| OID symbolic | OID numeric | Type | Access | Description |
| cctmActive | 1.3.6.1.4.1.9.9.165.1.1 | | | |
| CCT cctmActiveAttemptedECProtocol | 1.3.6.1.4.1.9.9.165.1.1.1.1.8 | CctmECProtocol | read-only | The initial modem error correction protocol attempted
during call negotiation.
The actual EC negotiated is in cctmActiveECProtocol. |
| CCT cctmActiveAttemptedModulation | 1.3.6.1.4.1.9.9.165.1.1.1.1.5 | CctmModulation | read-only | The initial modulation attempted when the modems began
negotiation. |
| CCT cctmActiveDataCompression | 1.3.6.1.4.1.9.9.165.1.1.1.1.11 | CctmDataCompression | read-only | The modem compression protocol selected for this call. |
| C32 cctmActiveECFramesResent | 1.3.6.1.4.1.9.9.165.1.1.1.1.31 | Counter32 | read-only | The count of total retransmitted error correction
data frames during the call. |
| C32 cctmActiveECLinkTimeouts | 1.3.6.1.4.1.9.9.165.1.1.1.1.32 | Counter32 | read-only | This counter provides the number of EC link protocol
timer expirations which have occurred during the call.
This corresponds to the T401 timer for LAPM and MNP.
These are distinct from normal 'keep alive' and
'window open' timeouts. |
| CCT cctmActiveECProtocol | 1.3.6.1.4.1.9.9.165.1.1.1.1.9 | CctmECProtocol | read-only | The modem error correction protocol negotiated for
this call.
The value of this object will be the same as reported
in cmProtocolUsed from CISCO-MODEM-MGMT-MIB
while the call is active. |
| cctmActiveEntry | 1.3.6.1.4.1.9.9.165.1.1.1.1 | | not-accessible | The information regarding a single call.
Entries are created and deleted in sync with the entries
in cctActiveTable, if the call utilizes modem service. |
| cctmActiveGroup | 1.3.6.1.4.1.9.9.165.3.2.2 | | | A collection of objects providing the
active call modem information. |
| CCT cctmActiveInitialModulation | 1.3.6.1.4.1.9.9.165.1.1.1.1.6 | CctmModulation | read-only | The initial negotiated modulation. |
| C32 cctmActiveLocalDownRateShifts | 1.3.6.1.4.1.9.9.165.1.1.1.1.17 | Counter32 | read-only | The count of locally initiated rate shifts to decrease
the data rate which were successful. |
| C32 cctmActiveLocalRetrains | 1.3.6.1.4.1.9.9.165.1.1.1.1.21 | Counter32 | read-only | The count of locally initiated retrains for the call.
Includes successfully completed retrains and those
which failed. |
| C32 cctmActiveLocalUpRateShiftsEx | 1.3.6.1.4.1.9.9.165.1.1.1.1.16 | Counter32 | read-only | The count of locally initiated rate shifts to increase
the data rate which were successful. |
| CCT cctmActiveModulation | 1.3.6.1.4.1.9.9.165.1.1.1.1.7 | CctmModulation | read-only | The current modulation for this call.
It is possible for retrains to result in the modulation
being renogiated during a call.
The value of this object will be the same as reported
in cmModulationSchemeUsed from CISCO-MODEM-MGMT-MIB
while the call is active. |
| U32 cctmActiveProjectedMaxRxRate | 1.3.6.1.4.1.9.9.165.1.1.1.1.1 | Unsigned32 | read-only | Maximum received rate local modem informs remote
modem it will support based on initial negotiations.
The remote modem will not attempt to transmit at
rates greater than what the local modem will accept.
The initial negotiated receive rate is in
cctActiveRxRate. |
| U32 cctmActiveProjectedMaxTxRate | 1.3.6.1.4.1.9.9.165.1.1.1.1.2 | Unsigned32 | read-only | Maximum rate the remote modem indicates it can
accept based on initial negotiations.
The local modem will not attempt to transmit at
rates above what the remote modem will accept.
The initial negotiated transmit rate is in
cctActiveTxRate. |
| C32 cctmActiveRateShiftFailures | 1.3.6.1.4.1.9.9.165.1.1.1.1.20 | Counter32 | read-only | The count of rate shift attempts which failed
to complete.
A failure to complete a rate renegotiation results in a
retrain attempt. |
| C32 cctmActiveRemoteDownRateShifts | 1.3.6.1.4.1.9.9.165.1.1.1.1.19 | Counter32 | read-only | The count of remotely initiated rate shifts to decrease
the data rate which were successful. |
| C32 cctmActiveRemoteRetrains | 1.3.6.1.4.1.9.9.165.1.1.1.1.22 | Counter32 | read-only | The count of remotely initiated retrains for the call.
Includes successfully completed retrains and those
which failed. |
| C32 cctmActiveRemoteUpRateShifts | 1.3.6.1.4.1.9.9.165.1.1.1.1.18 | Counter32 | read-only | The count of remotely initiated rate shifts to increase
the data rate which were successful. |
| C32 cctmActiveRetrainFailures | 1.3.6.1.4.1.9.9.165.1.1.1.1.23 | Counter32 | read-only | The count of retrains which failed to complete.
A failure to retrain results in another retrain
attempt. The call will terminate if too many
consecutive retrain failures occur. The consecutive
retrain failure threshold is system specific. |
| C32 cctmActiveRxCharLost | 1.3.6.1.4.1.9.9.165.1.1.1.1.33 | Counter32 | read-only | The number of characters received by the modem
but were dropped due to host buffer over run. |
| C32 cctmActiveRxECFrames | 1.3.6.1.4.1.9.9.165.1.1.1.1.26 | Counter32 | read-only | The total number of error correction data frames
received successfully.
This does not include damaged frames or control
frames. |
| C32 cctmActiveRxECFramesBad | 1.3.6.1.4.1.9.9.165.1.1.1.1.30 | Counter32 | read-only | The total error correction frames received during
the call which were determined to be bad. |
| C32 cctmActiveRxECNAKs | 1.3.6.1.4.1.9.9.165.1.1.1.1.28 | Counter32 | read-only | The total number of EC protocol negative acknowledgements
(NAK) received. |
| G32 cctmActiveRxHighWatermark | 1.3.6.1.4.1.9.9.165.1.1.1.1.12 | Gauge32 | read-only | The maximum receive data rate achieved during this call. |
| C32 cctmActiveRxLinkOctets | 1.3.6.1.4.1.9.9.165.1.1.1.1.24 | Counter32 | read-only | The total modem link level octets received during this
call. If using Error Correction and Data Compression, this
is the compressed data within the EC protocol frames. |
| G32 cctmActiveRxLowWatermark | 1.3.6.1.4.1.9.9.165.1.1.1.1.13 | Gauge32 | read-only | The minimum receive data rate during this call. |
| U32 cctmActiveRxRate | 1.3.6.1.4.1.9.9.165.1.1.1.1.3 | Unsigned32 | read-only | Current receive data rate for this call.
The value of this object will be the same as reported
in cmRXRate from CISCO-MODEM-MGMT-MIB while the call
is active. |
| BIT cctmActiveSupportedDC | 1.3.6.1.4.1.9.9.165.1.1.1.1.10 | Bits | read-only | The data compression protocols supported by the
calling modem.
This object is a bit map, with each bit representing
a different call type as identified below.
A 1-bit indicates the DC protocol is supported.
A 0-bit indicates the DC protocol is not supported.
Bit 0 - MNP5
Bit 1 - V.42bis in the receive direction
Bit 2 - V.42bis in the transmit direction
V.42bis may be separately available in Rx or Tx
directions. If all bits are zero, no data compression
is supported.
The particular compression selected by the answering
modem is reported in cctmActiveDataCompression. |
| cctmActiveTable | 1.3.6.1.4.1.9.9.165.1.1.1 | | not-accessible | This table contains entries for active calls in the
system which utilize modem resources.
It contains general modem session attributes and
statistics at the modem link and modem protocol layers.
The table extends the cctActiveTable, using the same
index, cctActiveCallId.
There are no entries for calls not requiring modem
services. |
| C32 cctmActiveTxECFrames | 1.3.6.1.4.1.9.9.165.1.1.1.1.27 | Counter32 | read-only | The total number of error correction data frames
transmitted successfully.
This does not include data frame resends or control
frames. |
| C32 cctmActiveTxECNAKs | 1.3.6.1.4.1.9.9.165.1.1.1.1.29 | Counter32 | read-only | The total number of EC protocol negative acknowledgements
(NAK) sent. |
| G32 cctmActiveTxHighWatermark | 1.3.6.1.4.1.9.9.165.1.1.1.1.14 | Gauge32 | read-only | The maximum transmit data rate achieved during this call. |
| C32 cctmActiveTxLinkOctets | 1.3.6.1.4.1.9.9.165.1.1.1.1.25 | Counter32 | read-only | The total modem link level octets transmitted during this
call. If using Error Correction and Data Compression, this
is the compressed data within the EC protocol frames. |
| G32 cctmActiveTxLowWatermark | 1.3.6.1.4.1.9.9.165.1.1.1.1.15 | Gauge32 | read-only | The minimum transmit data rate during this call. |
| U32 cctmActiveTxRate | 1.3.6.1.4.1.9.9.165.1.1.1.1.4 | Unsigned32 | read-only | Current transmit data rate for this call.
The value of this object will be the same as reported
in cmTXRate from CISCO-MODEM-MGMT-MIB while the call
is active. |
| cctmHistory | 1.3.6.1.4.1.9.9.165.1.2 | | | |
| CCT cctmHistoryAttemptedECProtocol | 1.3.6.1.4.1.9.9.165.1.2.1.1.8 | CctmECProtocol | read-only | The initial modem error correction protocol attempted
during call negotiation.
The actual EC negotiated is in cctmHistoryECProtocol. |
| CCT cctmHistoryAttemptedModulation | 1.3.6.1.4.1.9.9.165.1.2.1.1.5 | CctmModulation | read-only | The initial modulation attempted when the modems began
negotiation. |
| CCT cctmHistoryDataCompression | 1.3.6.1.4.1.9.9.165.1.2.1.1.11 | CctmDataCompression | read-only | The modem compression protocol selected for this call. |
| U32 cctmHistoryDisconnectReason | 1.3.6.1.4.1.9.9.165.1.2.1.1.34 | Unsigned32 | read-only | Code indicating the reason this call was
terminated. |
| STR cctmHistoryDisconnectReasonText | 1.3.6.1.4.1.9.9.165.1.2.1.1.35 | DisplayString | read-only | Text description of the disconnect reason indicated by
cctHistoryDisconnectReason.
Value is zero-length string if no text is available. |
| C32 cctmHistoryECFramesResent | 1.3.6.1.4.1.9.9.165.1.2.1.1.31 | Counter32 | read-only | The count of total retransmitted error correction
data frames during the call. |
| C32 cctmHistoryECLinkTimeouts | 1.3.6.1.4.1.9.9.165.1.2.1.1.32 | Counter32 | read-only | This counter provides the number of EC link protocol
timer expirations which have occurred during the call.
This corresponds to the T401 timer for LAPM and MNP.
These are distinct from normal 'keep alive' and
'window open' timeouts. |
| CCT cctmHistoryECProtocol | 1.3.6.1.4.1.9.9.165.1.2.1.1.9 | CctmECProtocol | read-only | The modem error correction protocol negotiated for
this call. |
| cctmHistoryEntry | 1.3.6.1.4.1.9.9.165.1.2.1.1 | | not-accessible | The information regarding a single terminated modem call.
Entries are created and deleted in sync with the entries
in cctHistoryTable, if the call utilized modem service. |
| CCT cctmHistoryFinalModulation | 1.3.6.1.4.1.9.9.165.1.2.1.1.7 | CctmModulation | read-only | The final modulation for this call.
It is possible for retrains to result in the modulation
being renogiated during a call. |
| U32 cctmHistoryFinalRxRate | 1.3.6.1.4.1.9.9.165.1.2.1.1.3 | Unsigned32 | read-only | Final receive data rate for this call.
The initial negotiated receive rate is in
cctHistoryRxRate. |
| U32 cctmHistoryFinalTxRate | 1.3.6.1.4.1.9.9.165.1.2.1.1.4 | Unsigned32 | read-only | Final transmit data rate for this call.
The initial negotiated transmit rate is in
cctHistoryTxRate. |
| cctmHistoryGroup | 1.3.6.1.4.1.9.9.165.3.2.3 | | | A collection of objects providing the
historical call modem information. |
| CCT cctmHistoryInitialModulation | 1.3.6.1.4.1.9.9.165.1.2.1.1.6 | CctmModulation | read-only | The initial negotiated modulation. |
| C32 cctmHistoryLocalDownRateShifts | 1.3.6.1.4.1.9.9.165.1.2.1.1.17 | Counter32 | read-only | The count of locally initiated rate shifts to decrease
the data rate which were successful. |
| C32 cctmHistoryLocalRetrains | 1.3.6.1.4.1.9.9.165.1.2.1.1.21 | Counter32 | read-only | The count of locally initiated retrains for the call.
Includes successfully completed retrains and those
which failed. |
| C32 cctmHistoryLocalUpRateShifts | 1.3.6.1.4.1.9.9.165.1.2.1.1.16 | Counter32 | read-only | The count of locally initiated rate shifts to increase
the data rate which were successful. |
| U32 cctmHistoryProjectedMaxRxRate | 1.3.6.1.4.1.9.9.165.1.2.1.1.1 | Unsigned32 | read-only | Maximum received rate local modem informs remote
modem it will support based on initial negotiations.
The remote modem will not attempt to transmit at
rates greater than what the local modem will accept.
The initial negotiated receive rate is in
cctHistoryRxRate. |
| U32 cctmHistoryProjectedMaxTxRate | 1.3.6.1.4.1.9.9.165.1.2.1.1.2 | Unsigned32 | read-only | Maximum rate the remote modem indicates it can
accept based on initial negotiations.
The local modem will not attempt to transmit at
rates above what the remote modem will accept.
The initial negotiated transmit rate is in
cctHistoryTxRate. |
| C32 cctmHistoryRateShiftFailures | 1.3.6.1.4.1.9.9.165.1.2.1.1.20 | Counter32 | read-only | The count of rate shift attempts which failed
to complete.
A failure to complete a rate renegotiation results in a
retrain attempt. |
| C32 cctmHistoryRemoteDownRateShifts | 1.3.6.1.4.1.9.9.165.1.2.1.1.19 | Counter32 | read-only | The count of remotely initiated rate shifts to decrease
the data rate which were successful. |
| C32 cctmHistoryRemoteRetrains | 1.3.6.1.4.1.9.9.165.1.2.1.1.22 | Counter32 | read-only | The count of remotely initiated retrains for the call.
Includes successfully completed retrains and those
which failed. |
| C32 cctmHistoryRemoteUpRateShifts | 1.3.6.1.4.1.9.9.165.1.2.1.1.18 | Counter32 | read-only | The count of remotely initiated rate shifts to increase
the data rate which were successful. |
| C32 cctmHistoryRetrainFailures | 1.3.6.1.4.1.9.9.165.1.2.1.1.23 | Counter32 | read-only | The count of retrains which failed to complete.
A failure to retrain results in another retrain
attempt. The call will terminate if too many
consecutive retrain failures occur. The consecutive
retrain failure threshold is system specific. |
| C32 cctmHistoryRxCharLost | 1.3.6.1.4.1.9.9.165.1.2.1.1.33 | Counter32 | read-only | The total number of characters received by the modem
but were dropped due to host buffer over run. |
| C32 cctmHistoryRxECFrames | 1.3.6.1.4.1.9.9.165.1.2.1.1.26 | Counter32 | read-only | The total number of error correction data frames received
successfully.
This does not include damaged frames or control frames. |
| C32 cctmHistoryRxECFramesBad | 1.3.6.1.4.1.9.9.165.1.2.1.1.30 | Counter32 | read-only | The total error correction frames received during
the call which were determined to be bad. |
| C32 cctmHistoryRxECNAKs | 1.3.6.1.4.1.9.9.165.1.2.1.1.28 | Counter32 | read-only | The total number of EC protocol negative acknowledgements
(NAK) received. |
| G32 cctmHistoryRxHighWatermark | 1.3.6.1.4.1.9.9.165.1.2.1.1.12 | Gauge32 | read-only | The maximum receive data rate achieved during this call. |
| C32 cctmHistoryRxLinkOctets | 1.3.6.1.4.1.9.9.165.1.2.1.1.24 | Counter32 | read-only | The total modem link level octets received during this
call. If using Error Correction and Data Compression, this
is the compressed data within the EC protocol frames. |
| G32 cctmHistoryRxLowWatermark | 1.3.6.1.4.1.9.9.165.1.2.1.1.13 | Gauge32 | read-only | The minimum receive data rate during this call. |
| BIT cctmHistorySupportedDC | 1.3.6.1.4.1.9.9.165.1.2.1.1.10 | Bits | read-only | The data compression protocols supported by the
calling modem.
This object is a bit map, with each bit representing
a different call type as identified below.
A 1-bit indicates the DC protocol is supported.
A 0-bit indicates the DC protocol is not supported.
Bit 0 - MNP5
Bit 1 - V.42bis in the receive direction
Bit 2 - V.42bis in the transmit direction
V.42bis may be separately available in Rx or Tx
directions. If all bits are zero, no data compression
is supported.
The particular compression selected by the answering
modem is reported in cctmHistoryDataCompression. |
| cctmHistoryTable | 1.3.6.1.4.1.9.9.165.1.2.1 | | not-accessible | This table provides information on terminated modem
calls.
It contains general modem session attributes and
statistics at the modem link and modem protocol layers.
The table extends the cctHistoryTable, using the same
index, cctHistoryIndex.
There are no entries for calls not requiring modem
services. |
| C32 cctmHistoryTxECFrames | 1.3.6.1.4.1.9.9.165.1.2.1.1.27 | Counter32 | read-only | The total number of error correction data frames
transmitted successfully.
This does not include data frame resends or control
frames. |
| C32 cctmHistoryTxECNAKs | 1.3.6.1.4.1.9.9.165.1.2.1.1.29 | Counter32 | read-only | The total number of EC protocol negative acknowledgements
(NAK) sent. |
| G32 cctmHistoryTxHighWatermark | 1.3.6.1.4.1.9.9.165.1.2.1.1.14 | Gauge32 | read-only | The maximum transmit data rate achieved during this call. |
| C32 cctmHistoryTxLinkOctets | 1.3.6.1.4.1.9.9.165.1.2.1.1.25 | Counter32 | read-only | The total modem link level octets transmitted during this
call. If using Error Correction and Data Compression, this
is the compressed data within the EC protocol frames. |
| G32 cctmHistoryTxLowWatermark | 1.3.6.1.4.1.9.9.165.1.2.1.1.15 | Gauge32 | read-only | The minimum transmit data rate during this call. |
| cctmMIBCompliance | 1.3.6.1.4.1.9.9.165.3.1.1 | | | The compliance statement for entities which
implement the CISCO CALL TRACKER MODEM MIB |
| cctmMIBCompliances | 1.3.6.1.4.1.9.9.165.3.1 | | | |
| cctmMIBConformance | 1.3.6.1.4.1.9.9.165.3 | | | |
| cctmMIBGroups | 1.3.6.1.4.1.9.9.165.3.2 | | | |
| cctmMIBNotificationPrefix | 1.3.6.1.4.1.9.9.165.2 | | | |
| cctmMIBNotifications | 1.3.6.1.4.1.9.9.165.2.0 | | | |
| cctmMIBObjects | 1.3.6.1.4.1.9.9.165.1 | | | |
| INT cctmXHistoryConstellation | 1.3.6.1.4.1.9.9.165.1.2.2.1.7 | INTEGER | read-only | Connection constellation size. |
| C32 cctmXHistoryECWindowClosures | 1.3.6.1.4.1.9.9.165.1.2.2.1.11 | Counter32 | read-only | The number of times the EC protocol window closed
without receiving an ACK or NAK from the remote modem.
A closure occurs when the maximum number of EC
information frames have been sent without receiving any
acknowledgement.
The window size is provided in cctmHistoryRxECWindowSize. |
| cctmXHistoryEntry | 1.3.6.1.4.1.9.9.165.1.2.2.1 | | not-accessible | The detailed information for a single terminated modem
call.
Entries are created and deleted in sync with the entries
in cctHistoryTable, if the call utilized modem service. |
| cctmXHistoryGroup | 1.3.6.1.4.1.9.9.165.3.2.4 | | | A collection of objects providing the
historical detailed call modem information. |
| U32 cctmXHistoryRxECInfoFrameSize | 1.3.6.1.4.1.9.9.165.1.2.2.1.1 | Unsigned32 | read-only | Negotiated maximum EC frame data payload size in
the receive direction.
LAPM distinguishes between Rx and Tx. MNP will have the
the same information frame size for Rx and Tx,
cctmHistoryTxECInfoFrameSize. |
| U32 cctmXHistoryRxECWindowSize | 1.3.6.1.4.1.9.9.165.1.2.2.1.3 | Unsigned32 | read-only | The EC protocol window size in units of frames in the
receive direction.
This is the maximum number of information frames sent from
remote modem that may be outstanding without receiving any
acknowledgement from the local modem.
If the EC protocol is LAPM, the Rx and Tx windows are
separately negotiated and may have different values. If
MNP, both windows are negotiated together and have the
same value for this object and cctHistoryTxECWindowSize. |
| I32 cctmXHistoryRxLevel | 1.3.6.1.4.1.9.9.165.1.2.2.1.5 | Integer32 | read-only | The final signal level in the receive direction for
applicable modulations. |
| cctmXHistoryTable | 1.3.6.1.4.1.9.9.165.1.2.2 | | not-accessible | This table provides additional, detailed information on
terminated modem calls.
It contains low level modem session attributes and
statistics at the modem link and modem protocol layers.
The table extends the cctHistoryTable, using the same
index, cctHistoryIndex. |
| U32 cctmXHistoryTxECInfoFrameSize | 1.3.6.1.4.1.9.9.165.1.2.2.1.2 | Unsigned32 | read-only | Negotiated maximum EC frame data payload size in
the transmit direction.
LAPM distinguishes between Rx and Tx. MNP will have the
the same information frame size for Tx and Rx,
cctmHistoryRxECInfoFrameSize. |
| U32 cctmXHistoryTxECWindowSize | 1.3.6.1.4.1.9.9.165.1.2.2.1.4 | Unsigned32 | read-only | The EC protocol window size in units of frames in the
transmit direction.
This is the maximum number of information frames sent from
local modem that may be outstanding without receiving any
acknowledgement from the remote modem.
If the EC protocol is LAPM, the Rx and Tx windows are
separately negotiated and may have different values. If
MNP, both windows are negotiated together and have the
same value for this object and cctHistoryRxECWindowSize. |
| I32 cctmXHistoryTxLevel | 1.3.6.1.4.1.9.9.165.1.2.2.1.6 | Integer32 | read-only | The final signal level in the transmit direction for
applicable modulations. |
| U32 cctmXHistoryV90ClientId | 1.3.6.1.4.1.9.9.165.1.2.2.1.10 | Unsigned32 | read-only | Client modem identification inferred from the V.90 DIL
training and sign patterns. |
| INT cctmXHistoryV90Failure | 1.3.6.1.4.1.9.9.165.1.2.2.1.9 | INTEGER | read-only | This object provides an interpretation of why V.90
modulation was not achieved.
noFailure(1) - V.90 was not attempted or it
was successful. The value of cctmXHistoryV90Status
will be notAttempted(1) or success(3) respectively.
clientNonPCM(2) - Client selected a non-PCM
connection due to PSTN properties.
clientFallback(3) - Client was unable to sustain
PCM due to PSTN properties and fellback to a
non-PCM connection.
serverV90Disabled(4) - Client attempted V.90 but
server modem was configured to disable V.90. |
| INT cctmXHistoryV90Status | 1.3.6.1.4.1.9.9.165.1.2.2.1.8 | INTEGER | read-only | This object indicates if V.90 modulation was attempted
during initial modem negotiation.
notAttempted(1) - Client modem did not attempt V.90
failure(2) - Client and server modems attempted
V.90, but were not successful
success(3) - Client and server modems successfully
negotiated V.90 during call setup. |
| ciscoCallTrackerModemMIB | 1.3.6.1.4.1.9.9.165 | | | This MIB module provides modem call related data for
tracking the progress and status of a call.
This module extends tables defined in the MIB module
ciscoCallTrackerMIB in CISCO-CALL-TRACKER-MIB. |