Fore-E1-MIB :: e1LineLength

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › Fore-E1-MIB › e1LineLength

e1LineLength

Module: Fore-E1-MIB

OID (symbolic): Fore-E1-MIB::e1LineLength

OID (numeric): 1.3.6.1.4.1.326.2.2.1.1.8.1.1.1.12

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This variable represents the length of the physical cable connected to the e1 port. The user has to set this object to match the physical cable in order to get the netmod to receive the signal on the cable.

The different values are: e1LineLt110 (1) means the line is shorter than 110 ft, e1Line110-220 (2) means the line is between 110 and 220 ft, e1Line220-330 (3) means the line is between 220 and 330 ft, e1Line330-440 (4) means the line is between 330 and 440 ft, e1Line440-550 (5) means the line is between 440 and 550 ft, e1Line550-660 (6) means the line is between 550 and 660 ft, e1LineG703-75 (7) G703 standard (75 ohm coaxial line), e1LineG703-120 (8) G703 standard (120 ohm symmetrical line).

What is e1LineLength?

Tells the port the physical cable length or line-build-out standard in use (e.g. under 110 ft up to 550-660 ft, or the G.703 75/120-ohm standards), which must match the actual cable for the port to receive signal correctly.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.8.1.1.1.12
snmpwalk -v2c -c public <target> Fore-E1-MIB::e1LineLength

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.8.1.1.1.12.1
snmpget -v2c -c public <target> Fore-E1-MIB::e1LineLength.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.326.2.2.1.1.8.1.1.1.12.1 i <value>

Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch (E1 trunk port module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-E1-MIB::e1LineLength OID value, configure state conditions and alerts, and monitor any Fore Systems (later Marconi) ForeRunner ATM switch (E1 trunk port module) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.326foreCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2systemsCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2.2atmSwitchFore-Common-MIB
1.3.6.1.4.1.326.2.2.1hardwareFore-Common-MIB
1.3.6.1.4.1.326.2.2.1.1asxFore-Common-MIB
Numeric OIDNameModule
1.3.6.1.4.1.326.2.2.1.1.8foreE1Fore-E1-MIB
1.3.6.1.4.1.326.2.2.1.1.8.1e1ConfGroupFore-E1-MIB
1.3.6.1.4.1.326.2.2.1.1.8.1.1e1ConfTableFore-E1-MIB
1.3.6.1.4.1.326.2.2.1.1.8.1.1.1e1ConfEntryFore-E1-MIB
1.3.6.1.4.1.326.2.2.1.1.8.1.1.1.12e1LineLengthFore-E1-MIB