CM-FACILITY-MIB :: cmFlowPointCpdProfileGVRPDispType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBcmFlowPointCpdProfileGVRPDispType

cmFlowPointCpdProfileGVRPDispType

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::cmFlowPointCpdProfileGVRPDispType

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.34.1.26

Node type: OBJECT-TYPE

Type: CmControlProtocolDispType

Access: read-write

Description: Control Protocol Disposition for GARP VLAN Registration Protocol. MAC Address (01:80:C2:00:00:22).

What is cmFlowPointCpdProfileGVRPDispType?

Specifies how flow points handle GARP VLAN Registration Protocol frames for dynamic VLAN registration. Determines whether GVRP packets are forwarded or dropped. Operators configure this to control VLAN discovery and dynamic configuration.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.34.1.26
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmFlowPointCpdProfileGVRPDispType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.34.1.26.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::cmFlowPointCpdProfileGVRPDispType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.34.1.26.1 s <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cmFlowPointCpdProfileGVRPDispType.1

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmFlowPointCpdProfileGVRPDispType OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.34cmFlowPointCpdProfileTableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.34.1cmFlowPointCpdProfileEntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.34.1.26cmFlowPointCpdProfileGVRPDispTypeCM-FACILITY-MIB