CM-FACILITY-MIB :: cmEthernetAccPortCpdV2EfmOamDispType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBcmEthernetAccPortCpdV2EfmOamDispType

cmEthernetAccPortCpdV2EfmOamDispType

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::cmEthernetAccPortCpdV2EfmOamDispType

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.13.1.18

Node type: OBJECT-TYPE

Type: CmControlProtocolDispType

Access: read-write

Description: Control Protocol Disposition for IEEE 802.3ah EFM OAM. MAC Address (01:80:C2:00:00:03), Ethertype (0x8809), Subtype(03).

What is cmEthernetAccPortCpdV2EfmOamDispType?

This read-write CmControlProtocolDispType object sets the Control Protocol Disposition specifically for IEEE 802.3ah EFM OAM frames, identified by MAC address 01:80:C2:00:00:03, Ethertype 0x8809, and subtype 03, on an Ethernet Access Port. Admins configure this to control whether EFM OAM frames (used for the fault-signaling and loopback features documented elsewhere in this MIB) are allowed to pass across this specific access port, distinct from the Marker protocol sharing the same MAC/Ethertype but a different subtype. For example, if a customer's own equipment should not be able to exchange EFM OAM frames with the carrier's network on a given access port, an admin would set cmEthernetAccPortCpdV2EfmOamDispType to drop so those OAMPDUs are filtered out at that port.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.13.1.18
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::cmEthernetAccPortCpdV2EfmOamDispType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.13.1.18.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::cmEthernetAccPortCpdV2EfmOamDispType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.4.1.13.1.18.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::cmEthernetAccPortCpdV2EfmOamDispType OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.13cmEthernetAccPortCpdV2TableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.13.1cmEthernetAccPortCpdV2EntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.13.1.18cmEthernetAccPortCpdV2EfmOamDispTypeCM-FACILITY-MIB