CM-FACILITY-MIB :: cmEthernetNetPortCpdV2PauseDispType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBcmEthernetNetPortCpdV2PauseDispType

cmEthernetNetPortCpdV2PauseDispType

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::cmEthernetNetPortCpdV2PauseDispType

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.15.1.15

Node type: OBJECT-TYPE

Type: CmControlProtocolDispType

Access: read-write

Description: Control Protocol Disposition for IEEE 802.3x Flow Control (PAUSE frames).

What is cmEthernetNetPortCpdV2PauseDispType?

This object controls how the system handles IEEE 802.3x Flow Control (PAUSE) frames on an Ethernet network port. An operator configures this to either pass, drop, or otherwise manage PAUSE frames to prevent network congestion or to maintain compatibility with flow-control protocols. Setting this disposition type affects how the port responds to backpressure signals from directly connected devices.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.15.1.15
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmEthernetNetPortCpdV2PauseDispType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.15.1.15.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::cmEthernetNetPortCpdV2PauseDispType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.15.1.15.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmEthernetNetPortCpdV2PauseDispType OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.15cmEthernetNetPortCpdV2TableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.15.1cmEthernetNetPortCpdV2EntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.15.1.15cmEthernetNetPortCpdV2PauseDispTypeCM-FACILITY-MIB