HM2-POE-MIB :: hm2PoeMgmtReservedPower

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HM2-POE-MIB › hm2PoeMgmtReservedPower

hm2PoeMgmtReservedPower

Module: HM2-POE-MIB

OID (symbolic): HM2-POE-MIB::hm2PoeMgmtReservedPower

OID (numeric): 1.3.6.1.4.1.248.11.12.1.1.1.2

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Reserved system power for active Power over Ethernet ports in Watts.

What is hm2PoeMgmtReservedPower?

Reports, in watts, how much system power is currently reserved for all active PoE ports combined.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.11.12.1.1.1.2
snmpwalk -v2c -c public <target> HM2-POE-MIB::hm2PoeMgmtReservedPower

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.248.11.12.1.1.1.2.1
snmpget -v2c -c public <target> HM2-POE-MIB::hm2PoeMgmtReservedPower.1

Start monitoring Hirschmann HiOS industrial PoE Ethernet switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-POE-MIB::hm2PoeMgmtReservedPower OID value, configure state conditions and alerts, and monitor any Hirschmann HiOS industrial PoE Ethernet switch from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.248hirschmannHIRSCHMANN-GENERIC-ERROR-MIB
1.3.6.1.4.1.248.11hm2ConfigurationMibsHM2-TC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.248.11.12hm2PoeMgmtMibHM2-POE-MIB
1.3.6.1.4.1.248.11.12.1hm2PoeMgmtMibObjectsHM2-POE-MIB
1.3.6.1.4.1.248.11.12.1.1hm2PoeMgmtGroupHM2-POE-MIB
1.3.6.1.4.1.248.11.12.1.1.1hm2PoeMgmtGlobalGroupHM2-POE-MIB
1.3.6.1.4.1.248.11.12.1.1.1.2hm2PoeMgmtReservedPowerHM2-POE-MIB