CM-FACILITY-MIB :: cmFlowPointCpdProfileMac00DispType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBcmFlowPointCpdProfileMac00DispType

cmFlowPointCpdProfileMac00DispType

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::cmFlowPointCpdProfileMac00DispType

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.34.1.31

Node type: OBJECT-TYPE

Type: CmControlProtocolDispType

Access: read-write

Description: MAC Address 01:80:C2:00:00:00 Disposition type.

What is cmFlowPointCpdProfileMac00DispType?

This object determines how the device handles traffic destined to the specific MAC address 01:80:C2:00:00:00, which is a standard control protocol address used in network bridging. The disposition type controls the action taken on frames sent to this reserved multicast address, such as forwarding or filtering. A network manager would configure this to control how control plane traffic is processed on an interface.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.34.1.31
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmFlowPointCpdProfileMac00DispType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.34.1.31.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::cmFlowPointCpdProfileMac00DispType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.34.1.31.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmFlowPointCpdProfileMac00DispType OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.34cmFlowPointCpdProfileTableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.34.1cmFlowPointCpdProfileEntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.34.1.31cmFlowPointCpdProfileMac00DispTypeCM-FACILITY-MIB