CM-FACILITY-MIB :: cmFlowRefConnectGuardFlowList

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBcmFlowRefConnectGuardFlowList

cmFlowRefConnectGuardFlowList

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::cmFlowRefConnectGuardFlowList

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.4.1.69

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: This object specifies the secure flow list, it should be f3ConnectGuardFlowIndex value list split with comma.

What is cmFlowRefConnectGuardFlowList?

This read-write DisplayString lists comma-separated f3ConnectGuardFlowIndex values naming the secure flow list the Ethernet Flow references. It associates this flow with a set of MACsec-secured ConnectGuard flows whose security status it depends on. For example, an administrator lists several ConnectGuard flow indexes here to associate this flow with a set of MACsec-secured flows it depends on.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.4.1.69
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmFlowRefConnectGuardFlowList

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.4.1.69.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::cmFlowRefConnectGuardFlowList.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.4.1.69.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmFlowRefConnectGuardFlowList OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.4cmFlowTableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.4.1cmFlowEntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.4.1.69cmFlowRefConnectGuardFlowListCM-FACILITY-MIB