CM-FACILITY-MIB :: clk16PortGroupSquelchQL

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-FACILITY-MIBclk16PortGroupSquelchQL

clk16PortGroupSquelchQL

Module: CM-FACILITY-MIB

OID (symbolic): CM-FACILITY-MIB::clk16PortGroupSquelchQL

OID (numeric): 1.3.6.1.4.1.2544.1.12.4.1.80.1.9

Node type: OBJECT-TYPE

Type: SSMQualityLevel

Access: read-only

Description: This object allows to set the Squelch QL for the 10MHz port. This value is used when f310MHzClockPortSquelchControl is squelch-ql. The Squelch QL is used to determine whether or not to squelch the output of the TOD port. If the system's QL is lower than the Squelch QL, the output is squelched.

What is clk16PortGroupSquelchQL?

This OID sets a quality threshold for a 10 MHz timing output port, suppressing the output if the system's time quality drops below this level. Squelching poor-quality timing prevents dependent equipment from locking to unreliable time references. A timing engineer adjusts this when equipment downstream requires a minimum time accuracy level.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.80.1.9
snmpwalk -v2c -c public <target> CM-FACILITY-MIB::clk16PortGroupSquelchQL

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.4.1.80.1.9.1
snmpget -v2c -c public <target> CM-FACILITY-MIB::clk16PortGroupSquelchQL.1

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-FACILITY-MIB::clk16PortGroupSquelchQL OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.4cmFacilityMIBCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1cmFacilityObjectsCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.80clk16PortGroupTableCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.80.1clk16PortGroupEntryCM-FACILITY-MIB
1.3.6.1.4.1.2544.1.12.4.1.80.1.9clk16PortGroupSquelchQLCM-FACILITY-MIB