CM-FACILITY-MIB :: cmFlowCpdV2CustomerLLDPDispType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBcmFlowCpdV2CustomerLLDPDispType

cmFlowCpdV2CustomerLLDPDispType

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::cmFlowCpdV2CustomerLLDPDispType

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.14.1.48

Node type: OBJECT-TYPE

Type: CmControlProtocolDispType

Access: read-write

Description: LLDP (Link Layer Discovery Protocol) Customer Bridge Disposition type.

What is cmFlowCpdV2CustomerLLDPDispType?

CpdV2CustomerLLDPDispType is a read-write setting on the configured flow (a per-EVC traffic instance rather than a whole physical facility) that selects how the LLDP Customer Bridge scope control frames are disposed of when they reach this NE — typically processed locally, dropped, passed through untouched, or tunneled across the network via L2PT. Setting this to pass-through lets a customer's own LLDP neighbor-discovery frames traverse the carrier facility end-to-end without the provider's own bridge intercepting them. On a flow carrying a particular customer's EVC across the network, a carrier offering a transparent Ethernet private line would set this to pass-through so the two ends of a customer's LLDP session see each other unmodified.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.14.1.48
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmFlowCpdV2CustomerLLDPDispType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.14.1.48.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::cmFlowCpdV2CustomerLLDPDispType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.14.1.48.1 s <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cmFlowCpdV2CustomerLLDPDispType.1

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmFlowCpdV2CustomerLLDPDispType OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.14cmFlowCpdV2TableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.14.1cmFlowCpdV2EntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.14.1.48cmFlowCpdV2CustomerLLDPDispTypeCM-FACILITY-MIB