CM-FACILITY-MIB :: cmEthernetAccPortCpdV2LACPMarkerDispType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBcmEthernetAccPortCpdV2LACPMarkerDispType

cmEthernetAccPortCpdV2LACPMarkerDispType

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::cmEthernetAccPortCpdV2LACPMarkerDispType

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.13.1.17

Node type: OBJECT-TYPE

Type: CmControlProtocolDispType

Access: read-write

Description: Control Protocol Disposition for IEEE 802.3ad Marker Protocol. MAC Address (01:80:C2:00:00:03), Ethertype (0x8809), Subtype(02).

What is cmEthernetAccPortCpdV2LACPMarkerDispType?

This read-write CmControlProtocolDispType object sets the Control Protocol Disposition specifically for IEEE 802.3ad Marker Protocol frames, identified by MAC address 01:80:C2:00:00:03, Ethertype 0x8809, and subtype 02, on an Ethernet Access Port. Admins configure this when deciding how link-aggregation Marker protocol frames (used to verify frame-distribution consistency in a LAG) should be treated at the access-port boundary, distinct from the closely related EFM OAM filter sharing the same MAC/Ethertype but a different subtype. For example, on an access port that is part of a customer-facing link aggregation group, an admin would set cmEthernetAccPortCpdV2LACPMarkerDispType to pass so Marker protocol frames needed for proper LAG verification aren't inadvertently dropped.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.13.1.17
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmEthernetAccPortCpdV2LACPMarkerDispType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.13.1.17.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::cmEthernetAccPortCpdV2LACPMarkerDispType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.13.1.17.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmEthernetAccPortCpdV2LACPMarkerDispType OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.13cmEthernetAccPortCpdV2TableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.13.1cmEthernetAccPortCpdV2EntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.13.1.17cmEthernetAccPortCpdV2LACPMarkerDispTypeCM-FACILITY-MIB