CM-FACILITY-MIB :: cmPrioMapOuterTagPriority

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBcmPrioMapOuterTagPriority

cmPrioMapOuterTagPriority

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::cmPrioMapOuterTagPriority

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.10.1.6

Node type: OBJECT-TYPE

Type: VlanPriority

Access: read-write

Description: This allows specification of the VLAN priority that will replace the outgoing (A2N direction) outer-tag's priority. Note that, each flow participates or not in outer-tag priority mapping, using the object 'cmFlowOuterTagPrioEnabled'.

What is cmPrioMapOuterTagPriority?

This read-write VlanPriority object specifies the VLAN priority that will replace the outgoing (A2N direction) outer-tag's priority for a mapped priority value; whether a given flow actually participates in this remarking is controlled separately by cmFlowOuterTagPrioEnabled. Admins use it to remark the customer-facing outer tag's priority as traffic heads toward the network, ensuring the outer tag carries a priority the carrier's core network understands and trusts, rather than whatever a customer device originally set. For example, an admin wanting all traffic mapped to a given priority-map row to egress toward the network with outer-tag priority 6 would set cmPrioMapOuterTagPriority to 6, provided the relevant flow has outer-tag priority remarking enabled.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.10.1.6
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmPrioMapOuterTagPriority

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.10.1.6.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::cmPrioMapOuterTagPriority.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.10.1.6.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmPrioMapOuterTagPriority OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.10cmPrioMapTableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.10.1cmPrioMapEntryCM-FACILITY-MIB