All MIBs › CM-SA-MIB › ecpaConfigStreamInnerVlanId
ecpaConfigStreamInnerVlanId
Module: CM-SA-MIB
OID (symbolic): CM-SA-MIB::ecpaConfigStreamInnerVlanId
OID (numeric): 1.3.6.1.4.1.2544.1.12.8.1.2.1.14
Node type: OBJECT-TYPE
Type: VlanId
Access: read-write
Description: Inner VLAN Id associated with the ECPA stream. Valid only if ecpaConfigStreamInnerVlanEnabled is enabled.
What is ecpaConfigStreamInnerVlanId?
This read-write VlanId sets the inner VLAN Id for the stream template, valid only when ecpaConfigStreamInnerVlanEnabled is enabled. It sets the customer-facing VLAN ID used inside the outer provider tag for a Q-in-Q test stream. For example, setting InnerVlanId to 200 while OuterVlanId is 100 tests a Q-in-Q service exactly matching a customer's VLAN 200 nested in provider VLAN 100.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.8.1.2.1.14 snmpwalk -v2c -c public <target> CM-SA-MIB::ecpaConfigStreamInnerVlanId
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.8.1.2.1.14.1 snmpget -v2c -c public <target> CM-SA-MIB::ecpaConfigStreamInnerVlanId.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.8.1.2.1.14.1 s <value>
Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-SA-MIB::ecpaConfigStreamInnerVlanId OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.12 | fsp150cm | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.12.8 | cmServiceAssuranceMIB | CM-SA-MIB |
| 1.3.6.1.4.1.2544.1.12.8.1 | cmServAssuranceObjects | CM-SA-MIB |
| 1.3.6.1.4.1.2544.1.12.8.1.2 | ecpaConfigStreamTable | CM-SA-MIB |
| 1.3.6.1.4.1.2544.1.12.8.1.2.1 | ecpaConfigStreamEntry | CM-SA-MIB |
| 1.3.6.1.4.1.2544.1.12.8.1.2.1.14 | ecpaConfigStreamInnerVlanId | CM-SA-MIB |