CM-FACILITY-MIB :: cmEthernetAccPortCpdV2Mac09DispType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBcmEthernetAccPortCpdV2Mac09DispType

cmEthernetAccPortCpdV2Mac09DispType

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::cmEthernetAccPortCpdV2Mac09DispType

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.13.1.39

Node type: OBJECT-TYPE

Type: CmControlProtocolDispType

Access: read-write

Description: MAC Address 01:80:C2:00:00:09 Disposition type.

What is cmEthernetAccPortCpdV2Mac09DispType?

This object controls how the access port handles Ethernet frames destined to the multicast MAC address 01:80:C2:00:00:09, which is reserved for control plane protocols. The disposition type determines whether the frames are forwarded, trapped to the management system, or discarded. Operators configure this to manage control protocol traffic and ensure proper handling of management and signaling frames on access ports.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.13.1.39
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmEthernetAccPortCpdV2Mac09DispType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.13.1.39.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::cmEthernetAccPortCpdV2Mac09DispType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.13.1.39.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmEthernetAccPortCpdV2Mac09DispType OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.13cmEthernetAccPortCpdV2TableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.13.1cmEthernetAccPortCpdV2EntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.13.1.39cmEthernetAccPortCpdV2Mac09DispTypeCM-FACILITY-MIB