CM-FACILITY-MIB :: cmTrafficAclDstIpV6Addr

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBcmTrafficAclDstIpV6Addr

cmTrafficAclDstIpV6Addr

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::cmTrafficAclDstIpV6Addr

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.38.1.17

Node type: OBJECT-TYPE

Type: Ipv6Address

Access: read-write

Description: The destination IPV6 address of Acl entry.

What is cmTrafficAclDstIpV6Addr?

This read-write Ipv6Address object specifies the destination IPv6 address that a traffic ACL rule matches against. Administrators configure it to filter IPv6 traffic by destination the same way cmTrafficAclDstIpV4Addr does for IPv4. For example, an operator blocking traffic toward a specific IPv6-only management address would set this object to that address.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.38.1.17
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmTrafficAclDstIpV6Addr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.38.1.17.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::cmTrafficAclDstIpV6Addr.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.38.1.17.1 s <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cmTrafficAclDstIpV6Addr.1

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmTrafficAclDstIpV6Addr OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.38cmTrafficAclRulesTableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.38.1cmTrafficAclRulesEntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.38.1.17cmTrafficAclDstIpV6AddrCM-FACILITY-MIB