All MIBs › HPNSATRAP-MIB
Category: Alarm and Event Management, Domain: Server Hardware, Vendor: HP/HPE
Description: Defines SNMP trap notifications for HP NetServer Agent hardware alerts and fault events on HP ProLiant servers.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is HPNSATRAP-MIB?
HPNSATRAP-MIB is part of the legacy HP NetServer Agent suite and defines the SNMP trap notifications for hardware alert and fault events on HP ProLiant/NetServer servers, with a clear focus on SCSI/RAID storage subsystems. Its sample objects reference SCSI adapter, logical drive, channel, and target IDs along with SCSI sense-key/ASC/ASCQ error codes, indicating the traps report detailed storage controller and drive fault diagnostics. Its monitoring purpose is hardware status and fault detection: capturing logical drive state transitions (rtOldDriveState to rtNewDriveState) and detailed SCSI error codes so operators can pinpoint exactly which adapter, channel, and drive experienced a failure and why. It depends on/complements sibling HP NetServer Agent MIBs such as HPNSAASR-MIB (array redundancy) and HPNSATAT-MIB (drive self-test), which expose the underlying polled data that these traps report on. It would have been deployed on legacy HP NetServer/ProLiant servers to alert administrators in real time to RAID controller and drive faults.
IPNetwork Monitor allows you to monitor SNMP objects defined in HPNSATRAP-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- HP NetServer/ProLiant servers with SCSI/RAID controllers
Monitoring Examples
An NMS receiving a trap from this MIB would read rtAdapterNumber, rtChannelNumber, and rtTargetID together to identify exactly which physical drive triggered the alert, then check rtOldDriveState versus rtNewDriveState to see the drive transitioned, for example, from online to failed. The rtSenseKey, rtASC, and rtASCQ fields provide the underlying SCSI error code detail (and rtDriveVendor identifies the manufacturer), letting a storage admin distinguish a transient bus error from a genuine drive failure without manually querying the RAID controller, and administrators supporting this legacy platform can download the HPNSATRAP-MIB file directly to load it into a MIB browser.
What Can Be Monitored
- logical drive state changes
- SCSI adapter/channel/target identification
- SCSI sense key and ASC/ASCQ error codes
- drive vendor identification
This MIB depends on
Related MIBs
Imported Objects
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| enterprises |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| hp | 1.3.6.1.4.1.11 | |||
| nm | 1.3.6.1.4.1.11.2 | |||
| hpnsa | 1.3.6.1.4.1.11.2.23 | |||
| NTF hpnsaStorageCapWarning | 1.3.6.1.4.1.11.2.23.0.4096 | Volume Storage Capacity has exceeded the warning threshold level. | ||
| NTF hpnsaStorageCapMinor | 1.3.6.1.4.1.11.2.23.0.4097 | Volume Storage Capacity has exceeded the minor threshold level. | ||
| NTF hpnsaStorageCapMajor | 1.3.6.1.4.1.11.2.23.0.4098 | Volume Storage Capacity has exceeded the major threshold level. | ||
| NTF hpnsaPostError | 1.3.6.1.4.1.11.2.23.0.4356 | Post Error has occurred. | ||
| NTF hpnsaDiskSysDefects | 1.3.6.1.4.1.11.2.23.0.8210 | The Defect List Threshold has been exceeded. | ||
| NTF hpnsaDaCacheError | 1.3.6.1.4.1.11.2.23.0.8609 | HPDA Controller: Cache Error | ||
| NTF hpnsaDaLogicalDriveTrap | 1.3.6.1.4.1.11.2.23.0.8625 | HPDA Logical Drive: Critical | ||
| NTF hpnsaDaLogicalDriveNotAvailable | 1.3.6.1.4.1.11.2.23.0.8626 | HPDA Logical Drive Not Available | ||
| NTF hpnsaDaHotSpareFailure | 1.3.6.1.4.1.11.2.23.0.8641 | HPDA Hot Spare:Failed | ||
| NTF hpnsaDaHotSpareSuccess | 1.3.6.1.4.1.11.2.23.0.8642 | HPDA Hot Spare Succeeded | ||
| NTF hpnsaDaHardDiskFailure | 1.3.6.1.4.1.11.2.23.0.8657 | HPDA Hard Disk Failed | ||
| NTF hpnsaDaParityThresholdTrap | 1.3.6.1.4.1.11.2.23.0.8673 | HPDA Threshold Exceeded: Parity | ||
| NTF hpnsaDaSoftErrorThresholdTrap | 1.3.6.1.4.1.11.2.23.0.8674 | HPDA Threshold Exceeded: Soft Errors | ||
| NTF hpnsaDaHardwareThresholdTrap | 1.3.6.1.4.1.11.2.23.0.8675 | HPDA Threshold Exceeded: Hardware Errors | ||
| NTF hpnsaDaMiscThresholdTrap | 1.3.6.1.4.1.11.2.23.0.8676 | HPDA Threshold Exceeded: Miscellaneous Errors | ||
| NTF hpnsaDaControllerTrap | 1.3.6.1.4.1.11.2.23.0.8677 | HPDA Controller: NVRAM Age | ||
| NTF hpnsaRPSAbnormalCondition | 1.3.6.1.4.1.11.2.23.0.9101 | The Redundant Power Supply module is not operating properly, but there is no power supply module hardware failure. | ||
| NTF hpnsaRPSACPowerSourceFailure | 1.3.6.1.4.1.11.2.23.0.9103 | Indicates a failure with the AC power source that is connected to one of the redundant power supply units. | ||
| NTF hpnsaRPSPsuFailureDetected | 1.3.6.1.4.1.11.2.23.0.9105 | Indicates that one of the redundant power supply modules is not in normal operating condition. | ||
| NTF hpnsaRPSDCShutdown | 1.3.6.1.4.1.11.2.23.0.9106 | Indicates that one of the redundant power supply modules is in over temperature protection mode. | ||
| NTF hpnsaRPSPsuRemoved | 1.3.6.1.4.1.11.2.23.0.9107 | Indicates that one of the redundant power supply modules has been physically removed from the HP NetServer Power Supply Subsystem. | ||
| NTF hpnsaRPSPsuInserted | 1.3.6.1.4.1.11.2.23.0.9108 | Indicates that one of the redundant power supply modules has been physically inserted into the HP NetServer Power Supply Subsystem. | ||
| NTF hpnsaRPSPowerRestored | 1.3.6.1.4.1.11.2.23.0.9109 | Indicates that one of the redundant power supply modules in the HP NetServer has recovered from an over temperature protection mode. | ||
| NTF hpnsaRPSWarningExceeded | 1.3.6.1.4.1.11.2.23.0.9110 | Indicates that one of the redundant power supply modules in the HP NetServer has exceeded the warning temperature level. | ||
| NTF hpnsaRPSEmergencyExceeded | 1.3.6.1.4.1.11.2.23.0.9111 | Indicates that one of the redundant power supply modules in the HP NetServer has exceeded the emergency temperature level. | ||
| NTF hpnsaTempMonitorError | 1.3.6.1.4.1.11.2.23.0.12288 | Server temperature monitor cannot read temperature data. | ||
| NTF hpnsaTempTrapWarning | 1.3.6.1.4.1.11.2.23.0.12289 | Server temperature has exceeded the warning temperature threshold. | ||
| NTF hpnsaTempTrapEmergency | 1.3.6.1.4.1.11.2.23.0.12290 | Server temperature has exceeded the emergency temperature threshold. | ||
| NTF hpnsaNicReceiveErrors | 1.3.6.1.4.1.11.2.23.0.16385 | The total number of packets with receive errors has exceeded the threshold. | ||
| NTF hpnsaNicTransmitErrors | 1.3.6.1.4.1.11.2.23.0.16386 | The total number of packets with transmit errors has exceeded the threshold. | ||
| NTF hpnsaNicAdapterReset | 1.3.6.1.4.1.11.2.23.0.16387 | The total number of LAN Adapter reset errors has exceeded the threshold. | ||
| NTF hpnsaNicAlignmentErrors | 1.3.6.1.4.1.11.2.23.0.16388 | The total number of alignment and CRC errors has exceeded the threshold. | ||
| NTF hpnsaNicGiantFrameErrors | 1.3.6.1.4.1.11.2.23.0.16389 | The total number of giant frame packets has exceeded the threshold. | ||
| NTF hpnsaNicHardwareMismatch | 1.3.6.1.4.1.11.2.23.0.16390 | The total number of packets with length less than the required minimum length has exceeded the threshold. | ||
| NTF hpnsaNicLateCollision | 1.3.6.1.4.1.11.2.23.0.16391 | The total number of late collision errors has exceeded the threshold (the network is too large). | ||
| NTF hpnsaNicExcessiveCollision | 1.3.6.1.4.1.11.2.23.0.16392 | The total number of colliding packets has exceeded the threshold (the network is too busy). | ||
| NTF hpnsaNicCarrierSenseError | 1.3.6.1.4.1.11.2.23.0.16393 | The total number of carrier sense errors has exceeded the threshold. | ||
| NTF hpnsaNicDeferralError | 1.3.6.1.4.1.11.2.23.0.16394 | The total number of adapter deferrals has exceeded the threshold (the network is forever busy). | ||
| NTF hpnsaNicNoECBError | 1.3.6.1.4.1.11.2.23.0.16395 | The total number of No ECB errors (LAN adapter is out of receive buffers) errors has exceeded the threshold. | ||
| NTF hpnsaNicReceiveOverflow | 1.3.6.1.4.1.11.2.23.0.16396 | The total number of Receive Overflow errors has exceeded the threshold. | ||
| NTF hpnsaNicUtilCount | 1.3.6.1.4.1.11.2.23.0.16397 | LAN adapter utilization count has exceeded the threshold. | ||
| NTF hpnsaNicAdapterMismatch | 1.3.6.1.4.1.11.2.23.0.16398 | The LAN adapter which the alarms were configured for, has been replaced by another type of LAN adapter. | ||
| NTF hpnsaNicTxFIFOUnderrun | 1.3.6.1.4.1.11.2.23.0.16399 | There possibly is a dataflow problem with your HP LAN adapter. | ||
| NTF hpnsaNicTxTimeOut | 1.3.6.1.4.1.11.2.23.0.16400 | The HP LAN adapter driver did not receive a transmit complete interrupt. | ||
| NTF hpnsaNicRxFIFOOverrun | 1.3.6.1.4.1.11.2.23.0.16401 | There possibly is a dataflow problem with your HP LAN adapter. | ||
| NTF hpnsaNicRxFalseInterrupts | 1.3.6.1.4.1.11.2.23.0.16402 | There is a dataflow problem with your HP LAN adapter - receive interrupts are being generated, but no receive packets are being present. | ||
| NTF hpnsaNicPagingError | 1.3.6.1.4.1.11.2.23.0.16403 | There possibly is a problem with your HP LAN adapter - it generates too many buffer pointer errors. | ||
| NTF hpnsaNicTimedOutDMA | 1.3.6.1.4.1.11.2.23.0.16404 | There possibly is a problem with your HP LAN adapter - DMA timed out while transmitting or receiving a packet. | ||
| NTF hpnsaNicTxNoResources | 1.3.6.1.4.1.11.2.23.0.16405 | The HP LAN adapter is transmitting faster than the media can handle. | ||
| NTF hpnsaNicTxExcessiveFrags | 1.3.6.1.4.1.11.2.23.0.16406 | The number of buffer fragments has exceeded the maximum number allowed by the network protocol in your HP LAN adapter. | ||
| NTF hpnsaNicRxLow | 1.3.6.1.4.1.11.2.23.0.16407 | The total number of errors due to requests of an ECB being denied has exceeded the threshold. | ||
| NTF hpnsaNicRxEmpty | 1.3.6.1.4.1.11.2.23.0.16408 | There possibly is a problem with your HP LAN adapter running in bus master mode. | ||
| NTF hpnsaParityError | 1.3.6.1.4.1.11.2.23.0.20528 | Parity error has been detected in parity memory | ||
| NTF hpnsaBusTimeoutError | 1.3.6.1.4.1.11.2.23.0.20544 | One of the bus masters caused a bus timeout | ||
| NTF hpnsaIOChannelCheck | 1.3.6.1.4.1.11.2.23.0.20560 | I/0 channel check activated by device in EISA slot caused an error | ||
| NTF hpnsaSoftwareNMI | 1.3.6.1.4.1.11.2.23.0.20576 | Software NMI has been generated | ||
| NTF hpnsaPostMemoryResize | 1.3.6.1.4.1.11.2.23.0.20592 | Memory size has been adjusted during the Power-On-Self-Test during the last boot | ||
| NTF hpnsaPciParityError | 1.3.6.1.4.1.11.2.23.0.20624 | Parity error has occurred on a transfer to/from a device on one of the PCI buses | ||
| NTF hpnsaPciSystemError | 1.3.6.1.4.1.11.2.23.0.20640 | System error has occurred in the PCI subsystem | ||
| NTF hpnsaCPUFailure | 1.3.6.1.4.1.11.2.23.0.20656 | One or more CPUs have failed. Detected by BIOS during POST | ||
| NTF hpnsaFailsafeTimeout | 1.3.6.1.4.1.11.2.23.0.20672 | Timeout of failsafe timer has occurred | ||
| NTF hpnsaErrorLoggingDisabled | 1.3.6.1.4.1.11.2.23.0.20704 | Error logging for a specific error has been disabled due to too many errors of that kind in a short time period | ||
| NTF hpnsaSystemWarning | 1.3.6.1.4.1.11.2.23.0.20736 | An event of warning severity has occurred in the system. For example, chassis door has been opened | ||
| NTF hpnsaSystemCritical | 1.3.6.1.4.1.11.2.23.0.20737 | An event of critical severity has occurred in the system. For example, both system fans have failed | ||
| NTF hpnsaVoltEmergency | 1.3.6.1.4.1.11.2.23.0.20738 | Fatal voltage threshold on one of the system voltage channels has been exceeded. Voltage channels are +12V, +5V, -12V, +3.3V to PCI, +3.3V to CPU | ||
| NTF hpnsaVoltWarning | 1.3.6.1.4.1.11.2.23.0.20739 | Warning voltage threshold on one of the system voltage channels has been exceeded. Voltage channels are +12V, +5V, -12V, +3.3V to PCI, +3.3V to CPU | ||
| NTF hpnsaASRServerRestart | 1.3.6.1.4.1.11.2.23.0.20752 | Server has been restarted after the system watchdog timer has timed out due to NOS being hung | ||
| NTF hpnsaSystemReconfig | 1.3.6.1.4.1.11.2.23.0.20800 | EISA Configuration Utility has altered system configuration | ||
| NTF hpnsaHotSwapTempMonitorError | 1.3.6.1.4.1.11.2.23.0.24449 | Hot Swap Cage: Temperature monitor error occurred | ||
| NTF hpnsaHotSwapTempWarning | 1.3.6.1.4.1.11.2.23.0.24451 | Hot Swap Cage: Warning temperature exceeded | ||
| NTF hpnsaHotSwapTempEmergency | 1.3.6.1.4.1.11.2.23.0.24452 | Hot Swap Cage: Emergency temperature exceeded! | ||
| NTF hpnsaHotSwapPowerFailure | 1.3.6.1.4.1.11.2.23.0.24453 | Power connection failure in one of the devices in the hot swap cage | ||
| NTF hpnsaHotSwapDeviceRemoved | 1.3.6.1.4.1.11.2.23.0.24454 | A device has been removed from the hot swap cage | ||
| NTF hpnsaHotSwapDeviceInserted | 1.3.6.1.4.1.11.2.23.0.24455 | A device has been inserted into the hot swap cage | ||
| hpnsaECC | 1.3.6.1.4.1.11.2.23.6 | |||
| NTF hpnsaEccErrorCorrected | 1.3.6.1.4.1.11.2.23.6.0.4353 | An ECC single-bit error has been corrected in one of the memory modules | ||
| NTF hpnsaEccSBEOverflow | 1.3.6.1.4.1.11.2.23.6.0.4354 | Error logging for ECC single-bit errors has been disabled due to too many SBE's detected in a short time period | ||
| NTF hpnsaEccMemoryResize | 1.3.6.1.4.1.11.2.23.6.0.4355 | ECC Memory size has been adjusted during the Power-On-Self-Test during the last boot due to a failed memory module | ||
| NTF hpnsaEccMultiBitError | 1.3.6.1.4.1.11.2.23.6.0.4357 | An ECC double-bit error has occurred in one of the memory modules | ||
| NTF hpnsaEccMultiBitErrorOverflow | 1.3.6.1.4.1.11.2.23.6.0.4358 | Error logging for ECC multiple-bit errors has been disabled due to too many MBE's detected in a short time period | ||
| hpnsaRemoteAssist | 1.3.6.1.4.1.11.2.23.8 | |||
| NTF hpnsaRAVoltServerPowerFailure | 1.3.6.1.4.1.11.2.23.8.0.109 | The server has lost the power completely. | ||
| NTF hpnsaRAVoltMinus12VUpper | 1.3.6.1.4.1.11.2.23.8.0.111 | Voltage measured in the server has gone outside of -12V Upper Threshold. | ||
| NTF hpnsaRAVoltPlus3VUpper | 1.3.6.1.4.1.11.2.23.8.0.113 | Voltage measured in the server has gone outside of +3.3V Upper Threshold. | ||
| NTF hpnsaRAVoltPlus5VUpper | 1.3.6.1.4.1.11.2.23.8.0.114 | Voltage measured in the server has gone outside of +5V Upper Threshold. | ||
| NTF hpnsaRAVoltPlus12VUpper | 1.3.6.1.4.1.11.2.23.8.0.115 | Voltage measured in the server has gone outside of +12V Upper Threshold. | ||
| NTF hpnsaRAVoltMinus12VLower | 1.3.6.1.4.1.11.2.23.8.0.121 | Voltage measured in the server has gone outside of -12V Lower Threshold. | ||
| NTF hpnsaRAVoltBatteryLower | 1.3.6.1.4.1.11.2.23.8.0.122 | The HP Remote Assistant Card's battery charging circuit is bad. | ||
| NTF hpnsaRAVoltPlus3VLower | 1.3.6.1.4.1.11.2.23.8.0.123 | Voltage measured in the server has gone outside of +3.3V Lower Threshold. | ||
| NTF hpnsaRAVoltPlus5VLower | 1.3.6.1.4.1.11.2.23.8.0.124 | Voltage measured in the server has gone outside of +5V Lower Threshold. | ||
| NTF hpnsaRAVoltPlus12VLower | 1.3.6.1.4.1.11.2.23.8.0.125 | Voltage measured in the server has gone outside of +12V Lower Threshold. | ||
| NTF hpnsaRATempWarning | 1.3.6.1.4.1.11.2.23.8.0.211 | The server temperature measured on the HP Remote Assistant Card has exceeded the configured warning threshold. | ||
| NTF hpnsaRATempShutdown | 1.3.6.1.4.1.11.2.23.8.0.221 | The server temperature measured on the HP Remote Assistant Card has exceeded the configured threshold and the server has been automatically shut down. | ||
| NTF hpnsaRATempCritical | 1.3.6.1.4.1.11.2.23.8.0.231 | The server temperature measured on the HP Remote Assistant Card has exceeded the configured Graceful Shutdown threshold value by 5 degrees C and the server has been automatically shut down. | ||
| NTF hpnsaRASuccessfulLogin | 1.3.6.1.4.1.11.2.23.8.0.401 | An administrator has logged in to the HP Remote Assistant Card. | ||
| NTF hpnsaRAIllegalLogin | 1.3.6.1.4.1.11.2.23.8.0.402 | An unauthorized user has made 3 or more unsuccessful attempts to log in to the HP Remote Assistant Card within a 5-minute period of time. | ||
| NTF hpnsaRALowBatteryCharge | 1.3.6.1.4.1.11.2.23.8.0.403 | The HP Remote Assistant Card's battery charging circuit is bad. | ||
| NTF hpnsaRABoardShutDown | 1.3.6.1.4.1.11.2.23.8.0.404 | The HP Remote Assistant Card has been shut down. | ||
| NTF hpnsaRAAdminstratorLogout | 1.3.6.1.4.1.11.2.23.8.0.405 | An administrator disconnected from the HP Remote Assistant board. | ||
| NTF hpnsaRAAdministratorAutologout | 1.3.6.1.4.1.11.2.23.8.0.406 | An administrator has been automatically disconnected from the HP Remote Assistant board. The administrator was inactive for more than five minutes. | ||
| NTF hpnsaRAAdministratorConnectionLost | 1.3.6.1.4.1.11.2.23.8.0.407 | An administrator has been prematurely disconnected from the Remote Assistant board. | ||
| NTF hpnsaRAAdministratorDialbackFailed | 1.3.6.1.4.1.11.2.23.8.0.408 | An administrator failed to connect to the HP Remote Assistant board on a dialback | ||
| NTF hpnsaRAASRHangNOS | 1.3.6.1.4.1.11.2.23.8.0.501 | ASR has stopped notifying the HP Remote Assistant Card that the system is running correctly (the server probably hung or crashed). | ||
| NTF hpnsaRAASRServerRestart | 1.3.6.1.4.1.11.2.23.8.0.502 | The HP Remote Assistant card has restarted the server due to the NOS being hung. | ||
| NTF hpnsaRAASRTimerEnabled | 1.3.6.1.4.1.11.2.23.8.0.503 | The Automatic Server Restart software has been enabled by the Remote Assistant ASR timer. | ||
| NTF hpnsaRAASRTimerDisabled | 1.3.6.1.4.1.11.2.23.8.0.504 | The HP Remote Assistant Automatic Server Restart timer has been disabled. | ||
| NTF hpnsaRARemoteInitiatedCtrlAltDel | 1.3.6.1.4.1.11.2.23.8.0.601 | An administrator has executed a remote on the server via the HP Remote Assistant Card. | ||
| NTF hpnsaRARemoteInitiatedReset | 1.3.6.1.4.1.11.2.23.8.0.602 | An administrator has executed a remote power cycle on the server via the HP Remote Assistant Card. | ||
| NTF hpnsaRARemoteInitiatedPowerDown | 1.3.6.1.4.1.11.2.23.8.0.603 | An administrator has executed a remote power down of the server via the HP Remote Assistant Card. | ||
| NTF hpnsaRAInitServerBIOS | 1.3.6.1.4.1.11.2.23.8.0.701 | The server's BIOS has successfully initialized the HP Remote Assistant Card during the boot process. | ||
| NTF hpnsaRABusUtilization | 1.3.6.1.4.1.11.2.23.8.0.800 | The 5-minute average EISA bus utilization has exceeded the configured threshold. | ||
| NTF hpnsaRATestNotification | 1.3.6.1.4.1.11.2.23.8.0.900 | An administrator has executed Test Page from the HP Remote Assistant Configuration Utility. | ||
| NTF hpnsaRATAPNoConnect | 1.3.6.1.4.1.11.2.23.8.0.901 | The HP Remote Assistant modem was unable to connect to the TAP paging service modem. | ||
| NTF hpnsaRATAPParam1Error | 1.3.6.1.4.1.11.2.23.8.0.902 | HP Remote Assistant was unable to connect with the TAP paging service. | ||
| NTF hpnsaRATAPParam2Error | 1.3.6.1.4.1.11.2.23.8.0.903 | HP Remote Assistant was unable to log on to the TAP paging service. | ||
| NTF hpnsaRATAPParam3Error | 1.3.6.1.4.1.11.2.23.8.0.904 | The HP Remote Assistant pager message was rejected by the TAP paging service. | ||
| hpnr | 1.3.6.1.4.1.16 | |||
| hpNetRAID | 1.3.6.1.4.1.16.1 | |||
| hpNetRaidMib | 1.3.6.1.4.1.16.1.1 | |||
| raidTraps | 1.3.6.1.4.1.16.1.1.200 | |||
| NTF rtConfigUpdated | 1.3.6.1.4.1.16.1.1.200.0.9001 | Adapter-%d: A New Configuration has been written. | ||
| NTF rtPhysicalDriveStateChange | 1.3.6.1.4.1.16.1.1.200.0.9002 | Adapter-%d, Channel-%d, Target-%d: Drive State Changed from %s to %s. | ||
| NTF rtLogicalDriveStateChange | 1.3.6.1.4.1.16.1.1.200.0.9003 | Adapter-%d, Logical Drive-%d: State Changed from %s to %s. | ||
| NTF rtInitializeStarted | 1.3.6.1.4.1.16.1.1.200.0.9004 | Adapter-%d, Logical Drive-%d: Initialization Started. | ||
| NTF rtInitializeCompleted | 1.3.6.1.4.1.16.1.1.200.0.9005 | Adapter-%d, Logical Drive-%d: Initialization Completed Successfully. | ||
| NTF rtInitializeAborted | 1.3.6.1.4.1.16.1.1.200.0.9006 | Adapter-%d, Logical Drive-%d: Initialization Aborted by User. | ||
| NTF rtInitializeFailed | 1.3.6.1.4.1.16.1.1.200.0.9007 | Adapter-%d, Logical Drive-%d: Initialization Failed. | ||
| NTF rtCheckConsistencyStarted | 1.3.6.1.4.1.16.1.1.200.0.9008 | Adapter-%d, Logical Drive-%d: Check Consistency Started. | ||
| NTF rtCheckConsistencyCompleted | 1.3.6.1.4.1.16.1.1.200.0.9009 | Adapter-%d, Logical Drive-%d: Check Consistency Completed. No Inconsistencies Found. | ||
| NTF rtCheckConsistencyAborted | 1.3.6.1.4.1.16.1.1.200.0.9010 | Adapter-%d, Logical Drive-%d: Check Consistency Aborted by User. | ||
| NTF rtConsistencyCorrected | 1.3.6.1.4.1.16.1.1.200.0.9011 | Adapter-%d, Logical Drive-%d: Check Consistency Operation Completed. Inconsistencies have been Cured. | ||
| NTF rtCheckConsistencyFailed | 1.3.6.1.4.1.16.1.1.200.0.9012 | Adapter-%d, Logical Drive-%d: Check Consistency Failed. | ||
| NTF rtReconstructionStarted | 1.3.6.1.4.1.16.1.1.200.0.9013 | Adapter-%d, Logical Drive-%d: Reconstruction Started. | ||
| NTF rtReconstructionCompleted | 1.3.6.1.4.1.16.1.1.200.0.9014 | Adapter-%d, Logical Drive-%d: Reconstruction Completed Successfully. | ||
| NTF rtReconstructionFailed | 1.3.6.1.4.1.16.1.1.200.0.9015 | Adapter-%d, Logical Drive-%d: Reconstruction Failed. | ||
| NTF rtPredictiveFailuresFalse | 1.3.6.1.4.1.16.1.1.200.0.9016 | Adapter-%d, Channel-%d, Target-%d: Reported Failure Prediction Threshold Exceeded [FALSE]. Drive Identification String = %s Sense Key = 0x%x, ASC = 0x%x, ASCQ = 0x%x. | ||
| NTF rtPredictiveFailuresExceeded | 1.3.6.1.4.1.16.1.1.200.0.9017 | Adapter-%d, Channel-%d, Target-%d: Reported Predictive Failure. Drive Identification String = %s Sense Key = 0x%x, ASC = 0x%x, ASCQ = 0x%x. | ||
| NTF rtCheckConditionStatus | 1.3.6.1.4.1.16.1.1.200.0.9018 | Adapter-%d, Channel-%d, Target-%d: Command Completed with Sense_Key-0x%x ASC-0x%x ASCQ-0x%x. | ||
| NTF rtNewDriveInserted | 1.3.6.1.4.1.16.1.1.200.0.9019 | Adapter-%d, Channel-%d, Target-%d: New Device Inserted. | ||
| NTF rtBatteryMissing | 1.3.6.1.4.1.16.1.1.200.0.9020 | Adapter-%d: Battery Module is missing. | ||
| NTF rtBatteryVolatageLow | 1.3.6.1.4.1.16.1.1.200.0.9021 | Adapter-%d: Battery Module Voltage is Low. | ||
| NTF rtBatteryTemperatureHigh | 1.3.6.1.4.1.16.1.1.200.0.9022 | Adapter-%d: Battery Module Temperature Exceeded Danger Threshold. | ||
| INT rtAdapterNumber | 1.3.6.1.4.1.16.1.1.200.1001 | INTEGER | read-only | Adapter Number for which Trap is generated. |
| INT rtLogicalDriveNumber | 1.3.6.1.4.1.16.1.1.200.1002 | INTEGER | read-only | Logical Drive Number for which Trap is generated. |
| INT rtChannelNumber | 1.3.6.1.4.1.16.1.1.200.1003 | INTEGER | read-only | Channel Number on the Adapter for which Trap is Generated. |
| INT rtTargetID | 1.3.6.1.4.1.16.1.1.200.1004 | INTEGER | read-only | Device ID of the Physical Drive for which Trap is Generated. |
| STR rtOldDriveState | 1.3.6.1.4.1.16.1.1.200.1005 | DisplayString | read-only | Old State of Logical/Physical Drive, when a State Change Trap is Generated. |
| STR rtNewDriveState | 1.3.6.1.4.1.16.1.1.200.1006 | DisplayString | read-only | New State of Logical/Physical Drive, when a State Change Trap is Generated. |
| INT rtSenseKey | 1.3.6.1.4.1.16.1.1.200.1007 | INTEGER | read-only | Check Condition Sense-Key reported by Physical Drive for which Trap is Generated. |
| INT rtASC | 1.3.6.1.4.1.16.1.1.200.1008 | INTEGER | read-only | Check Condition Additional Sense Code (ASC) reported by Physical Drive for which Trap is Generated. |
| INT rtASCQ | 1.3.6.1.4.1.16.1.1.200.1009 | INTEGER | read-only | Check Condition Additional Sense Code Qualifier (ASCQ) reported by Physical Drive for which Trap is Generated. |
| STR rtDriveVendor | 1.3.6.1.4.1.16.1.1.200.1010 | DisplayString | read-only | Vendor Identification String from the SCSI Inquiry Data for the Drive. |
| adaptec | 1.3.6.1.4.1.795 | |||
| storagemanagement | 1.3.6.1.4.1.795.2 | |||
| cyclone | 1.3.6.1.4.1.795.2.5 | |||
| NTF cycSNMPAgentIsUp | 1.3.6.1.4.1.795.2.5.0.101 | SNMP Agent is up. | ||
| NTF cycSNMPAgentIsDown | 1.3.6.1.4.1.795.2.5.0.102 | SNMP Agent is down. | ||
| NTF cycDuplicateHostAdapter | 1.3.6.1.4.1.795.2.5.0.107 | Cyclone: duplicate hostadapter ID | ||
| NTF cycHostAdapterDiscovered | 1.3.6.1.4.1.795.2.5.0.108 | The HostAdapter# %d with HostAdapter Id %s and Manager Id %s is discovered | ||
| NTF cycHostAdapterChanged | 1.3.6.1.4.1.795.2.5.0.109 | The HostAdapter# %d has new HostAdapter Id %s and Manager Id %s | ||
| NTF cycHostAdapterFailed | 1.3.6.1.4.1.795.2.5.0.110 | The HostAdapter# %d has Failed | ||
| NTF cycHostAdapterRecovered | 1.3.6.1.4.1.795.2.5.0.111 | Host Adapter# %d recovered | ||
| NTF cycDeviceFailed | 1.3.6.1.4.1.795.2.5.0.112 | The HostAdapter# %d , TargetID %d, Lun# %d has failed | ||
| NTF cycDeviceDiscovered | 1.3.6.1.4.1.795.2.5.0.113 | The HostAdapter# %d , TargetID %d, Lun# %d of vendor %s product %s has discovered | ||
| NTF cycDeviceRecovered | 1.3.6.1.4.1.795.2.5.0.114 | The HostAdapter# %d , TargetID %d, Lun# %d has recovered | ||
| NTF cycDeviceChanged | 1.3.6.1.4.1.795.2.5.0.115 | The HostAdapter# %d , TargetID %d, Lun# %d has new Vendor %s and Product %s information | ||
| NTF cycPredictiveFailure | 1.3.6.1.4.1.795.2.5.0.116 | The HostAdapter# %d , TargetID %d, Lun# %d has Predictive Failure Condition on vendor %s product %s with sense info MSB(sense code), next 8 bits(sense code Qual) next 8 bits (Add sense code Qual) LSB (0000) %d | ||
| NTF cycAspiDatabaseCleared | 1.3.6.1.4.1.795.2.5.0.117 | The Aspi database is cleared and therefore all the previous information are not available | ||
| NTF cycAspiCrash | 1.3.6.1.4.1.795.2.5.0.118 | The Aspi has crashed | ||
| NTF cycAspiNoMemory | 1.3.6.1.4.1.795.2.5.0.119 | No memory left for Aspi Operations | ||
| NTF cycAspiFileWriteOpenError | 1.3.6.1.4.1.795.2.5.0.120 | Unable to open Aspi file for writing, problem exists in server hard disk | ||
| NTF cycAspiFileWriteError | 1.3.6.1.4.1.795.2.5.0.121 | Unable to open Aspi file , problem exists in server hard disk | ||
| NTF cycAspiNoDeviceFile | 1.3.6.1.4.1.795.2.5.0.122 | Aspi device file doesnot exist | ||
| NTF cycAspiNoMemoryReading | 1.3.6.1.4.1.795.2.5.0.123 | Aspi: Memory allocation is failing | ||
| NTF cycAspiFileReadError | 1.3.6.1.4.1.795.2.5.0.124 | Aspi: unable to read the file server hard disk might have problems | ||
| NTF cycAspiBadFileMagic | 1.3.6.1.4.1.795.2.5.0.125 | Aspi: database is corrupted | ||
| cycTraps | 1.3.6.1.4.1.795.2.5.9000 | |||
| STR cycManagerID | 1.3.6.1.4.1.795.2.5.9000.9001 | DisplayString | read-only | ASCII String description of SCSI Manager |
| STR cycHostAdapterID | 1.3.6.1.4.1.795.2.5.9000.9002 | DisplayString | read-only | ASCII String description of Hostadapter |
| INT cycHostAdapterNumber | 1.3.6.1.4.1.795.2.5.9000.9003 | INTEGER | read-only | The unique Hostadapter Number |
| STR cycVendor | 1.3.6.1.4.1.795.2.5.9000.9004 | DisplayString | read-only | This indicates the Name of the Vendor |
| STR cycProduct | 1.3.6.1.4.1.795.2.5.9000.9005 | DisplayString | read-only | This indicates the product information |
| STR cycControllerModel | 1.3.6.1.4.1.795.2.5.9000.9006 | DisplayString | read-only | The model of the associated controller e.g ATHENA, VIKING etc |
| INT cycBusNumber | 1.3.6.1.4.1.795.2.5.9000.9007 | INTEGER | read-only | The PCI Bus number |
| INT cycChannelNumber | 1.3.6.1.4.1.795.2.5.9000.9008 | INTEGER | read-only | Channel Number |
| INT cycScsiTargetID | 1.3.6.1.4.1.795.2.5.9000.9009 | INTEGER | read-only | SCSI Target ID |
| INT cycLun | 1.3.6.1.4.1.795.2.5.9000.9010 | INTEGER | read-only | The LUN of the device ID |
| STR cycArrayName | 1.3.6.1.4.1.795.2.5.9000.9011 | DisplayString | read-only | Array name |
| INT cycMisCompares | 1.3.6.1.4.1.795.2.5.9000.9012 | INTEGER | read-only | The number of miscompares in verify |
| INT cycDriver | 1.3.6.1.4.1.795.2.5.9000.9013 | INTEGER | read-only | The Driver version |
| INT cycManager | 1.3.6.1.4.1.795.2.5.9000.9014 | INTEGER | read-only | The CI/O Manager version |
| STR cycOldArrayName | 1.3.6.1.4.1.795.2.5.9000.9015 | DisplayString | read-only | Old Array name |
| STR cycNewArrayName | 1.3.6.1.4.1.795.2.5.9000.9016 | DisplayString | read-only | Changed Array name |
| INT cycPriority | 1.3.6.1.4.1.795.2.5.9000.9017 | INTEGER | read-only | The Priority of the operation |
| INT cycSenseInfo | 1.3.6.1.4.1.795.2.5.9000.9018 | INTEGER | read-only | The sense info of the PFA |
| adaptecNm | 1.3.6.1.4.1.795.4 | |||
| adaptecNmScsiStatus | 1.3.6.1.4.1.795.4.1 | |||
| NTF hpnsaScsiStatusCorruptedDB | 1.3.6.1.4.1.795.4.1.0.8193 | Device Database has been corrupted. | ||
| NTF hpnsaScsiStatusUnloadedNLM | 1.3.6.1.4.1.795.4.1.0.8194 | SCSI Status agent was unloaded from a NetWare Server. | ||
| NTF hpnsaScsiStatusFailedHBA | 1.3.6.1.4.1.795.4.1.0.8196 | One of the SCSI HBAs can no longer be detected by the SCSI Status agent. | ||
| NTF hpnsaScsiStatusRecoveredHBA | 1.3.6.1.4.1.795.4.1.0.8197 | A Host Adapter which has failed, has become accessible again. | ||
| NTF hpnsaScsiStatusDiscoveredHBA | 1.3.6.1.4.1.795.4.1.0.8198 | A new SCSI Host Bus Adapter has been discovered or device database has been cleared. | ||
| NTF hpnsaScsiStatusDeviceFailed | 1.3.6.1.4.1.795.4.1.0.8199 | One of the SCSI devices installed on the server can no longer be detected by the SCSI Status agent. | ||
| NTF hpnsaScsiStatusDeviceRecovered | 1.3.6.1.4.1.795.4.1.0.8200 | A SCSI device which has failed, has become accessible again. | ||
| NTF hpnsaScsiStatusDeviceDiscovered | 1.3.6.1.4.1.795.4.1.0.8201 | A new SCSI device has been discovered. | ||
| NTF hpnsaScsiStatusChangedHBA | 1.3.6.1.4.1.795.4.1.0.8205 | The SCSI Status agent detected that the Host Bus Adapter has been changed. | ||
| NTF hpnsaScsiStatusDeviceChanged | 1.3.6.1.4.1.795.4.1.0.8206 | The SCSI Status agent detected that a SCSI device installed on the server has been changed. | ||
| NTF hpnsaScsiStatusTimeoutHBA | 1.3.6.1.4.1.795.4.1.0.8208 | The SCSI Status agent sent a request to an HBA and the request never completed. | ||
| NTF hpnsaScsiStatusDeviceTimeout | 1.3.6.1.4.1.795.4.1.0.8209 | The SCSI Status agent sent a request to a SCSI device and the request never completed. |
RFC description
Provides trap definitions for hardware alerts and events on HP NetServer systems.
Start monitoring HP NetServer/ProLiant server with SCSI/RAID controllers (hardware alert traps) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.