Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::f3PulsePerSecondPortDirection

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.53.1.10

Node type: OBJECT-TYPE

Type: SignalDirectionType

Access: read-write

Description: This object allows specification of the signal type (i.e. input or output).

What is f3PulsePerSecondPortDirection?

This object specifies whether the PPS port is configured as a signal input or an output. Admins set the direction according to whether this port is meant to receive an external timing pulse or generate one for downstream equipment. For example, on a chassis distributing GPS-derived timing to external gear, the admin sets f3PulsePerSecondPortDirection to output so the port drives a PPS signal outward.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.53.1.10
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::f3PulsePerSecondPortDirection

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.53.1.10.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::f3PulsePerSecondPortDirection.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.53.1.10.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::f3PulsePerSecondPortDirection OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.53f3PulsePerSecondPortTableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.53.1f3PulsePerSecondPortEntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.53.1.10f3PulsePerSecondPortDirectionCM-FACILITY-MIB