All MIBs › CM-SA-MIB › ecpaControlStream2
ecpaControlStream2
Module: CM-SA-MIB
OID (symbolic): CM-SA-MIB::ecpaControlStream2
OID (numeric): 1.3.6.1.4.1.2544.1.12.8.1.1.1.9
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: This object specifies which stream should be included in the ECPA execution. Value of 0 indicates that no streams is selected by ecpaControlStream2. Non 0 value indicates the selected ECPA stream.
What is ecpaControlStream2?
This read-write Integer32, ranging 0 to 48, selects which pre-configured stream to include as the second stream in this ECPA test run; a value of 0 means no stream is selected here. It lets the operator add a second, independent test stream running in parallel with Stream1 for a mixed-traffic scenario. For example, setting ecpaControlStream2 to 12 runs a second stream, perhaps a bulk-data profile, simultaneously with Stream1 to see how the two traffic types interact on the link.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.8.1.1.1.9 snmpwalk -v2c -c public <target> CM-SA-MIB::ecpaControlStream2
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.8.1.1.1.9.1 snmpget -v2c -c public <target> CM-SA-MIB::ecpaControlStream2.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.8.1.1.1.9.1 i <value>
Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-SA-MIB::ecpaControlStream2 OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.12 | fsp150cm | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.12.8 | cmServiceAssuranceMIB | CM-SA-MIB |
| 1.3.6.1.4.1.2544.1.12.8.1 | cmServAssuranceObjects | CM-SA-MIB |
| 1.3.6.1.4.1.2544.1.12.8.1.1 | ecpaControlTable | CM-SA-MIB |
| 1.3.6.1.4.1.2544.1.12.8.1.1.1 | ecpaControlEntry | CM-SA-MIB |
| 1.3.6.1.4.1.2544.1.12.8.1.1.1.9 | ecpaControlStream2 | CM-SA-MIB |