CM-FACILITY-MIB :: cmEthernetNetPortCpdV2SSMDispType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBcmEthernetNetPortCpdV2SSMDispType

cmEthernetNetPortCpdV2SSMDispType

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::cmEthernetNetPortCpdV2SSMDispType

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.15.1.19

Node type: OBJECT-TYPE

Type: CmControlProtocolDispType

Access: read-write

Description: Control Protocol Disposition for Sync Status Messages. MAC Address (01:80:C2:00:00:02), Ethertype (0x19A7), Subtype(0A).

What is cmEthernetNetPortCpdV2SSMDispType?

CpdV2SSMDispType is a read-write setting on the Ethernet network-facing (NNI/trunk) port that selects how Synchronization Status Message (SSM) slow-protocol control frames (MAC 01:80:C2:00:00:02, Ethertype 0x19A7, subtype 0A) are disposed of when they reach this NE — typically processed locally, dropped, passed through untouched, or tunneled across the network via L2PT. Getting this wrong means the network's timing-quality signaling either gets silently eaten at this box or leaks onto a segment that shouldn't see it, undermining clock-quality selection downstream. On the network-facing trunk port linking to the next carrier NE, an administrator would peer SSM locally if this NE itself needs to read/relay the synchronization quality level, rather than dropping frames meant to inform its clock source selection.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.15.1.19
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmEthernetNetPortCpdV2SSMDispType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.15.1.19.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::cmEthernetNetPortCpdV2SSMDispType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.15.1.19.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmEthernetNetPortCpdV2SSMDispType OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.15cmEthernetNetPortCpdV2TableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.15.1cmEthernetNetPortCpdV2EntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.15.1.19cmEthernetNetPortCpdV2SSMDispTypeCM-FACILITY-MIB