CM-FACILITY-MIB :: cmFlowCpdV2VtpDispType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBcmFlowCpdV2VtpDispType

cmFlowCpdV2VtpDispType

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::cmFlowCpdV2VtpDispType

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.14.1.7

Node type: OBJECT-TYPE

Type: CmControlProtocolDispType

Access: read-write

Description: Control Protocol Disposition for VTP (VLAN Trunking Protocol). MAC Address (01:00:0C:CC:CC:CC), Ethertype(0x2003).

What is cmFlowCpdV2VtpDispType?

CpdV2VtpDispType is a read-write setting on the configured flow (a per-EVC traffic instance rather than a whole physical facility) that selects how VLAN Trunking Protocol (VTP) control frames (MAC 01:00:0C:CC:CC:CC, Ethertype 0x2003) are disposed of when they reach this NE — typically processed locally, dropped, passed through untouched, or tunneled across the network via L2PT. If this facility sits between two switches that share VTP domain configuration, the disposition must allow pass-through or VLAN database synchronization between them will silently stop working. On a flow carrying a particular customer's EVC across the network, an administrator would set this object to peer, drop, pass-through, or tunnel VLAN Trunking Protocol (VTP) frames depending on whether this facility should terminate, block, forward, or L2PT-encapsulate that traffic.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.14.1.7
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmFlowCpdV2VtpDispType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.14.1.7.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::cmFlowCpdV2VtpDispType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.14.1.7.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmFlowCpdV2VtpDispType OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.14cmFlowCpdV2TableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.14.1cmFlowCpdV2EntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.14.1.7cmFlowCpdV2VtpDispTypeCM-FACILITY-MIB