CM-FACILITY-MIB :: cmEthernetAccPortCpdV2UplinkFastDispType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBcmEthernetAccPortCpdV2UplinkFastDispType

cmEthernetAccPortCpdV2UplinkFastDispType

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::cmEthernetAccPortCpdV2UplinkFastDispType

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.13.1.10

Node type: OBJECT-TYPE

Type: CmControlProtocolDispType

Access: read-write

Description: Control Protocol Disposition for STP UplinkFast. MAC Address (01:00:0C:CD:CD:CD), Ethertype(0x200A).

What is cmEthernetAccPortCpdV2UplinkFastDispType?

This read-write CmControlProtocolDispType object sets the Control Protocol Disposition specifically for STP UplinkFast frames, identified by MAC address 01:00:0C:CD:CD:CD and Ethertype 0x200A, on an Ethernet Access Port. Admins configure this to control propagation of Cisco's UplinkFast fast-convergence signaling across the service boundary, similar in intent to the other Cisco-specific STP extension filters. For example, an admin who doesn't want a customer's UplinkFast signaling to interact with carrier-side spanning tree would set cmEthernetAccPortCpdV2UplinkFastDispType to drop on that customer's access port.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.13.1.10
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmEthernetAccPortCpdV2UplinkFastDispType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.13.1.10.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::cmEthernetAccPortCpdV2UplinkFastDispType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.13.1.10.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmEthernetAccPortCpdV2UplinkFastDispType OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.13cmEthernetAccPortCpdV2TableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.13.1cmEthernetAccPortCpdV2EntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.13.1.10cmEthernetAccPortCpdV2UplinkFastDispTypeCM-FACILITY-MIB