ID definition: --------------------------------------------------------------------- NO. Min bandwidth(kbps) Max bandwidth(kbps) Package number(pps) --------------------------------------------------------------------- 1 6 145 12 2 12 291 24 3 24 582 48 4 48 1153 95 5 97 2319 191 6 195 4639 382 7 390 9265 763 8 781 18531 1526 9 1562 37063 3052 10 3125 74126 6104 11 6249 148241 12207 12 12499 296483 24414 13 0 0 0 --------------------------------------------------------------------- |
| I32 hwGponNNITrafficUnknowncast | 1.3.6.1.4.1.2011.5.104.1.5.1.1.3 | Integer32 | read-write | Traffic unicast of GPON Port, Traffic suppression ID definition: --------------------------------------------------------------------- NO. Min bandwidth(kbps) Max bandwidth(kbps) Package number(pps) --------------------------------------------------------------------- 1 6 145 12 2 12 291 24 3 24 582 48 4 48 1153 95 5 97 2319 191 6 195 4639 382 7 390 9265 763 8 781 18531 1526 9 1562 37063 3052 10 3125 74126 6104 11 6249 148241 12207 12 12499 296483 24414 13 0 0 0 --------------------------------------------------------------------- |
| INT hwXponNNIUplinkMode | 1.3.6.1.4.1.2011.5.104.1.5.2 | INTEGER | read-write | The object is used to config the uplink mode of PON ports. Options: 1.independent(1) - The uplink mode is independent 2.active-standby(2) - The uplink mode is active or standby The default value is active-standby(2). |
| hwGponNNIHistoryStats | 1.3.6.1.4.1.2011.5.104.1.6 | |||
| hwGponNNIHistoryStatsTable | 1.3.6.1.4.1.2011.5.104.1.6.1 | not-accessible | The table of GponNNI History Statistic. The index of this table is a combination of ifIndex, hwGponStatsIntervalType and hwGponStatsIntervalNum. | |
| hwGponNNIHistoryStatsEntry | 1.3.6.1.4.1.2011.5.104.1.6.1.1 | not-accessible | The table of GponNNI History Statistic. The index of this entry is a combination of ifIndex, hwGponStatsIntervalType and hwGponStatsIntervalNum. | |
| INT hwGponStatsIntervalType | 1.3.6.1.4.1.2011.5.104.1.6.1.1.1 | INTEGER | not-accessible | The type of GponNNI History Statistic, Options: 1. intervaltime15min(0) - The gponNNI history statistic in 15 minutes 2. intervaltime24h(1) - The gponNNI history statistic in 24 hours 3. everbefore(2) - All the gponNNI history statistic |
| I32 hwGponStatsIntervalNum | 1.3.6.1.4.1.2011.5.104.1.6.1.1.2 | Integer32 | not-accessible | The interval number of GponNNI History Statistic. |
| C64 hwGponStatsRxOmciMsg | 1.3.6.1.4.1.2011.5.104.1.6.1.1.3 | Counter64 | read-only | The number of received OMCI messages. |
| C64 hwGponStatsTxOmciMsg | 1.3.6.1.4.1.2011.5.104.1.6.1.1.4 | Counter64 | read-only | The number of transmited OMCI messages. |
| C64 hwGponStatsRxPloamMsg | 1.3.6.1.4.1.2011.5.104.1.6.1.1.5 | Counter64 | read-only | The number of received PLOAM messages. |
| C64 hwGponStatsTxPloamMsg | 1.3.6.1.4.1.2011.5.104.1.6.1.1.6 | Counter64 | read-only | The number of transmited PLOAM messages. |
| C64 hwGponStatsRxGemFrames | 1.3.6.1.4.1.2011.5.104.1.6.1.1.7 | Counter64 | read-only | The number of received GEM frames. |
| C64 hwGponStatsTxGemFrames | 1.3.6.1.4.1.2011.5.104.1.6.1.1.8 | Counter64 | read-only | The number of transmited GEM frames. |
| C64 hwGponStatsRxEthFrames | 1.3.6.1.4.1.2011.5.104.1.6.1.1.9 | Counter64 | read-only | The number of received Ethernet frames. |
| C64 hwGponStatsTxEthFrames | 1.3.6.1.4.1.2011.5.104.1.6.1.1.10 | Counter64 | read-only | The number of transmited Ethernet frames. |
| C64 hwGponStatsRxDiscardEthFrames | 1.3.6.1.4.1.2011.5.104.1.6.1.1.11 | Counter64 | read-only | The number of discarded Ethernet frames. |
| I32 hwGponTimeElapsed | 1.3.6.1.4.1.2011.5.104.1.6.1.1.12 | Integer32 | read-only | The elapsed time of the current interval. |
| T/F hwGponValidInterval | 1.3.6.1.4.1.2011.5.104.1.6.1.1.13 | TruthValue | read-only | Whether the interval number is valid. |
| hwGonuAlarmThreshold | 1.3.6.1.4.1.2011.5.104.1.7 | |||
| hwGonuAlarmThresholdTable | 1.3.6.1.4.1.2011.5.104.1.7.1 | not-accessible | The table GponNni alarm threshold. The index of this table is ifIndex. | |
| hwGonuAlarmThresholdEntry | 1.3.6.1.4.1.2011.5.104.1.7.1.1 | not-accessible | The table GponNni alarm threshold. The index of this entry is ifIndex. | |
| I32 hwGonuRxPowerUpperThreshold | 1.3.6.1.4.1.2011.5.104.1.7.1.1.1 | Integer32 | read-write | The MDU Rx-power upper limit threshold. Unit: 1/100 dBm |
| I32 hwGonuRxPowerLowerThreshold | 1.3.6.1.4.1.2011.5.104.1.7.1.1.2 | Integer32 | read-write | The MDU Rx-power lower limit threshold. Unit: 1/100 dBm |
| I32 hwGonuTxPowerUpperThreshold | 1.3.6.1.4.1.2011.5.104.1.7.1.1.3 | Integer32 | read-write | The MDU Tx-power upper limit threshold. Unit: 1/100 dBm |
| I32 hwGonuTxPowerLowerThreshold | 1.3.6.1.4.1.2011.5.104.1.7.1.1.4 | Integer32 | read-write | The MDU Tx-power lower limit threshold. Unit: 1/100 dBm |
| I32 hwGonuBiasUpperThreshold | 1.3.6.1.4.1.2011.5.104.1.7.1.1.5 | Integer32 | read-write | The MDU bias current upper limit threshold. Unit: mA |
| I32 hwGonuBiasLowerThreshold | 1.3.6.1.4.1.2011.5.104.1.7.1.1.6 | Integer32 | read-write | The MDU bias current lower limit threshold. Unit: mA |
| I32 hwGonuTemperatureUpperThreshold | 1.3.6.1.4.1.2011.5.104.1.7.1.1.7 | Integer32 | read-write | The MDU Temperature upper limit threshold. Unit: 1/100 degree centigrade |
| I32 hwGonuTemperatureLowerThreshold | 1.3.6.1.4.1.2011.5.104.1.7.1.1.8 | Integer32 | read-write | The MDU Temperature lower limit threshold. Unit: 1/100 degree centigrade |
| I32 hwGonuVoltageUpperThreshold | 1.3.6.1.4.1.2011.5.104.1.7.1.1.9 | Integer32 | read-write | The MDU Voltage upper limit threshold. Unit: 1/100 V |
| I32 hwGonuVoltageLowerThreshold | 1.3.6.1.4.1.2011.5.104.1.7.1.1.10 | Integer32 | read-write | The MDU Voltage lower limit threshold. Unit: 1/100 V |
| INT hwGonuClearThreshold | 1.3.6.1.4.1.2011.5.104.1.7.1.1.11 | INTEGER | read-write | Clear the MDU threshold. Options: 1. invalid(0) - The MDU threshold clear state is invalid. 2. clear(1) - Clear the MDU threshold. 3. cleared(32767) - The MDU threshold is cleared. |
| hwGonuTrapsVbOids | 1.3.6.1.4.1.2011.5.104.1.8 | |||
| INT hwGonuOperType | 1.3.6.1.4.1.2011.5.104.1.8.1 | INTEGER | accessible-for-notify | Operation type. Options: 1. add(1) - Add 2. modify(2) - Modify 3. delete(3) - Delete |
| hwGonuTraps | 1.3.6.1.4.1.2011.5.104.2 | |||
| hwGonuCommonTraps | 1.3.6.1.4.1.2011.5.104.2.1 | |||
| hwGonuCommonTrapsPrefix | 1.3.6.1.4.1.2011.5.104.2.1.0 | |||
| NTF hwGonuAuthChangeTrap | 1.3.6.1.4.1.2011.5.104.2.1.0.1 | This trap is sent when the authentication information changes. |
RFC description
Huawei GPON ONU MIB for managing GPON NNI interfaces and ONU-specific parameters on optical networks.
Start monitoring Huawei GPON Optical Network Unit (ONU) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.