| OID symbolic | OID numeric | Type | Access | Description |
| ciscoWebExMeetingMIB | 1.3.6.1.4.1.9.9.809 | | | Cisco WebEx Collaboration Host is a
software-only system, with hardware independence
a key goal. To that end, it will be designed
to work only on a VMware virtual platform.
Cisco WebEx Collaboration Host consists of
various components that allow user to
collaborate using web, video, and audio in
a meeting.
These host components are as follows:
i) Web service component -
serves the web application
to allow user to schedule and start
the meeting
ii) Web admin service component -
serves the web application
to allow user to configure,
manage, and monitor the whole
collaboration platform.
iii) meeting service component -
serves the WebEx meetingroom application
to allow user to share or view, and perform
in-session control for the meeting and
participants.
iv) multi-media service component -
serves the VOIP conference application
for video and audio.
v) telephony service component -
serves the in-session control for the
audio participants.
vi) network-based recording service component -
serves to record meeting.
Each service component except i and ii as described
above could be clustered to run on multiple systems.
Each cluster is related to a zone in WebEx
terminology. A group of service components that
are deployed to make up various zone with
failover capability is known as a meeting domain.
This MIB provides the common objects that will be
monitored by WebEx web monitoring system to indicate
performance and capacity issues.
This MIB covers following
1. System Resource Utilization
2. Notification resources usage changes |
| ciscoWebExMeetingMIBNotifs | 1.3.6.1.4.1.9.9.809.0 | | | |
| NTF cwCommSystemResourceUsageNormalEvent | 1.3.6.1.4.1.9.9.809.0.1 | | | This notification indicates that some system resource usage
changes to the normal status. System could send out this
notification once one of the following cases happens:
1. The cwCommCPUUsage value of one CPU changes to be less than
the value of pre-defined CPU Minor Threshold.
2. The value of cwCommMEMUsage changes to be less than
the value of pre-defined MEM Minor Threshold.
3. The value of cwCommMEMSwapUsage changes to be less than
in the value of pre-defined MEM SwapMinor Threshold.
4. The value of cwCommFileUsage changes to be less than
the value of pre-defined File Minor Threshold.
5. The value of cwCommDiskUsage on one disk changes to be
less than the value of pre-defined Disk Minor Threshold. |
| NTF cwCommSystemResourceUsageMinorEvent | 1.3.6.1.4.1.9.9.809.0.2 | | | This notification indicates that some system resource usage
changes to the minor status. System could send out this
notification once one of the following cases happens:
1. The cwCommCPUUsage value of one CPU changes to be larger
than or equal to the value of pre-defined CPU Minor Threshold
and be less than the value of cwCommCPUMajorThreshold.
2. The cwCommMEMUsage value changes to be larger than or equal
to the value of the pre-defined MEM Minor Threshold and be
less than the value of pre-defined MEM Major Threshold.
3. The cwCommMEMSwapUsage value changes to be larger than or
equal to the value of pre-defined MEM Swap Minor Threshold and
be less than the value of pre-defined MEM Swap Major
Threshold.
4. The cwCommFileUsage value changes to be larger than or
equal to the value of pre-defined File Minor Threshold and be
less than the value of pre-defined File Major Threshold.
5. The cwCommDiskUsage value of one disk changes to be larger
than or equal to the value of pre-defined Disk Minor Threshold
and be less than the value of pre-defined Disk Major
Threshold.
The minor notification means the system has some issues, the
system administrator needs to pay attention. |
| NTF cwCommSystemResourceUsageMajorEvent | 1.3.6.1.4.1.9.9.809.0.3 | | | This notification indicates that some system resource usage
changes to the major status. System could send out this
notification once one of the following cases happens:
1. The cwCommCPUUsage value of one CPU changes to be larger
than or equal to the value of pre-defined CPU Major Threshold.
2. The cwCommMEMUsage value changes to be larger than or equal
to the value of pre-defined MEM Major Threshold.
3. The cwCommMEMSwapUsage value changes to be larger than or
equal to the value of pre-defined MEM Swap Major Threshold.
4. The cwCommFileUsage value changes to be larger than or
equal to the value of pre-defined File Major Threshold.
5. The cwCommDiskUsage value of one disk changes to be larger
than or equal to the value of pre-defined Disk Major Threshold.
The major notification means the system is in critical status,
it needs the system administrator to take action immediately. |
| ciscoWebExMeetingMIBObjects | 1.3.6.1.4.1.9.9.809.1 | | | |
| ciscoWebExCommInfo | 1.3.6.1.4.1.9.9.809.1.1 | | | |
| STR cwCommSystemVersion | 1.3.6.1.4.1.9.9.809.1.1.1 | SnmpAdminString | read-only | This object provides the version of webEx system. |
| OID cwCommSystemObjectID | 1.3.6.1.4.1.9.9.809.1.1.2 | AutonomousType | read-only | This object provides the sysObjectID defined in
SNMPv2-MIB |
| ciscoWebExCommSystemResource | 1.3.6.1.4.1.9.9.809.1.2 | | | |
| cwCommCPUUsageObject | 1.3.6.1.4.1.9.9.809.1.2.1 | | | This object provides the system CPU usage. |
| G32 cwCommCPUTotalUsageEx | 1.3.6.1.4.1.9.9.809.1.2.1.1 | Gauge32 | read-only | This object provides the total percentage of CPU usage of a
host component.
The total CPU usage contains CPU user usage, CPU system
usage and CPU nice usage.
The CPU user time: CPU time spent in user space.
The CPU system time: CPU time spent in kernel space.
The CPU nice time: CPU time spent on low priority
processes. |
| G32 cwCommCPUUsageWindow | 1.3.6.1.4.1.9.9.809.1.2.1.2 | Gauge32 | read-write | This object controls the duration to wait before
sending notification (trap) after a CPU usage
threshold is crossed.
The notification is sent only if CPU usage crossed
a threshold level (normal/minor/major) and remains
in the new threshold level over the duration defined
in this window. |
| G32 cwCommCPUTotalNumber | 1.3.6.1.4.1.9.9.809.1.2.1.3 | Gauge32 | read-only | This object provides the total number of CPUs on the system. |
| cwCommCPUUsageTable | 1.3.6.1.4.1.9.9.809.1.2.1.4 | | not-accessible | A list of CPU usage registering on the device. |
| cwCommCPUUsageEntry | 1.3.6.1.4.1.9.9.809.1.2.1.4.1 | | not-accessible | An entry containing management information generic to
the CPU usage. |
| U32 cwCommCPUIndex | 1.3.6.1.4.1.9.9.809.1.2.1.4.1.1 | Unsigned32 | not-accessible | This object uniquely identifies a CPU in the table. Each CPU
has its own usage and breakdown values. |
| STR cwCommCPUName | 1.3.6.1.4.1.9.9.809.1.2.1.4.1.2 | SnmpAdminString | read-only | This object provides the CPU name.
For example, 'Intel(R) Xeon(TM) CPU 3.00GHz'. |
| G32 cwCommCPUUsage | 1.3.6.1.4.1.9.9.809.1.2.1.4.1.3 | Gauge32 | read-only | This object provides how many percentage of total CPU
resource is used.
Usually GHz is used for measuring CPU power. Since GHz
is too large for measuring some CPU usage categories,
KHz is used as the measuring unit. The system speed
(in KHz) multiply by the fraction of each CPU sections
(e.g. idle, nice, user, etc.) to get the CPU KHz of
each category; Khz is used as the unit for all the CPU
categories below. |
| G32 cwCommCPUUsageUser | 1.3.6.1.4.1.9.9.809.1.2.1.4.1.4 | Gauge32 | read-only | This object provides the CPU power executed in user mode. |
| G32 cwCommCPUUsageNice | 1.3.6.1.4.1.9.9.809.1.2.1.4.1.5 | Gauge32 | read-only | This object provides the CPU power executed on
low priority processes.
Nice is a program found on Unix and Linux. It directly
maps to a kernel call of the same name. nice is used to
invoke a utility or shell script with a particular
priority, thus giving the process more or less CPU time
than other processes. |
| G32 cwCommCPUUsageSystem | 1.3.6.1.4.1.9.9.809.1.2.1.4.1.6 | Gauge32 | read-only | This object provides the CPU power now is executed
in kernel mode. |
| G32 cwCommCPUUsageIdle | 1.3.6.1.4.1.9.9.809.1.2.1.4.1.7 | Gauge32 | read-only | This object provides the CPU power now is in idle status. |
| G32 cwCommCPUUsageIOWait | 1.3.6.1.4.1.9.9.809.1.2.1.4.1.8 | Gauge32 | read-only | This object provides the CPU power that is spending in
wait disk I/O to complete. |
| G32 cwCommCPUUsageIRQ | 1.3.6.1.4.1.9.9.809.1.2.1.4.1.9 | Gauge32 | read-only | This object provides the CPU usage that is spending
on handling interrupt request. |
| G32 cwCommCPUUsageSoftIRQ | 1.3.6.1.4.1.9.9.809.1.2.1.4.1.10 | Gauge32 | read-only | This object provides the CPU usage that is spending
on handling software interrupt request. |
| G32 cwCommCPUUsageSteal | 1.3.6.1.4.1.9.9.809.1.2.1.4.1.11 | Gauge32 | read-only | This object provides the CPU usage spent on other tasks
when running in a virtualized environment. |
| G32 cwCommCPUUsageCapacitySubTotal | 1.3.6.1.4.1.9.9.809.1.2.1.4.1.12 | Gauge32 | read-only | This object provides the current total CPU capacity. |
| CIS cwCommCPUMonitoringStatus | 1.3.6.1.4.1.9.9.809.1.2.1.5 | CiscoWebExCommSysResMonitoringStatus | read-only | This object provides the monitoring status of CPU resource.
closed (0) - Resource not available
open (1) - Resource available |
| G32 cwCommCPUCapacityTotal | 1.3.6.1.4.1.9.9.809.1.2.1.6 | Gauge32 | read-only | This object provides the overall CPU capacity. |
| cwCommMEMUsageObject | 1.3.6.1.4.1.9.9.809.1.2.2 | | | This object provides the system memory usage status. |
| G32 cwCommMEMUsage | 1.3.6.1.4.1.9.9.809.1.2.2.1 | Gauge32 | read-only | This object indicates the physical memory usage
of the virtual machine. |
| CIS cwCommMEMMonitoringStatus | 1.3.6.1.4.1.9.9.809.1.2.2.2 | CiscoWebExCommSysResMonitoringStatus | read-only | This object provides the monitoring status of memory resource.
closed (0) - Resource not available
open(1) - Resource available |
| G32 cwCommMEMTotal | 1.3.6.1.4.1.9.9.809.1.2.2.3 | Gauge32 | read-only | This object provides the total physical memory size of
the host |
| cwCommMEMSwapUsageObject | 1.3.6.1.4.1.9.9.809.1.2.3 | | | This object provides the system memory and swap memory usage. |
| G32 cwCommMEMSwapUsage | 1.3.6.1.4.1.9.9.809.1.2.3.1 | Gauge32 | read-only | This object provides the host's physical memory usage
and swap memory usage. |
| CIS cwCommMEMSwapMonitoringStatus | 1.3.6.1.4.1.9.9.809.1.2.3.2 | CiscoWebExCommSysResMonitoringStatus | read-only | This object provides the monitoring status of memory and
swap memory.
closed (0) - The memory and swap memory status
is available
open (1) - The memory and swap memory status
is not available |
| cwCommSysResourceNotificationObject | 1.3.6.1.4.1.9.9.809.1.2.4 | | | This object provides all the notification information. |
| IPt cwCommNotificationHostAddressType | 1.3.6.1.4.1.9.9.809.1.2.4.1 | InetAddressType | accessible-for-notify | This object represents the type of the network address made
available through cwCommNotificationHostAddress. |
| IP cwCommNotificationHostAddress | 1.3.6.1.4.1.9.9.809.1.2.4.2 | InetAddress | accessible-for-notify | This object provides the host IP address sent with the
notification. For example, '10.224.3.49'. |
| CIS cwCommNotificationResName | 1.3.6.1.4.1.9.9.809.1.2.4.3 | CiscoWebExCommSysResource | accessible-for-notify | This object provides the system resource name which
is sent with notification. It indicates the named
system resource has over pre-defined warning levels.
0. cwCommTtoalCPUUsage,
1. cwCommMemUsage,
2. cwCommMemSwapUsage,
3. open file descriptor (no MIB data)
4. one of the cwCommDiskTotal |
| U32 cwCommNotificationResValue | 1.3.6.1.4.1.9.9.809.1.2.4.4 | Unsigned32 | accessible-for-notify | This object provides the system resource usage value
with notification. |
| C32 cwCommNotificationSeqNum | 1.3.6.1.4.1.9.9.809.1.2.4.5 | Counter32 | accessible-for-notify | This object provides sequence number.
It's for tracking the order of the Notifications. |
| cwCommDiskUsageObject | 1.3.6.1.4.1.9.9.809.1.2.5 | | | This object provides the system's disk usage status. |
| G32 cwCommDiskUsageCount | 1.3.6.1.4.1.9.9.809.1.2.5.1 | Gauge32 | read-only | This object provides the count of how many
disks (e.g. local disk, remote disk,
meeting recording disk) available in the system. |
| cwCommDiskUsageTable | 1.3.6.1.4.1.9.9.809.1.2.5.2 | | not-accessible | A list of the detailed disk usage status at the partition level
for the host, registering on the device. |
| cwCommDiskUsageEntry | 1.3.6.1.4.1.9.9.809.1.2.5.2.1 | | not-accessible | An entry containing management information generic
to the disk usage. |
| U32 cwCommDiskUsageIndex | 1.3.6.1.4.1.9.9.809.1.2.5.2.1.1 | Unsigned32 | not-accessible | This object is an index of entries in the table that contain
management information generic to the disk usage. |
| STR cwCommDiskPartitionName | 1.3.6.1.4.1.9.9.809.1.2.5.2.1.2 | SnmpAdminString | read-only | this object provides the disk partition name.
For example, the partition '/opt', or '/dev' etc. |
| G32 cwCommDiskUsage | 1.3.6.1.4.1.9.9.809.1.2.5.2.1.3 | Gauge32 | read-only | This object provides the current disk usage on the host. |
| G32 cwCommDiskTotal | 1.3.6.1.4.1.9.9.809.1.2.5.2.1.4 | Gauge32 | read-only | This object provides the total disk space size of
this host. |
| CIS cwCommDiskMonitoringStatus | 1.3.6.1.4.1.9.9.809.1.2.5.3 | CiscoWebExCommSysResMonitoringStatus | read-only | This object provides the monitoring status of disk resource.
close (0) - the disk usage status is not available
open (1) - the disk usage status is available |
| ciscoWebExMeetingMIBConform | 1.3.6.1.4.1.9.9.809.2 | | | |
| cwCommMIBCompliances | 1.3.6.1.4.1.9.9.809.2.1 | | | |
| cwCommMIBCompliance | 1.3.6.1.4.1.9.9.809.2.1.1 | | | The compliance statement for entities which implement the
Cisco WebEx Common MIB. |
| cwCommMIBGroups | 1.3.6.1.4.1.9.9.809.2.2 | | | |
| ciscoWebExCommInfoGroup | 1.3.6.1.4.1.9.9.809.2.2.1 | | | This group is a collection of objects representing common
host information within Cisco WebEx. |
| ciscoWebExCommSystemResourceGroup | 1.3.6.1.4.1.9.9.809.2.2.2 | | | this group is a collection of objects representing
system resource information of the host. |
| ciscoWebExMeetingMIBNotifsGroup | 1.3.6.1.4.1.9.9.809.2.2.3 | | | This group defines the notifications generated by
this MIB module. |