Fore-E1-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › Fore-E1-MIB

Organization: FORE

Last Updated: 1999-11-05

Category: ATM, Domain: WAN/TDM, Vendor: Fore Systems (ATM)

Description: Fore Systems E1 interface MIB providing physical layer statistics and configuration for European E1 (2 Mbit/s) trunk modules in ForeRunner switches.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is Fore-E1-MIB?

Fore-E1-MIB is a Fore Systems proprietary MIB providing management for E1 (2.048 Mbit/s) physical-layer trunk port modules installed in ForeRunner ATM switches, the European counterpart to the DS3 module. It exposes per-port configuration objects for board/module/port identification, line type, line coding, transmit/receive line codes, loopback configuration, clock source, and a reported line status, along with a statistics group for line performance counters. Its monitoring focus is physical-layer configuration and hardware status, confirming an E1 trunk's line type/coding matches the carrier's provisioning, checking e1LineStatus to see if the port is reporting a signal/alarm condition, and detecting an inadvertently enabled loopback that would remove the trunk from service. It generally mirrors the structure of the IETF standard E1/DS1 MIB conventions though implemented as a Fore-specific module. It is deployed on ForeRunner ATM switches using E1 trunk cards, primarily in European and international carrier/enterprise ATM networks, and administrators typically begin with a Fore-E1-MIB download to load the module into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in Fore-E1-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Fore Systems ForeRunner ATM switches (E1 trunk port modules)

Monitoring Examples

An admin would poll e1ConfTable/e1ConfEntry, indexed by e1ConfBoard/e1ConfModule/e1ConfPort, to verify e1LineType and e1LineCoding match the carrier circuit's provisioning, and check e1LineStatus for an alarm condition such as loss of signal. Finding e1LoopbackConfig active on a port expected to be in service would explain an unexpected traffic outage on that E1 trunk. The e1StatsGroup performance counters would then be reviewed for error patterns suggesting a degrading physical link.

What Can Be Monitored

  • E1 line type/coding configuration
  • line status/alarm condition
  • loopback configuration state
  • line error/performance statistics
Imported Objects

From Fore-Common-MIB

asxOBJECT-IDENTITY

From SNMPv2-SMI

Counter32
Integer32
MODULE-IDENTITY
OBJECT-TYPE

How to Use in IPNetwork Monitor

Example using e1FramingLCVs OID:

Select a Fore Systems (later Marconi) ForeRunner ATM switch (E1 trunk port module) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type e1FramingLCVs into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of Line Code Violations (LCV) that were detected by the E1 Receive Framer block. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.
OIDs

RFC description

Vendor-private MIB for Fore Systems E1 WAN interface and circuit management.

Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch (E1 trunk port module) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download Fore-E1-MIB