CM-FACILITY-MIB :: cmOAMFlowPointSESFramesLossThresholdRatio

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBcmOAMFlowPointSESFramesLossThresholdRatio

cmOAMFlowPointSESFramesLossThresholdRatio

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::cmOAMFlowPointSESFramesLossThresholdRatio

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.30.1.10

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: This object is used to specify the frame-loss ratio per flow that starts counting Severely Errored Seconds (SES) on the oam flowpoint. This functionality is applicable if the oam flowpoint is monitored using the Y.1731 ESA functionality.

What is cmOAMFlowPointSESFramesLossThresholdRatio?

This read-write integer object specifies the frame-loss ratio, as a percentage, at which this OAMFlowPoint begins counting Severely Errored Seconds (SES), applicable only when the OAM flow point is monitored using Y.1731 Ethernet Service Assurance (ESA) functionality. An administrator tunes this threshold to control how sensitive SES reporting is for OAM-based SLA measurement on the monitored circuit. For example, setting this threshold tighter on a premium circuit's OAM flow point makes even small amounts of frame loss trigger SES counting for stricter SLA compliance tracking.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.30.1.10
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmOAMFlowPointSESFramesLossThresholdRatio

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.30.1.10.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::cmOAMFlowPointSESFramesLossThresholdRatio.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.30.1.10.1 i <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmOAMFlowPointSESFramesLossThresholdRatio OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.30cmOAMFlowPointTableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.30.1cmOAMFlowPointEntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.30.1.10cmOAMFlowPointSESFramesLossThresholdRatioCM-FACILITY-MIB