| OID symbolic | OID numeric | Type | Access | Description |
| hm2PoeMgmtMib | 1.3.6.1.4.1.248.11.12 | | | Hirschmann Power over Ethernet Management MIB. This MIB contains
the private extensions to the RFC 3621.
Copyright (C) 2011. All Rights Reserved. |
| hm2PoeMgmtMibNotifications | 1.3.6.1.4.1.248.11.12.0 | | | |
| NTF hm2PoeMgmtModulePowerUsageOnNotification | 1.3.6.1.4.1.248.11.12.0.1 | | | This Notification indicate PSE Threshold usage indication
is on, the usage power is above the threshold.
At least 500 msec must elapse between notifications being
emitted by the same object instance. |
| NTF hm2PoeMgmtModulePowerUsageOffNotification | 1.3.6.1.4.1.248.11.12.0.2 | | | This Notification indicate PSE Threshold usage indication
is on, the usage power is below the threshold.
At least 500 msec must elapse between notifications being
emitted by the same object instance. |
| NTF hm2PoeMgmtPortMaxConfiguredPowerLimitExceeded | 1.3.6.1.4.1.248.11.12.0.3 | | | This trap reports an exceeding of the configured power limit.
This notification indicates that a PD consumes more power
that the maximum configured on the port and the system reserved
the maximum power required for the negotiated class. |
| hm2PoeMgmtMibObjects | 1.3.6.1.4.1.248.11.12.1 | | | |
| hm2PoeMgmtGroup | 1.3.6.1.4.1.248.11.12.1.1 | | | |
| hm2PoeMgmtGlobalGroup | 1.3.6.1.4.1.248.11.12.1.1.1 | | | |
| HME hm2PoeMgmtAdminStatus | 1.3.6.1.4.1.248.11.12.1.1.1.1 | HmEnabledStatus | read-write | Enables/disables Power over Ethernet management on this device. |
| I32 hm2PoeMgmtReservedPower | 1.3.6.1.4.1.248.11.12.1.1.1.2 | Integer32 | read-only | Reserved system power for active Power over Ethernet ports in Watts. |
| hm2PoeMgmtPsuTable | 1.3.6.1.4.1.248.11.12.1.1.2 | | not-accessible | This table contains objects for each power supply type of
the device (internal or external power supply). |
| hm2PoeMgmtPsuEntry | 1.3.6.1.4.1.248.11.12.1.1.2.1 | | not-accessible | The entries of the hm2PoeMgmtPsuTable. |
| I32 hm2PoeMgmtPsuPower | 1.3.6.1.4.1.248.11.12.1.1.2.1.1 | Integer32 | read-only | The power budget per psu type expressed in Watts. Psu types could
be internal or external. |
| I32 hm2PoeMgmtPsuReservedPower | 1.3.6.1.4.1.248.11.12.1.1.2.1.2 | Integer32 | read-only | The reserved power (depending on actual power classes)
per psu type expressed in Watts. |
| I32 hm2PoeMgmtPsuDeliveredPower | 1.3.6.1.4.1.248.11.12.1.1.2.1.3 | Integer32 | read-only | The measured usage power per psu type expressed in Watts. |
| hm2PoeMgmtPortTable | 1.3.6.1.4.1.248.11.12.1.1.3 | | not-accessible | This table contains objects for each Power over Ethernet interface of
the device. |
| hm2PoeMgmtPortEntry | 1.3.6.1.4.1.248.11.12.1.1.3.1 | | not-accessible | The entry of the hm2PoeMgmtPortTable. |
| HME hm2PoeMgmtPortAdminEnable | 1.3.6.1.4.1.248.11.12.1.1.3.1.1 | HmEnabledStatus | read-write | enable (1) An interface which can provide the PSE functions.
disable(2) The interface will act - as it would - if it had no PSE
function. |
| I32 hm2PoeMgmtPortConsumptionPower | 1.3.6.1.4.1.248.11.12.1.1.3.1.2 | Integer32 | read-only | Measured usage power per interface expressed in Milliwatts. |
| INT hm2PoeMgmtPortDetectionStatus | 1.3.6.1.4.1.248.11.12.1.1.3.1.3 | INTEGER | read-only | Describes the operational status of the port PD detection.
A value of disabled(1)- indicates that the PSE State diagram
is in the state DISABLED.
A value of deliveringPower(3) - indicates that the PSE State
diagram is in the state POWER_ON.
A value of fault(4) - indicates that the PSE State diagram is
in the state TEST_ERROR.
A value of test(5) - indicates that the PSE State diagram is
in the state TEST_MODE.
A value of otherFault(6) - indicates that the PSE State
diagram is in the state IDLE due to the variable
error_conditions.
A value of searching(2)- indicates the PSE State diagram is
in a state other than those listed above. |
| INT hm2PoeMgmtPortPowerPriority | 1.3.6.1.4.1.248.11.12.1.1.3.1.4 | INTEGER | read-write | This object controls the priority of the port from the point
of view of a power management algorithm. The priority that
is set by this variable could be used by a control mechanism
that prevents over current situations by disconnecting first
ports with lower power priority. Ports that connect devices
critical to the operation of the network - like the E911
telephones ports - should be set to higher priority. |
| INT hm2PoeMgmtPortPowerClassification | 1.3.6.1.4.1.248.11.12.1.1.3.1.5 | INTEGER | read-only | Classification is a way to tag different terminals on the
Power over LAN network according to their power consumption.
Devices such as IP telephones, WLAN access points and others,
will be classified according to their power requirements.
The meaning of the classification labels is defined in the
IEEE specification.
This variable is valid only while a PD is being powered,
that is, while the attribute hm2PoeMgmtPortDetectionStatus
is reporting the enumeration deliveringPower. |
| STR hm2PoeMgmtPortName | 1.3.6.1.4.1.248.11.12.1.1.3.1.6 | SnmpAdminString | read-write | A manager will set the value of this variable to indicate
the type of powered device that is connected to the port.
The default value supplied by the agent if no value has
ever been set should be a zero-length octet string. |
| BIT hm2PoeMgmtPortAllowedClassBits | 1.3.6.1.4.1.248.11.12.1.1.3.1.7 | Bits | read-write | Bit mask which defines allowed classes per interface. |
| HME hm2PoeMgmtPortAutoShutdown | 1.3.6.1.4.1.248.11.12.1.1.3.1.8 | HmEnabledStatus | read-write | Enables/disables automatic shutdown functionality per interface. |
| HMT hm2PoeMgmtPortAutoShutdownTimeStart | 1.3.6.1.4.1.248.11.12.1.1.3.1.9 | HmTimeHHMM24 | read-write | Start time for the automatic shutdown functionality per interface. |
| HMT hm2PoeMgmtPortAutoShutdownTimeEnd | 1.3.6.1.4.1.248.11.12.1.1.3.1.10 | HmTimeHHMM24 | read-write | End time for the automatic shutdown functionality per interface. |
| INT hm2PoeMgmtPortClassValid | 1.3.6.1.4.1.248.11.12.1.1.3.1.11 | INTEGER | read-only | Evaluates if class represented through pethPsePortPowerClassifications
is valid or not. Class is valid if PD is delivered with power or in case
of power exceeding through a connected device. |
| HME hm2PoeMgmtPortFastStartup | 1.3.6.1.4.1.248.11.12.1.1.3.1.12 | HmEnabledStatus | read-write | Enables/disables Power over Ethernet fast startup mode on given port.
The default value is 'disable'. |
| I32 hm2PoeMgmtPortMaxConsumptionPower | 1.3.6.1.4.1.248.11.12.1.1.3.1.13 | Integer32 | read-only | The maximum observed power consumption (hm2PoeMgmtPortMaxConsumptionPower)
value expressed in milliwatts used by the PD.
The value is reset to 0 if the PoE admin state is set to disable
or if a disconnect of the PD is detected. |
| I32 hm2PoeMgmtPortPowerLimit | 1.3.6.1.4.1.248.11.12.1.1.3.1.14 | Integer32 | read-write | The power limit per port expressed in milliwatts. If set to
zero the power consumption limitation is disabled. |
| hm2PoeMgmtModuleTable | 1.3.6.1.4.1.248.11.12.1.1.4 | | not-accessible | This table contains objects for each plugged PoE module of
the device. If the device is non-modular and supports PoE it
contains only one entry. |
| hm2PoeMgmtModuleEntry | 1.3.6.1.4.1.248.11.12.1.1.4.1 | | not-accessible | The entries of the hm2PoeMgmtModuleTable. |
| I32 hm2PoeMgmtModuleUnitIndex | 1.3.6.1.4.1.248.11.12.1.1.4.1.1 | Integer32 | not-accessible | Unit number - for stacking devices. |
| I32 hm2PoeMgmtModuleSlotIndex | 1.3.6.1.4.1.248.11.12.1.1.4.1.2 | Integer32 | not-accessible | Slot number of the plugged PoE module. |
| I32 hm2PoeMgmtModulePower | 1.3.6.1.4.1.248.11.12.1.1.4.1.3 | Integer32 | read-write | Configurable power budget per module expressed in Watts. The default
value is hm2PoeMgmtModuleMaximumPower and depends on the hardware. |
| I32 hm2PoeMgmtModuleMaximumPower | 1.3.6.1.4.1.248.11.12.1.1.4.1.4 | Integer32 | read-only | Maximum available power budget per module expressed in Watts. This
value depends on the device or module. |
| I32 hm2PoeMgmtModuleReservedPower | 1.3.6.1.4.1.248.11.12.1.1.4.1.5 | Integer32 | read-only | The reserved power (depending on actual power classes)
per module expressed in Watts. |
| I32 hm2PoeMgmtModuleDeliveredPower | 1.3.6.1.4.1.248.11.12.1.1.4.1.6 | Integer32 | read-only | The measured usage power per module expressed in Watts. |
| INT hm2PoeMgmtModulePowerSource | 1.3.6.1.4.1.248.11.12.1.1.4.1.7 | INTEGER | read-only | This object displays the type of the PoE power source.
internal (0) means that the PoE power is used from the internal PSU and
external (1) means that a external PoE PSU must be installed and connected to this module. |
| I32 hm2PoeMgmtModuleUsageThreshold | 1.3.6.1.4.1.248.11.12.1.1.4.1.8 | Integer32 | read-write | The usage power threshold per module expressed in percent.
If this threshold is exceeded a alarm is initiated. |
| HME hm2PoeMgmtModuleNotificationControlEnable | 1.3.6.1.4.1.248.11.12.1.1.4.1.9 | HmEnabledStatus | read-write | This object controls, on a per-module basis, whether
or not notifications from the agent are enabled. |