All MIBs › CM-FACILITY-MIB › cmFlowCpdV2EfmOamDispType
cmFlowCpdV2EfmOamDispType
Module: CM-FACILITY-MIB
OID (symbolic): CM-FACILITY-MIB::cmFlowCpdV2EfmOamDispType
OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.14.1.18
Node type: OBJECT-TYPE
Type: CmControlProtocolDispType
Access: read-write
Description: Control Protocol Disposition for IEEE 802.3ah EFM OAM. MAC Address (01:80:C2:00:00:03), Ethertype (0x8809), Subtype(03).
What is cmFlowCpdV2EfmOamDispType?
CpdV2EfmOamDispType is a read-write setting on the configured flow (a per-EVC traffic instance rather than a whole physical facility) that selects how IEEE 802.3ah Ethernet-in-the-First-Mile (EFM) OAM control frames (MAC 01:80:C2:00:00:03, Ethertype 0x8809, subtype 03) are disposed of when they reach this NE — typically processed locally, dropped, passed through untouched, or tunneled across the network via L2PT. EFM OAM disposition needs to be set to peer/process locally when this facility itself terminates 802.3ah link monitoring, or to pass-through when OAM discovery must run end-to-end past this device. On a flow carrying a particular customer's EVC across the network, an administrator would set this object to peer, drop, pass-through, or tunnel IEEE 802.3ah Ethernet-in-the-First-Mile (EFM) OAM frames depending on whether this facility should terminate, block, forward, or L2PT-encapsulate that traffic.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.14.1.18 snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmFlowCpdV2EfmOamDispType
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.14.1.18.1 snmpget -v2c -c public <target> CM-FACILITY-MIB::cmFlowCpdV2EfmOamDispType.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.14.1.18.1 s <value>
Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmFlowCpdV2EfmOamDispType OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.12 | fsp150cm | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.12.4 | cmFacilityMIB | CM-FACILITY-MIB |
| 1.3.6.1.4.1.2544.1.12.4.1 | cmFacilityObjects | CM-FACILITY-MIB |
| 1.3.6.1.4.1.2544.1.12.4.1.14 | cmFlowCpdV2Table | CM-FACILITY-MIB |
| 1.3.6.1.4.1.2544.1.12.4.1.14.1 | cmFlowCpdV2Entry | CM-FACILITY-MIB |
| 1.3.6.1.4.1.2544.1.12.4.1.14.1.18 | cmFlowCpdV2EfmOamDispType | CM-FACILITY-MIB |