| OID symbolic | OID numeric | Type | Access | Description |
| foreE3 | 1.3.6.1.4.1.326.2.2.1.1.5 | | | write something interesting here |
| e3ConfGroup | 1.3.6.1.4.1.326.2.2.1.1.5.1 | | | |
| e3ConfTable | 1.3.6.1.4.1.326.2.2.1.1.5.1.1 | | not-accessible | A table of E3 switch port configuration information. |
| e3ConfEntry | 1.3.6.1.4.1.326.2.2.1.1.5.1.1.1 | | not-accessible | A table entry containing E3 configuration information for each
port. Not all RFC1407 configuration table variables are
included, and some are modified. |
| I32 e3ConfBoard | 1.3.6.1.4.1.326.2.2.1.1.5.1.1.1.1 | Integer32 | read-only | The index of this port's switch board. |
| I32 e3ConfModule | 1.3.6.1.4.1.326.2.2.1.1.5.1.1.1.2 | Integer32 | read-only | The network module of this port. |
| I32 e3ConfPort | 1.3.6.1.4.1.326.2.2.1.1.5.1.1.1.3 | Integer32 | read-only | The number of this port. |
| INT e3LineType | 1.3.6.1.4.1.326.2.2.1.1.5.1.1.1.4 | INTEGER | read-write | This variable indicates the type of cell delineation being
used. The e3Plcp(3) value indicates cell delineation according
to CCITT G.751 using PLCP (Physical Layer Converhence Protocol)
framing, while e3Framed(2) indicates HCS (Header Check
Sequence) based framing. This variable is defined in the
rfc1407 configuration table as dsx3LineType.
According to RFC1407, the different values are:
e3Framed(2) specification: CCITT G.751
e3Plcp(3) specification: ETSI T/NA(91)18. |
| INT e3LineCoding | 1.3.6.1.4.1.326.2.2.1.1.5.1.1.1.5 | INTEGER | read-only | This variable describes the variety of Zero Code suppression
used on this interface, which in turn affects a number of its
characteristics. e3HDB3 (1) refers to the use of specified
pattern of normal bits and bipolar violations which are used to
replaced sequences of zero bits of specified length. This
variable is defined in the rfc1407 configuration table as
dsx3LineCoding. |
| INT e3SendCode | 1.3.6.1.4.1.326.2.2.1.1.5.1.1.1.6 | INTEGER | read-only | This variable indicates what type of code is being sent across
the E3/E3 interface by the device.
The values mean:
e3SendNoCode sending looped or normal data
e3SendLineCode sending request for a line loopback
e3SendPayloadCode sending a request for a payload loopback (i.e. all
DS1/E1 in a E3/E3 frame)
e3SendResetCode sending a loopback deactivation request
e3SendDS1LoopCode requesting to loopback a particular DS1/E1 within a
E3/E3 frame
e3SendTestPattern sending a test pattern. |
| INT e3ReceiveCode | 1.3.6.1.4.1.326.2.2.1.1.5.1.1.1.7 | INTEGER | read-only | This variable indicates the type of code that was received
across the E3/E3 interface.
The values mean:
e3ReceiveNoCode receiving looped or normal data
e3ReceiveLineCode receiving request for a line loopback
e3ReceivePayloadCode receiving a request for a payload loopback (i.e. all
DS1/E1 in a E3/E3 frame)
e3ReceiveResetCode receiving a loopback deactivation request
e3ReceiveDS1LoopCode receiving a request to loopback a particular DS1/E1
within a E3/E3 frame
e3ReceiveTestPattern receiving a test pattern. |
| INT e3LoopbackConfig | 1.3.6.1.4.1.326.2.2.1.1.5.1.1.1.8 | INTEGER | read-write | This variable represents the loopback configuration of the E3
interface. This variable is defined in the rfc1407
configuration table as dsx3LoopbackConfig, with slightly
different values.
e3NoLoop (1) means that the interface is not in a loopback
state.
e3CellLoop (2) means that cells that are processed by the
receiving component are not written into the receive FIFO, but
into the transmit FIFO for retransmission.
e3PayloadLoop (3) means that the receive signal is looped back
for retransmission after it has passed through the port's
reframing function.
e3DiagLoop (4) means that the transmit data stream is looped
back to the receiver.
e3LineLoop (5) means that the received data stream is reflected
back to the sender.
e3OtherLoop (6) means that the interface is in a loopback that
is not defined here. |
| INT e3TxClockSource | 1.3.6.1.4.1.326.2.2.1.1.5.1.1.1.9 | INTEGER | read-write | The source of the transmit clock. |
| INT e3RxScrambling | 1.3.6.1.4.1.326.2.2.1.1.5.1.1.1.10 | INTEGER | read-write | This variable indicates whether the information is being
descrambled on receiving. It should be set the same as the
transmitting side. |
| INT e3TxScrambling | 1.3.6.1.4.1.326.2.2.1.1.5.1.1.1.11 | INTEGER | read-write | This variable indicates whether the information (48 octet
payload) is being scrambled before transmitting. It should be
set the same as the receiving side. |
| INT e3LineStatus | 1.3.6.1.4.1.326.2.2.1.1.5.1.1.1.12 | INTEGER | read-only | This variable indicates the Line Status of the interface. A
similar object is defined in the rfc1407 configuration table as
dsx3LineStatus (the e3RxFERF bit is not defined in rfc1407)
. The variable contains loopback state information and failure
state information. It is a bit map represented as a sum. The
e3NoAlarm should be set if and only if no other flag is set.
The various bit positions are:
1 e3NoAlarm
2 e3RxAIS Receiving AIS failure state
4 e3TxAIS Transmitting AIS (Not used)
8 e3PLCPLOF Receiving PLCP LOF failure state
16 e3LOS Receiving LOS failure state
32 e3LoopbackState Looping the received signal
64 e3HcsLCD Loss of Cell Delineation (Not used)
128 e3RxFERF Receiving Far End Receive Failure
256 e3OtherFailure any line status not defined here.
512 e3RxPLCPYellow Receiving PLCP Yellow
1024 e3TxPLCPYellow Transmitting PLCP Yellow
2048 e3RxLOF Receving LOF alarm.
4096 e3TxFERF Transmitting FERF
32768 e3RxLCD Receiving LCD failure indication |
| INT e3IdleUnassignedCells | 1.3.6.1.4.1.326.2.2.1.1.5.1.1.1.13 | INTEGER | read-write | This variable indicates the types of cells that should be sent
in case there is no real data to send. According to the ATM
Forum, Unassigned cells should be sent (octet 1-3 are 0's,
octet 4 is 0000xxx0, where x is 'don't care'). According to the
CCITT specifications, Idle cells should be sent (everything is
'0' except for the CLP bit which is '1'). By default,
unassigned cells are transmitted is case there is no data to
send. |
| e3StatsGroup | 1.3.6.1.4.1.326.2.2.1.1.5.2 | | | |
| e3FramingTable | 1.3.6.1.4.1.326.2.2.1.1.5.2.1 | | not-accessible | A table of E3 framing statistics information. |
| e3FramingEntry | 1.3.6.1.4.1.326.2.2.1.1.5.2.1.1 | | not-accessible | A table entry containing E3 framing statistics information. |
| I32 e3FramingBoard | 1.3.6.1.4.1.326.2.2.1.1.5.2.1.1.1 | Integer32 | read-only | The index of this port's switch board. |
| I32 e3FramingModule | 1.3.6.1.4.1.326.2.2.1.1.5.2.1.1.2 | Integer32 | read-only | The network module of this port. |
| I32 e3FramingPort | 1.3.6.1.4.1.326.2.2.1.1.5.2.1.1.3 | Integer32 | read-only | The number of this port. |
| C32 e3FramingLOSsEx | 1.3.6.1.4.1.326.2.2.1.1.5.2.1.1.4 | Counter32 | read-only | The number of seconds in which Loss Of Signal (LOS) errors
were detected by the E3 Receive Framer block. |
| C32 e3FramingLCVs | 1.3.6.1.4.1.326.2.2.1.1.5.2.1.1.5 | Counter32 | read-only | The number of Line Code Violations (LCV) that were detected by
the E3 Receive Framer block. |
| C32 e3FramingFERRs | 1.3.6.1.4.1.326.2.2.1.1.5.2.1.1.6 | Counter32 | read-only | Number of E3 framing error (FERR) events. |
| C32 e3FramingOOFs | 1.3.6.1.4.1.326.2.2.1.1.5.2.1.1.7 | Counter32 | read-only | Number of seconds when E3 Out Of Frame (OOF) error events. |
| C32 e3FramingFERFs | 1.3.6.1.4.1.326.2.2.1.1.5.2.1.1.8 | Counter32 | read-only | In a G.832 (e3LineType == e3Framed) configured port, this
variable relects the number of seconds when Far End Receive
Failures were experienced. In G.751 (e3LineType == e3Plcp) it
is the number of Remote Alarm Indications. |
| C32 e3FramingAISs | 1.3.6.1.4.1.326.2.2.1.1.5.2.1.1.9 | Counter32 | read-only | The number of seconds in which Alarm Indication Signals (AIS)
were detected by the E3 Receive Framer block. AIS indicates
that an upstream failure has been detected by the far end. |
| C32 e3FramingBIP8s | 1.3.6.1.4.1.326.2.2.1.1.5.2.1.1.10 | Counter32 | read-only | The number of E3 G.832 BIP-8 errors. This counter is only
valid in G.832. |
| C32 e3FramingFEBEs | 1.3.6.1.4.1.326.2.2.1.1.5.2.1.1.11 | Counter32 | read-only | Number of E3 far end block error (FEBE) events. |
| e3PlcpTable | 1.3.6.1.4.1.326.2.2.1.1.5.2.2 | | not-accessible | A table of E3 Physical Layer Convergence Protocol (PLCP)
statistics information. These statistics are only valid when
the G.751 (PLCP) based framing is being used by the E3. They
are not meaningful when G.832 HCS-based framing is being used.
Check e3LineType for the current framing option. |
| e3PlcpEntry | 1.3.6.1.4.1.326.2.2.1.1.5.2.2.1 | | not-accessible | A table entry containing E3 PLCP statistics information. |
| I32 e3PlcpBoard | 1.3.6.1.4.1.326.2.2.1.1.5.2.2.1.1 | Integer32 | read-only | The index of this port's switch board. |
| I32 e3PlcpModule | 1.3.6.1.4.1.326.2.2.1.1.5.2.2.1.2 | Integer32 | read-only | The network module of this port. |
| I32 e3PlcpPort | 1.3.6.1.4.1.326.2.2.1.1.5.2.2.1.3 | Integer32 | read-only | The number of this port. |
| C32 e3PlcpFERRs | 1.3.6.1.4.1.326.2.2.1.1.5.2.2.1.4 | Counter32 | read-only | Number of Physical Layer Convergence Protocol (PLCP) octet
error events. |
| C32 e3PlcpLOFs | 1.3.6.1.4.1.326.2.2.1.1.5.2.2.1.5 | Counter32 | read-only | The number of seconds in which Loss Of Frame (LOF) errors were
detected by the PLCP (Physical Layer Convergence Protocol)
receiver. LOF is declared when an Out-Of-Frame state persists
for more than 1ms. LOF is removed when in-frame state persists
for more than 12ms. |
| C32 e3PlcpBIP8s | 1.3.6.1.4.1.326.2.2.1.1.5.2.2.1.6 | Counter32 | read-only | Number of BIP-8 (Bit Interleaved Parity - 8) error events. The
BIP-8 is calculated over the Path Overhead field and the
associated ATM cell of the previous frame. A BIP-N is a method
of error monitoring. An N bit code is generated by the
transmitting equipment in such a manner that the first bit of
the code provides even parity over the first bit of all N-bit
sequences in the previous VT SPE, the second bit provides even
parity over the second bits of all N-bit sequences within the
specified portion, etc. |
| C32 e3PlcpFEBEs | 1.3.6.1.4.1.326.2.2.1.1.5.2.2.1.7 | Counter32 | read-only | Number of ATM Far End Block Error (FEBE) events. |
| C32 e3PlcpYellows | 1.3.6.1.4.1.326.2.2.1.1.5.2.2.1.8 | Counter32 | read-only | The number of seconds in which Yellow alarm errors were
detected by the PLCP (Physical Layer Convergence Protocol)
receiver. Yellow alarm is asserted when 10 consecutive yellow
signal bits are set to logical 1. Yellow signals are used to
alert upstream terminals of a downstream failure in order to
initiate trunk conditioning on the failure circuit. |
| e3AtmTable | 1.3.6.1.4.1.326.2.2.1.1.5.2.3 | | not-accessible | A table of E3 ATM statistics information. |
| e3AtmEntry | 1.3.6.1.4.1.326.2.2.1.1.5.2.3.1 | | not-accessible | A table entry containing E3 ATM statistics information. |
| I32 e3AtmBoard | 1.3.6.1.4.1.326.2.2.1.1.5.2.3.1.1 | Integer32 | read-only | The index of this port's switch board. |
| I32 e3AtmModule | 1.3.6.1.4.1.326.2.2.1.1.5.2.3.1.2 | Integer32 | read-only | The network module of this port. |
| I32 e3AtmPort | 1.3.6.1.4.1.326.2.2.1.1.5.2.3.1.3 | Integer32 | read-only | The number of this port. |
| C32 e3AtmHCSs | 1.3.6.1.4.1.326.2.2.1.1.5.2.3.1.4 | Counter32 | read-only | Number of header check sequence (HCS) error events. The HCS is
a CRC-8 calculation over the first 4 octets of the ATM cell
header. |
| C32 e3AtmRxCells | 1.3.6.1.4.1.326.2.2.1.1.5.2.3.1.5 | Counter32 | read-only | Number of ATM cells that were received. |
| C32 e3AtmTxCells | 1.3.6.1.4.1.326.2.2.1.1.5.2.3.1.6 | Counter32 | read-only | Number of non-null ATM cells that were transmitted. |
| C32 e3AtmLCDs | 1.3.6.1.4.1.326.2.2.1.1.5.2.3.1.7 | Counter32 | read-only | The number of seconds in which Loss of Cell Delineation (LCD)
has occurred. An LCD defect is detected when an out of cell
delination state has persisted for 4ms. An LCD defect is
cleared when the sync state has been maintained for 4ms. |