CM-FACILITY-MIB :: cmFlowCpdDispType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBcmFlowCpdDispType

cmFlowCpdDispType

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::cmFlowCpdDispType

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.5.1.4

Node type: OBJECT-TYPE

Type: CmControlProtocolDispType

Access: read-write

Description: This enables specification of disposion type of CPD Filter.

What is cmFlowCpdDispType?

This read-write CmControlProtocolDispType sets how the device disposes of frames matching a flow's CPD filter entry, such as passing, dropping, or tunneling them. An admin needs to configure this correctly because control-protocol frames like BPDUs or CDP that leak across a customer-facing flow can trigger spanning-tree topology changes or leak internal network information if not filtered appropriately. For example, on a flow carrying a business Ethernet service, an admin might set cmFlowCpdDispType to drop for a filter row matching CDP so the customer's switch never sees the carrier's discovery frames.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.5.1.4
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmFlowCpdDispType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.5.1.4.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::cmFlowCpdDispType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.5.1.4.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmFlowCpdDispType OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.5cmFlowCpdTableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.5.1cmFlowCpdEntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.5.1.4cmFlowCpdDispTypeCM-FACILITY-MIB