CM-FACILITY-MIB :: f3TimeOfDayPortOutputFormat

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBf3TimeOfDayPortOutputFormat

f3TimeOfDayPortOutputFormat

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::f3TimeOfDayPortOutputFormat

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.55.1.10

Node type: OBJECT-TYPE

Type: TODOutputFormat

Access: read-write

Description: This object allows to set the Output Format for the Time Of Day port. The Output Format is used to determine the type of output format of the TOD port.

What is f3TimeOfDayPortOutputFormat?

This object selects the output format the Time Of Day port uses to encode its timestamp data. Admins set this to match the format the receiving device expects to parse, since a mismatch would make the timestamp unreadable downstream. For example, connecting a TOD port to a third-party timing receiver that expects a particular ToD string format requires setting f3TimeOfDayPortOutputFormat to match it.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.55.1.10
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::f3TimeOfDayPortOutputFormat

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.55.1.10.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::f3TimeOfDayPortOutputFormat.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.55.1.10.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::f3TimeOfDayPortOutputFormat OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.55f3TimeOfDayPortTableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.55.1f3TimeOfDayPortEntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.55.1.10f3TimeOfDayPortOutputFormatCM-FACILITY-MIB