All MIBs › CM-FACILITY-MIB › cmEthernetAccPortN2APopPVIDEnabled
cmEthernetAccPortN2APopPVIDEnabled
Module: CM-FACILITY-MIB
OID (symbolic): CM-FACILITY-MIB::cmEthernetAccPortN2APopPVIDEnabled
OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.1.1.86
Node type: OBJECT-TYPE
Type: TruthValue
Access: read-write
Description: This object allows to specify whether cmEthernetAccPortPortVlanId value will be POPed in the Network to Access direction. This object is only applicable for connection-oriented, evpl service type.
What is cmEthernetAccPortN2APopPVIDEnabled?
This read-write TruthValue, applicable only for connection-oriented EVPL service, specifies whether the port's configured VLAN Id gets popped, or stripped, from frames traveling in the network-to-access direction. It complements the push setting to return traffic to the customer untagged. For example, an administrator enables Pop so return traffic destined to the customer has its VLAN tag removed before delivery.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.1.1.86 snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmEthernetAccPortN2APopPVIDEnabled
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.1.1.86.1 snmpget -v2c -c public <target> CM-FACILITY-MIB::cmEthernetAccPortN2APopPVIDEnabled.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.1.1.86.1 s <value>
Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmEthernetAccPortN2APopPVIDEnabled OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.12 | fsp150cm | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.12.4 | cmFacilityMIB | CM-FACILITY-MIB |
| 1.3.6.1.4.1.2544.1.12.4.1 | cmFacilityObjects | CM-FACILITY-MIB |
| 1.3.6.1.4.1.2544.1.12.4.1.1 | cmEthernetAccPortTable | CM-FACILITY-MIB |
| 1.3.6.1.4.1.2544.1.12.4.1.1.1 | cmEthernetAccPortEntry | CM-FACILITY-MIB |
| 1.3.6.1.4.1.2544.1.12.4.1.1.1.86 | cmEthernetAccPortN2APopPVIDEnabled | CM-FACILITY-MIB |