F3-CONNECTGUARD-MIB :: f3ConnectGuardFlowAssociatedMep

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › F3-CONNECTGUARD-MIB › f3ConnectGuardFlowAssociatedMep

f3ConnectGuardFlowAssociatedMep

Module: F3-CONNECTGUARD-MIB

OID (symbolic): F3-CONNECTGUARD-MIB::f3ConnectGuardFlowAssociatedMep

OID (numeric): 1.3.6.1.4.1.2544.1.12.36.1.1.1.28

Node type: OBJECT-TYPE

Type: VariablePointer

Access: read-write

Description: This object speicify the mep object to use as trigger for key exchange failure

What is f3ConnectGuardFlowAssociatedMep?

A pointer (OID reference) to a Maintenance End Point (MEP, from CFM/802.1ag-style monitoring) used as a trigger for detecting key-exchange failure on this flow. Lets the device tie MACsec key-exchange health to an independent connectivity-fault-management check.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.36.1.1.1.28
snmpwalk -v2c -c public <target> F3-CONNECTGUARD-MIB::f3ConnectGuardFlowAssociatedMep

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.36.1.1.1.28.1
snmpget -v2c -c public <target> F3-CONNECTGUARD-MIB::f3ConnectGuardFlowAssociatedMep.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.36.1.1.1.28.1 s <value>

Start monitoring ADVA Optical Networking FSP150CM/CC (F3 platform) carrier Ethernet device (Connect Guard link encryption) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the F3-CONNECTGUARD-MIB::f3ConnectGuardFlowAssociatedMep OID value, configure state conditions and alerts, and monitor any ADVA Optical Networking FSP150CM/CC (F3 platform) carrier Ethernet device (Connect Guard link encryption) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.36f3ConnectGuardMIBF3-CONNECTGUARD-MIB
1.3.6.1.4.1.2544.1.12.36.1f3ConnectGuardConfigObjectsF3-CONNECTGUARD-MIB
1.3.6.1.4.1.2544.1.12.36.1.1f3ConnectGuardFlowTableF3-CONNECTGUARD-MIB
1.3.6.1.4.1.2544.1.12.36.1.1.1f3ConnectGuardFlowEntryF3-CONNECTGUARD-MIB
1.3.6.1.4.1.2544.1.12.36.1.1.1.28f3ConnectGuardFlowAssociatedMepF3-CONNECTGUARD-MIB