CM-SA-MIB :: esaProbeHistoryMaxAbsR2PJitter

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-SA-MIBesaProbeHistoryMaxAbsR2PJitter

esaProbeHistoryMaxAbsR2PJitter

Module: CM-SA-MIB

OID (symbolic): CM-SA-MIB::esaProbeHistoryMaxAbsR2PJitter

OID (numeric): 1.3.6.1.4.1.2544.1.12.8.1.8.1.65

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: This attribute is only applicable to Layer 3 ICMP Timestamp and Layer 2 Y.1731 probes. This is the maximum absolute R2P Jitter value. .

What is esaProbeHistoryMaxAbsR2PJitter?

esaProbeHistoryMaxAbsR2PJitter is an unsigned 32-bit value that reports the highest recorded absolute-value one-way jitter (magnitude of the delay swing regardless of direction), in microseconds, from the reflector back to the probe, applicable to Layer 3 ICMP-timestamp and Layer 2 Y.1731 probes, for a completed interval that has already closed and been archived into the rolling history log. Because it discards the sign of the swing, this absolute-jitter figure from the reflector back to the probe gives a technician a single severity number to alarm on without watching the positive and negative jitter counters separately. For example, scanning this worst-case absolute jitter from the reflector back to the probe across a week of archived bins lets the technician find the specific hour a transient spike occurred, long after the live dashboard has moved on to newer data.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.8.1.8.1.65
snmpwalk -v2c -c public <target> CM-SA-MIB::esaProbeHistoryMaxAbsR2PJitter

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.8.1.8.1.65.1
snmpget -v2c -c public <target> CM-SA-MIB::esaProbeHistoryMaxAbsR2PJitter.1

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-SA-MIB::esaProbeHistoryMaxAbsR2PJitter OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.8cmServiceAssuranceMIBCM-SA-MIB
1.3.6.1.4.1.2544.1.12.8.1cmServAssuranceObjectsCM-SA-MIB
1.3.6.1.4.1.2544.1.12.8.1.8esaProbeHistoryTableCM-SA-MIB
1.3.6.1.4.1.2544.1.12.8.1.8.1esaProbeHistoryEntryCM-SA-MIB
1.3.6.1.4.1.2544.1.12.8.1.8.1.65esaProbeHistoryMaxAbsR2PJitterCM-SA-MIB