CM-FACILITY-MIB :: cmEthernetTrafficPortIngressPushPVIDEnabled

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBcmEthernetTrafficPortIngressPushPVIDEnabled

cmEthernetTrafficPortIngressPushPVIDEnabled

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::cmEthernetTrafficPortIngressPushPVIDEnabled

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.27.1.66

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: This object allows to specify whether cmEthernetTrafficPortPortVlanId value will be PUSHed on untagged frames or not in the ingress direction. This object is only applicable for connection-oriented, evpl service type.

What is cmEthernetTrafficPortIngressPushPVIDEnabled?

cmEthernetTrafficPortIngressPushPVIDEnabled is a read-write boolean specifying whether this port's configured PVID value is pushed onto untagged ingress frames, applicable only for connection-oriented EVPL service. An administrator enables this when untagged customer frames need to be tagged with a specific VLAN internally so they can be carried alongside other tagged services through the same EVPL infrastructure. For example, a customer sending untagged Ethernet frames into an EVPL service that must be identified by a specific internal VLAN would have this object enabled so the port's PVID is pushed onto those frames on ingress.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.27.1.66
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmEthernetTrafficPortIngressPushPVIDEnabled

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.27.1.66.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::cmEthernetTrafficPortIngressPushPVIDEnabled.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.27.1.66.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmEthernetTrafficPortIngressPushPVIDEnabled OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.27cmEthernetTrafficPortTableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.27.1cmEthernetTrafficPortEntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.27.1.66cmEthernetTrafficPortIngressPushPVIDEnabledCM-FACILITY-MIB