CM-SA-MIB :: bertConfigStreamErrInjectRateMultiplier

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-SA-MIBbertConfigStreamErrInjectRateMultiplier

bertConfigStreamErrInjectRateMultiplier

Module: CM-SA-MIB

OID (symbolic): CM-SA-MIB::bertConfigStreamErrInjectRateMultiplier

OID (numeric): 1.3.6.1.4.1.2544.1.12.8.1.18.1.6

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: BER value with 0.1 Step, in this release is fixed 10, only applicable when Error Injection is enabled.

What is bertConfigStreamErrInjectRateMultiplier?

This read-write Integer32 is the BER value multiplier with a 0.1 step, fixed at 10 in this release per its description, applicable only when error injection is enabled. An administrator would combine this with bertConfigStreamErrInjectRate to express the injected error rate precisely, though in the current release the multiplier itself isn't variable since it's fixed at 10. For example, an operator computing the actual injected BER for a report would multiply the base rate object by this fixed value of 10 to get the effective rate.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.8.1.18.1.6
snmpwalk -v2c -c public <target> CM-SA-MIB::bertConfigStreamErrInjectRateMultiplier

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.8.1.18.1.6.1
snmpget -v2c -c public <target> CM-SA-MIB::bertConfigStreamErrInjectRateMultiplier.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.8.1.18.1.6.1 i <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-SA-MIB::bertConfigStreamErrInjectRateMultiplier OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.8cmServiceAssuranceMIBCM-SA-MIB
1.3.6.1.4.1.2544.1.12.8.1cmServAssuranceObjectsCM-SA-MIB
1.3.6.1.4.1.2544.1.12.8.1.18bertConfigStreamTableCM-SA-MIB
1.3.6.1.4.1.2544.1.12.8.1.18.1bertConfigStreamEntryCM-SA-MIB
1.3.6.1.4.1.2544.1.12.8.1.18.1.6bertConfigStreamErrInjectRateMultiplierCM-SA-MIB