CM-SA-MIB :: esaProbeHistoryP2RErredPkts

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-SA-MIBesaProbeHistoryP2RErredPkts

esaProbeHistoryP2RErredPkts

Module: CM-SA-MIB

OID (symbolic): CM-SA-MIB::esaProbeHistoryP2RErredPkts

OID (numeric): 1.3.6.1.4.1.2544.1.12.8.1.8.1.9

Node type: OBJECT-TYPE

Type: PerfCounter64

Access: read-only

Description: The total number of Packets in the current interval, for which there was a problem in transmission. This error is counted when there is a failure in packet transmission due to resource limitations (buffers). This can happen if the Probe Configuration was changed to send in a large number of packets in a time interval.

NOTE: This is not applicable for Y.1731 probes.

What is esaProbeHistoryP2RErredPkts?

esaProbeHistoryP2RErredPkts is a 64-bit performance counter counting test packets from the probe to the reflector that failed to transmit because of local buffer/resource limits, for a completed interval that has already closed and been archived into the rolling history log; it does not apply to Y.1731 probes. A rising erred-packet count usually points to the probe itself running out of transmit buffers, which is a sign the configured packet rate is too aggressive for the platform rather than a fault in the network being tested. For example, finding this counter non-zero only in the archived bins right after a rate change was made explains, after the fact, why loss numbers briefly looked worse than the circuit really was.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.8.1.8.1.9
snmpwalk -v2c -c public <target> CM-SA-MIB::esaProbeHistoryP2RErredPkts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.8.1.8.1.9.1
snmpget -v2c -c public <target> CM-SA-MIB::esaProbeHistoryP2RErredPkts.1

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-SA-MIB::esaProbeHistoryP2RErredPkts OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.8cmServiceAssuranceMIBCM-SA-MIB
1.3.6.1.4.1.2544.1.12.8.1cmServAssuranceObjectsCM-SA-MIB
1.3.6.1.4.1.2544.1.12.8.1.8esaProbeHistoryTableCM-SA-MIB
1.3.6.1.4.1.2544.1.12.8.1.8.1esaProbeHistoryEntryCM-SA-MIB
1.3.6.1.4.1.2544.1.12.8.1.8.1.9esaProbeHistoryP2RErredPktsCM-SA-MIB