CM-FACILITY-MIB :: cmEthernetAccPortLinkLossFwdSignalType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBcmEthernetAccPortLinkLossFwdSignalType

cmEthernetAccPortLinkLossFwdSignalType

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::cmEthernetAccPortLinkLossFwdSignalType

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.1.1.42

Node type: OBJECT-TYPE

Type: CmLinkLossFwdSignalType

Access: read-write

Description: This object allows definition of the link loss forwarding signalling type. This is applicable only if cmEthernetAccPortLinkLossFwdEnabled is enabled. This object is applicable only for FSP150CM Release 3.1. This object is deprecated henceforth. Link Loss signalling will be supported using the object cmEthernetAccPortLinkLossFwdTxActionType.

What is cmEthernetAccPortLinkLossFwdSignalType?

This read-write CmLinkLossFwdSignalType, deprecated and applicable only to FSP150CM Release 3.1, originally selected the signaling type used for link loss forwarding on the Ethernet Access Port. Its function has been superseded by the newer cmEthernetAccPortLinkLossFwdTxActionType object. For example, on a legacy FSP150CM R3.1 unit an administrator still reads this value to confirm the current signaling type before migrating the configuration to the replacement object.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.1.1.42
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmEthernetAccPortLinkLossFwdSignalType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.1.1.42.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::cmEthernetAccPortLinkLossFwdSignalType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.1.1.42.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmEthernetAccPortLinkLossFwdSignalType OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.1cmEthernetAccPortTableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.1.1cmEthernetAccPortEntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.1.1.42cmEthernetAccPortLinkLossFwdSignalTypeCM-FACILITY-MIB