DGPRPM-MIB :: rpmOutletC

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsDGPRPM-MIBrpmOutletC

rpmOutletC

Module: DGPRPM-MIB

OID (symbolic): DGPRPM-MIB::rpmOutletC

OID (numeric): 1.3.6.1.4.1.17420.1.1.3.2.1.9

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

What is rpmOutletC?

A writable text label for outlet C on this RPM unit, letting an admin assign a descriptive name (e.g. the attached device) rather than tracking outlets only by letter.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.17420.1.1.3.2.1.9
snmpwalk -v2c -c public <target> DGPRPM-MIB::rpmOutletC

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.17420.1.1.3.2.1.9.1
snmpget -v2c -c public <target> DGPRPM-MIB::rpmOutletC.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.17420.1.1.3.2.1.9.1 s <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> rpmOutletC.1

Start monitoring Networked Remote Power Manager (RPM) appliance with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DGPRPM-MIB::rpmOutletC OID value, configure state conditions and alerts, and monitor any Networked Remote Power Manager (RPM) appliance from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.17420dgpDGPPDU-MIB
1.3.6.1.4.1.17420.1productsDGPPDU-MIB
Numeric OIDNameModule
1.3.6.1.4.1.17420.1.1hardwareDGPRPM-MIB
1.3.6.1.4.1.17420.1.1.3rpmDGPRPM-MIB
1.3.6.1.4.1.17420.1.1.3.2rpmTableDGPRPM-MIB
1.3.6.1.4.1.17420.1.1.3.2.1rpmEntryDGPRPM-MIB
1.3.6.1.4.1.17420.1.1.3.2.1.9rpmOutletCDGPRPM-MIB